Effects of microstructure on the corrosion behavior of CoCr porous coatings on orthopedic implants.

Cobalt-chromium alloy porous coatings have become increasingly popular as a means of achieving a stable, longer lasting fixation on orthopedic implants. However, sintering heat treatments cause changes in the microstructure that result in changes in the corrosion behavior of the porous coatings. Experiments were conducted to examine the effects of microstructure on the corrosion of CoCr porous coatings. Four distinct microstructures were characterized. Light microscopy revealed microstructures A and B had relatively fewer carbides and a large-grain structure, microstructures C and D displayed a finer grain size with significant carbide formation, predominantly within grains and fusion zones. Accelerated anodic corrosion experiments were conducted to study the localized attack of each microstructure. Experiments were conducted using metallographically polished porous-coated disks for durations of 1, 4, 16, 24, and 72 h. The disks were examined with SEM and EDS to observe preferential attack and element depletion. Results showed a progressive dissolution of the matrix, with preferential attack of the grain boundaries and regions adjacent to the carbides due to sensitization. A precipitation layer was found to be Cr-rich and possibly composed of chromium hydroxide or a chromium orthophosphate. In addition, the solution became yellow in color with longer exposure times, possibly due to the presence of chromate ions, as indicated by an increased chromium level detected by AAS.

Alloys↗

Fretting corrosion accelerates crevice corrosion of modular hip tapers.

The use of multiple-component systems in orthopedic surgery gives the surgeon increased flexibility in choosing the optimal implant, but introduces the possibility of interfacial corrosion. Such corrosion could limit the longevity of prostheses due either to tissue reactions to corrosion products, or to device failure. The incidence and nature of corrosion of modular total hips was evaluated in a consecutive series of 79 retrieved implants from University Hospitals of Cleveland. Surfaces were examined with stereo- and scanning electron microscopy. Several laboratory studies were undertaken to examine mechanisms that might contribute to the initiation of corrosion. The first set of experiments investigated the effect of head neck extension; the second study looked at the effect of material combinations on fretting corrosion and crevice corrosion. Analysis of retrieved implants demonstrated that fretting corrosion played a major role in the initiation of interface corrosion, and that a correlation existed between corrosion and length of neck extensions. Laboratory studies showed that longer head neck extensions may be more susceptible to fretting corrosion because of an instability at the interface. Short-term mixed-metal corrosion studies demonstrated that the coupling of cobalt and titanium alloys did not render the interface more susceptible to corrosion. It is hypothesized that fretting corrosion contributes to the initiation of modular interface corrosion, and that the problem can be reduced by design changes that increase the stability of the interface.

Alloys↗

Surface characterization of titanium-based implant materials.

This study examined the effects of different treatments (polished, electropolished, and grit-blasted) on the surface morphology and chemistry of commercially pure titanium and titanium-6% aluminum-4% vanadium. The structure and composition of the surfaces were evaluated using scanning electron microscopy, atomic force microscopy, energy dispersive spectroscopy, Auger microprobe analysis, and x-ray photoelectron spectroscopy. Surface roughness values at large scales were nearly identical for grit-blasted and electropolished samples, while at smaller scales, electropolished and polished samples had nearly identical quantitative roughness values. The surface oxide compositions were found to be primarily titanium dioxide on both materials for all surface treatments. No vanadium was seen with either x-ray photoelectron spectroscopy or Auger microprobe analysis for the alloy, indicating a possible surface depletion. Calcium was present on the grit-blasted samples, and calcium and chlorine were detected on the electropolished samples.

Alloys↗