PubMed Health⌕ Search

Biomedical subjects

H Eickhoff

Publications and source records attributed to H Eickhoff.

At least 19 recordsLinked to original sources

Development of a technology for automation and miniaturization of protein crystallization.

The usage of standard 96 well microplates for the screening of crystallization conditions of recombinant proteins offers several advantages when compared to commonly used crystallization plate formats. The adoption of robotic technology for plate and glass slide preparation within a "hanging drop" vapour diffusion crystallization experiment enables to work with an increased throughput at reduced costs. In addition to commercial pipetting devices with a 96-channel aspirator/dispenser, solenoid ink-jet technology was applied to form 250 nl droplets with a diameter of approximately 1 mm. This allows miniaturization of crystallization screening set-ups with an estimated ten-fold cost reduction when compared to commonly used 24 well plates.

Concanavalin A↗

Large-gel two-dimensional electrophoresis-matrix assisted laser desorption/ionization-time of flight-mass spectrometry: an analytical challenge for studying complex protein mixtures.

The large-gel two-dimensional electrophoresis (2-DE) technique, developed by Klose and co-workers over the past 25 years, provides the resolving power necessary to separate crude proteome extracts of higher eukaryotes. Matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) provides the sample throughput necessary to identify thousands of different protein species in an adequate time period. Spot excision, in situ proteolysis, and extraction of the cleavage products from the gel matrix, peptide purification and concentration as well as the mass spectrometric sample preparation are the crucial steps that interface the two analytical techniques. Today, these routines and not the mass spectrometric instrumentation determine how many protein digests can be analyzed per day per instrument. The present paper focuses on this analytical interface and reports on an integrated protocol and technology developed in our laboratory. Automated identification of proteins in sequence databases by mass spectrometric peptide mapping requires a powerful search engine that makes full use of the information contained in the experimental data, and scores the search results accordingly. This challenge is heading a second part of the paper.

Animals↗

The novel transcription factor e(y)2 interacts with TAF(II)40 and potentiates transcription activation on chromatin templates.

Weak hypomorph mutations in the enhancer of yellow genes, e(y)1 and e(y)2, of Drosophila melanogaster were discovered during the search for genes involved in the organization of interaction between enhancers and promoters. Previously, the e(y)1 gene was cloned and found to encode TAF(II)40 protein. Here we cloned the e(y)2 gene and demonstrated that it encoded a new ubiquitous evolutionarily conserved transcription factor. The e(y)2 gene is located at 10C3 (36.67) region and is expressed at all stages of Drosophila development. It encodes a 101-amino-acid protein, e(y)2. Vertebrates, insects, protozoa, and plants have proteins which demonstrate a high degree of homology to e(y)2. The e(y)2 protein is localized exclusively to the nuclei and is associated with numerous sites along the entire length of the salivary gland polytene chromosomes. Both genetic and biochemical experiments demonstrate an interaction between e(y)2 and TAF(II)40, while immunoprecipitation studies demonstrate that the major complex, including both proteins, appears to be distinct from TFIID. Furthermore, we provide genetic evidence suggesting that the carboxy terminus of dTAF(II)40 is important for mediating this interaction. Finally, using an in vitro transcription system, we demonstrate that recombinant e(y)2 is able to enhance transactivation by GAL4-VP16 on chromatin but not on naked DNA templates, suggesting that this novel protein is involved in the regulation of transcription.

Amino Acid Sequence↗

New tools for oligonucleotide fingerprinting.

Oligonucleotide fingerprinting is an attractive, high-throughput complement to tag sequencing methods to determine the spectrum and abundance of genes in cDNA libraries. This method currently relies on the sequential hybridizations of short, radioactively labeled DNA oligonucleotides to clone arrays. Here, we describe a new environment that substantially improves this technology. Fluorescently labeled peptide nucleic acid (PNA) oligonucleotides are used as hybridization probes. Hybridization results are recorded with a large-field, high-resolution laser scanner developed for this purpose. Automated image analysis allows easy handling of large numbers of hybridization images. Signal interference effects, which limit the gridding density in the radioactive approach, are strongly reduced. The sensitivity of the fluorescence detection demonstrated permits the convenient use of nylon membranes. Hybridization data quality is improved, and its generation is substantially accelerated, simplified, and less expensive.

