Calcified suture material in the breast after radiation therapy.

Of 335 women who underwent lumpectomy and radiation therapy for breast cancer, 42 subsequently developed calcifications. Particles typical of calcified suture material were identified in 21 of the 42 women (50%). No obvious calcified suture material was found in approximately 1,140 women of 38,000 (3%) who had undergone mammography after they had previously undergone breast biopsy for a benign lesion and thus had not undergone radiation therapy. Calcified suture material rarely develops in the nonirradiated breast, but it is common after radiation therapy and should not be confused with recurrent breast cancer. These calcifications are likely the result of delayed resorption of catgut sutures, which provide a matrix on which calcium can precipitate in a suitable local environment.

Breast Neoplasms

Interstitial lung disease: impact of postprocessing in digital storage phosphor imaging.

The ability to resolve the fine linear structures of interstitial lung disease is one measure of the limiting performance characteristics of an imaging system. Conventional screen-film radiography was compared with six algorithms of isodose storage phosphor digital radiography (0.2-mm x 10-bit pixel matrix) in the detection of interstitial lung abnormality documented by means of computed tomography in 40 patients with abnormalities and 25 healthy control subjects. Performance was evaluated with an analysis of variance (the Fisher paired comparison test; P less than .05) of the average receiver operating characteristic area of 2,730 observations by six readers. The moderately and the more markedly high-frequency edge-enhanced algorithms of storage phosphor digital radiographs were equivalent in performance to screen-film radiography. The default mode, low- and medium-frequency edge-enhanced algorithms, and gray scale reversed mode of storage phosphor digital radiography were inferior to screen-film radiography. The authors conclude that high-frequency edge-enhanced algorithms can perform as well as screen-film radiography in the detection of interstitial disease.

Algorithms

Detection of bullous lung disease: conventional radiography vs digital storage phosphor radiography.

The detection of fine linear contours and altered aeration are requirements for the radiologic diagnosis of bullous lung disease and are severe measures of the spatial and contrast resolution of chest imaging systems. We compared plain film radiography with five postprocessing algorithms of storage phosphor digital radiography (2144 x 1744 x 10 bit matrix with 0.2-mm pixel size) in the detection of CT-proved bullous lung disease (35 patients and 25 normal control subjects). Receiver-operating-characteristic analysis of 2160 observations by six interpreters was done to evaluate the observers' performance. By analysis of variance (p less than .05), we found that the default digital algorithm and the three edge-enhancing algorithms of high and medium frequencies performed less well than plain films did, but the differences fell short of statistical significance. Gray-scale reversal was the only digital algorithm that performed significantly less well than plain films did. We conclude that any differences between digital algorithms and plain films in the detection of bullous lung disease were too small to be detected in this study. Any difference between the two methods in providing clinically important, diagnostic information is likely to be insignificant.

Algorithms

Arthrography of the hand and wrist.

Arthrography of the wrist and hand is easy to perform, but accurate diagnosis requires meticulous technique and thorough knowledge of anatomy, pathology, and imaging principles. Wrist arthrography is usually performed to assess pain or instability after trauma; a complete examination usually requires injection of the RC, midcarpal, and distal radioulnar joints. Abnormalities that can be detected include interosseous ligament tears, capsular tears, triangular fibrocartilage perforations and separations, cartilaginous defects, loose bodies, and synovial abnormalities including adhesive capsulitis. Arthrography can also be useful in the evaluation of masses and scaphoid nonunion. Finger arthrography can demonstrate capsular injury, ligament tears, tendon derangement, volar plate disruption, cartilage abnormalities, fibrous ankylosis, synovial abnormalities, and ganglia. Tenography is seldom performed; this technique can delineate synovial abnormalities and can be used to evaluate tendon subluxation.

Arthrography

Subtle gastric abnormalities in a canine model: detection with low-dose imaging with storage phosphors and its equivalence to conventional radiography.

The authors compared low-dose (32% of standard exposure) storage phosphor digital imaging (system resolution: 0.2-mm pixels, 10 bits) with isovoltage 75-kVp conventional radiography (standard exposure) in the detection of subtle simulated gastric abnormalities by using air contrast barium studies. Subtle simulated abnormalities (3-7-mm polyps, 4-15-mm ulcer craters, 4-11-mm-diameter edema, and 11-12-mm linear ulcers) were produced in resected canine stomachs. Receiver operating characteristic analysis of 1,800 observations by six readers indicated that the digital images with and without high-frequency edge enhancement were equivalent to conventional radiographs (mean receiver operating characteristic areas [+/- standard deviation]: 0.76 +/- 0.06, 0.78 +/- 0.04, and 0.77 +/- 0.04, respectively). The accuracy of the diagnosis was equivalent for all three modalities. The following mean accuracies of negative and positive responses, respectively, for unenhanced digital, edge-enhanced digital, and conventional images were determined: 0.71 +/- 0.05 and 0.41 +/- 0.07, 0.71 +/- 0.04 and 0.51 +/- 0.09, and 0.68 +/- 0.04 and 0.43 +/- 0.05. It was concluded that low-dose storage phosphor air-contrast barium studies were equivalent to conventional radiography in the detection of subtle gastric abnormalities.

Animals

Septic emboli.

Explore the source record for details and available documents.

Humans