PubMed Health⌕ Search

Biomedical subjects

H E Horng

Publications and source records attributed to H E Horng.

3 recordsLinked to original sources

Designing optical-fiber modulators by using magnetic fluids.

To reduce interface loss between optical fibers and devices in telecommunication systems, the development of an optical-fiber-based device that can be fused directly with fibers is important. A novel optical modulator consisting of a bare fiber core surrounded by magnetic fluids instead of by a SiO2 cladding layer is proposed. Applying a magnetic field raises the refractive index of the magnetic fluid. Thus we can control the occurrence of total reflection at the interface between the fiber core and the magnetic fluid when light propagates along the fiber. As a result, the intensity of the outgoing light is modulated by variation in field strength. Details of the design, fabrication, and working properties of such a modulator are presented.

Journal Article↗

Magnetocardiography of animals in magnetically shielded environment with active compensation.

A high-Tc 1st-order electronic superconducting quantum interference device (SQUID) gradiometer system is constructed to study the magnetocardiogram (MCG) of rabbits in a moderately magnetically shielded environment with active compensation. In the noisy hospital environment, the noise cannot be completely reduced with the 1st-order gradiometer, therefore, a reference SQUID with active compensation was used to further reduce the noise level leaking into the room. The MCG system was equipped with a x-y translation bed. We used a low-pass filter with the cut off frequency at 44 Hz, a high-pass filter with the cut off frequency at 0.1 Hz and the 60 Hz notch filter to reduce the power line interference. The noise level of the 1st order gradiometer MCG system in this moderately magnetically shielded room was about 1 pT/square root of Hz1/2 at 1 Hz. The MCG of a normal rabbits was measured with this system and a MCG contour map and a current density distribution was constructed.

Animals↗

High-Tc SQUID magnetocardiography imaging system.

We set up a high-Tc SQUID system for magnetocardiography (MCG) in a moderately magnetically shielded room. The electronically balanced gradiometer consists of superconducting quantum interference device (SQUID) magnetometer. One reference SQUID was mounted above the sensing SQUID while the sensing SQUID is seated at the bottom of the cryostat. The baseline of the gradiometer is varied from 5 cm to 7 cm. The output of the MCG signal was filtered with the band pass filter (0.5 - 40 Hz) and the power-line filter. The MCG system was used to detect the magnetic signal of the human heart. Equivalent current sources were used to study the inverse problem.

Body Surface Potential Mapping↗