PubMed Health⌕ Search

Biomedical subjects

H E N Bersee

Publications and source records attributed to H E N Bersee.

5 recordsLinked to original sources

Adhesion performance of UHMWPE after different surface modification techniques.

A novel design of an ultra-high molecular weight polyethylene (UHMWPE) glenoid component has been proposed, based on adhesion to PMMA bone cement. However, due to the non-polar nature of UHMWPE, surface modification techniques are needed to obtain good adhesion and thus for the design to be viable. The aim of the study is to investigate adhesion of UHMWPE after different surface treatments. Three gas-phase surface modification techniques were investigated, namely UV/Ozone, corona discharge and radio frequency glow discharge plasma, as well as abrasion. The surface treated samples were examined using water contact angle, surface energy and roughness measurements, as well as single lap-joint shear testing using polymethylmethacrylate (PMMA) bone cement and methylmethacrylate (MMA) adhesive. The effect of aging on bonded samples has also been investigated. Corona and glow discharge treatments were found to activate the surface as shown by an increase in surface energy of over 100% in an order of less than a minute, corresponding to an increase in ultimate shear stress from 0.12 to 0.40 MPa. In contrast, UV/Ozone required exposure times in the order of minutes to have an effect that was still incomparable to the other gas-phase treatments examined. Abrasion produced slightly better adhesion properties for single lap-joints bonded with PMMA compared to the corona treatment. The best treatment was found to be a combined treatment of surface roughening for 10 s, and subsequently a 90 s glow discharge treatment, resulting in failure of the UHMWPE sheet material.

Adhesiveness↗

Effect of interface conditions between ultrahigh molecular weight polyethylene and polymethyl methacrylate bone cement on the mechanical behaviour of total shoulder arthroplasty.

The aim of this study was to investigate the effect of the interface condition between polymethyl methacrylate (PMMA) bone cement and the ultrahigh molecular weight (UHMWPE) glenoid component on cement stresses and glenoid component tilting in a finite element (FE) model. The background of this research is that most FE models assume bonding between the PMMA bone cement and the UHMWPE component, although it is very doubtful that this bonding is present. An FE model of a cemented glenoid component was developed and a joint compression force and subluxation force of 725 and 350 N respectively were applied. The maximal principal stresses in the cement layer ranged between 21.30 and 32.18 MPa. Glenoid component tilting ranged between 0.943 degrees and 0.513 degrees. It was found that the interface condition has a large effect on the maximal principal stresses and glenoid component tilting. Whether adhesion between the UHMWPE component and PMMA bone cement occurs is unknown beforehand and, as a result, design validation using the FE technique should be carried out both by using contact elements in combination with a coefficient of friction as well as by a full bonding at this interface.

Adhesiveness↗

Effect of glenoid component inclination on its fixation and humeral head subluxation in total shoulder arthroplasty.

OBJECTIVE: To investigate the effect of glenoid component inclination angle on the fixation of cemented glenoid-bone structures and humeral head subluxation. BACKGROUND: Results of shoulder replacements, in terms of glenoid component fixation and joint functionality, are bad and must be improved. Repeated glenoid component tilting, a result of eccentric contact forces harms glenoid component fixation. However, the effect of glenoid component inclination is unknown. METHODS: Keeled glenoid components are cemented into bone substitutes and positioned under inclination angles varying between -4.5 degrees and +4.5 degrees . For each inclination angle 5 glenoid specimens are loaded by a horizontal, constant joint compression force (725 (SD 10) N) and a vertical, superior directed subluxation force (shear force), cyclically varying between 0 and 350 (SD 1) N. After 200,000 load cycles, the upper and lower glenoid component rim-displacements are measured during 1500 additional load cycles by custom made displacement sensors. RESULTS: The maximal superior rim-displacement significantly increased and the minimal inferior rim-displacement dramatically decreased for increasing glenoid component inclination angles up to +4.5 degrees . Maximal ratio of subluxation force over compression force significantly decreased for increasing glenoid component inclination. CONCLUSIONS: According to this study, decreasing glenoid component inclination angle decreases glenoid component tilting and humeral head subluxation and the results can be used to improve total shoulder replacements. RELEVANCE: Better understanding of the effect of glenoid component inclination on glenoid component tilting and humeral head subluxation may be useful information for the surgeon to improve results of the total shoulder arthroplasty, when replacing the glenoid surface.

Arthroplasty↗

Effect of joint conformity on glenoid component fixation in total shoulder arthroplasty.

Results of shoulder replacements are inferior and must be improved. Two of the major problems of total shoulder replacements are loosening of cemented glenoid components and wear of polyethylene inlays of uncemented, metal-backed glenoid components. The aim of this study is to investigate the influence of joint conformity on glenoid-component fixation. Keeled glenoid components, with radii of curvature of 24, 25, or 29 mm, were cemented in bone substitutes, placed in a force-controlled test set-up, articulating against a 24 mm humeral head. They were loaded by a constant joint compression force (725 +/- 10 N) and a superior subluxation force (shear force), cyclically varying between 0 and 350 +/- 1 N. After 200,000 load cycles, the upper and lower glenoid component rim-displacements were measured by custom-made displacement sensors. Additionally, the shear-out strength has been measured to investigate the residual strength. The glenoid component structures with radii of curvature of 24, 25, and 29 mm showed maximum superior rim-displacements of 0.163 (SD = 0.01), 0.299 (SD = 0.0306), and 0.350 (SD = 0.0197) mm respectively, which is a significant difference (p < 0.05). The maximum shear-out strength of glenoid components with radii of curvature of 24, 25, and 29 mm was 2707 (SD = 452), 2648 (SD = 299), and 2631 (SD = 312) N respectively, which is not a significant difference (p < 0.05). However, the results indicate that a conform articulation shows smaller glenoid rim-displacements, which might be beneficial for long-term component fixation.

Arthroplasty↗

Translational stiffness of the replaced shoulder joint.

Results after a total shoulder arthroplasty in rheumatoid patients are poor, indicated by loosening of especially the glenoid component, bad joint functionality and the possibility of a joint dislocation. The failure mechanisms behind this are multiple, including patient, surgical and design factors. These results must be improved. At present, the optimal geometrical prosthesis component design, focused on joint conformity and constraint, still has to be investigated. Proper understanding of the effect of geometrical design parameters on the theoretical relationship between joint translations and joint forces may contribute to improved designs. The main objective of this study is to theoretically describe this relationship and to investigate the joint translational stiffness, which can be used to investigate the effect of design parameters on joint motion. Joint translational stiffness is the gradient of the subluxation force with respect to the humeral head displacement. For this static analysis a potential field is introduced, as the result of a joint compressive force (muscle forces) and a subluxation force (external forces). The positive and negative stiffness during articulation inside and subluxation outside the glenoid cavity, lead to stable and unstable equilibrium joint positions, respectively. A most lateral position of the humeral head centre coincides with a zero subluxation force; at this position the humerus is dislocated and a restoring force is needed to relocate the humeral head. Joint conformity and compression force influence the joint translational stiffness during articulation inside the glenoid cavity, whereas during articulating outside the glenoid cavity this is influenced by the joint compression force and humeral radius of curvature. The glenoid radius of curvature influences the contact point and, in combination with the glenoid superior-inferior chord length, it also influences the constraintness angle, which influences the maximum allowable subluxation load to prevent a joint dislocation. This constraintness angle together with the joint conformity also influences maximum joint translations before articulation outside the glenoid cavity. Furthermore, the sign of the joint translational stiffness determines the stability of shoulder motion, which is stable and unstable if this stiffness is positive and negative, respectively.

Computer Simulation↗