Comparative clinical and angiographic analysis of the initial efficacy and long-term follow-up of Wiktor stent implantation with conventional balloon angioplasty.

This study was retrospectively designed to examine if the Wiktor stent, a balloon-expandable tantalum coil stent, provides a more favorable procedural and long-term clinical and angiographic outcome than does conventional coronary balloon angioplasty (POBA). From April 1995 to April 1996, we implanted 56 Wiktor stents in 46 lesions (LAD: 23, RCA: 16, CX: 7) in 42 patients (average age 53 +/- 10 years). Coronary lesions from the stent group were matched with similar lesions of another 42 POBA patients whose characteristics were identical to the Wiktor group. Revascularization indications in the Wiktor and POBA groups, respectively, were recent myocardial infarction (RMI) (45%, 40%), unstable (31%, 39%) and stable (24%, 21%) angina pectoris. 7% of the stents and 17% of the POBA balloons were less than 3 mm in diameter (p > 0.05). Procedural success was significantly greater in the Wiktor group than in the POBA group (100% vs. 92%, p < 0.05). Neither major cardiac event (death, CABG, acute myocardial infarction) nor (sub)acute occlusion was encountered in the Wiktor group during the hospitalization period and 1 month follow-up. There was 1 urgent CABG and 4 subacute occlusions in the POBA group. Control angiography at 8 months was performed in patients of both groups, of whom some were symptomatic at long-term follow-up or completely event free for 8 months. Angiographic restenosis (> 50% diameter stenosis) occurred in 25% of the Wiktor patients and in 43% of those in the POBA group (p < 0.05). For an 18 month clinical follow-up, 91% of the patients in the Wiktor group were asymptomatic and without ischemia in radionuclide imaging (RI), whereas 79% of the POBA patients were angina-free and 74% were without ischemia in the RI study. In conclusion, Wiktor stent implantation, with no major cardiac event or subacute occlusion, provides a more favorable procedural and long-term clinical and angiographic outcome than does conventional POBA.

Adult↗

Semantics of insulin.

The lack of a stringent terminology and a well-defined vocabulary for insulin and related subjects has been a deterrent to solving many of the problems encountered when using insulin in pumps. The same word is sometimes used to describe a number of different phenomena or the same phenomenon is referred to by different words. Thus the word 'insulin', meaning the substance, the protein hormone, is commonly used as a synonym for an 'insulin formulation' for the treatment of diabetes. The 'insulin dimer' can be the covalent or the non-covalent dimer, two very different substances. 'Isoelectric precipitation' is often mistaken for 'fibrillation' and both are referred to as 'aggregation' or 'polymerization'. The word 'crystal' is being used as a synonym for 'particle', and determination of 'the content of insulin' by HPLC is sometimes called a 'bioassay'. The nature and consequences of these pitfalls are discussed, and advice is given on how to avoid them.

Insulin↗

Insulin pumps. A technical review.

The technique employed in open-loop insulin infusion pumps is reviewed. Most commonly used syringe as well as peristaltic pumps are exemplified. Their weights and prices are compared. Possibilities of development are discussed.

Insulin Infusion Systems↗