Autoanalysis↗

Prestructured MALDI-MS sample supports.

Prestructured MALDI-MS sample supports have been developed that simplify high-throughput analysis of biomolecules and improve the detection sensitivity. The mass spectrometric sample support is coated with a thin layer of hydrophobic Teflon that carries an array of 200-microm gold spots, which provide hydrophilic sample anchors. Each transferred sample droplet contacts one anchor, on top of which, after solvent evaporation, the sample is exclusively deposited due to the strongly water repellent nature of the Teflon surface. The initial matrix concentration is kept low, enabling sample up-concentration by more than 2 orders of magnitudes before crystallization commences. As a result, the detection sensitivity is improved as documented by mass spectra recorded from 100 amol of various peptides, 1 fmol of a DNA 20 mer, and 5 fmol of a 130 bp PCR product. Size and spacing of the hydrophilic anchors are optimized for MALDI-MS performance (sample spot size approximately = laser irradiation spot size), for short analysis times (predetermined sample coordinates), and for high throughput sample preparation (sample anchor array according to the 1536 microtiter plate format).

DNA↗

Normalization strategies for cDNA microarrays.

Multiple Arabidopsis thaliana clones from an experimental series of cDNA microarrays are evaluated in order to identify essential sources of noise in the spotting and hybridization process. Theoretical and experimental strategies for an improved quantitative evaluation of cDNA microarrays are proposed and tested on a series of differently diluted control clones. Several sources of noise are identified from the data. Systematic and stochastic fluctuations in the spotting process are reduced by control spots and statistical techniques. The reliability of slide to slide comparison is critically assessed within the statistical framework of pattern matching and classification.

Arabidopsis↗

Induction of putative tumor-suppressing genes in Rat-1 fibroblasts by oncogenic Raf-1 as evidenced by robot-assisted complex hybridization.

The growth factor receptor-dependent protein kinase Raf-1 is activated by GTP-bound Ras, thereby activating the mitogen-activated protein kinase pathway. To study the role of Raf in transformation we transduced Rat-1 cells with a tetracycline-regulatable retroviral vector encoding the constitutively active oncogenic C-terminal fragment of the human Raf-1 protein. Using subtractive hybridization of mRNAs from induced and noninduced cells and robot-assisted screening by complex hybridization, Raf-induced genes with various different characteristics of induction were investigated. Among the strongly induced genes were those involved in carcinogenesis such as metalloproteinases 3, 10 and 13, cathepsin L, ornithine decarboxylase, and putative tumor-suppressing genes such as monocyte chemoattracting protein 1, interferon-induced protein 10, a recently identified 2'-5' oligoadenylate synthetase-like protein, and plasminogen activator inhibitor type 2. Other components of the plasminogen activator system were not induced. Plasminogen activator inhibitor type 2 is a down-regulator of the proteolytic cascade consisting of various metalloproteinases, some of which are induced by a carboxy-terminal Raf mutant (RafCT). In conclusion, RafCT induces factors which act in a conflicting manner in respect of carcinogenesis, especially within the proteolytic system of the extracellular matrix.

Animals↗

Tissue gene expression analysis using arrayed normalized cDNA libraries.

We have used oligonucleotide-fingerprinting data on 60,000 cDNA clones from two different mouse embryonic stages to establish a normalized cDNA clone set. The normalized set of 5,376 clones represents different clusters and therefore, in almost all cases, different genes. The inserts of the cDNA clones were amplified by PCR and spotted on glass slides. The resulting arrays were hybridized with mRNA probes prepared from six different adult mouse tissues. Expression profiles were analyzed by hierarchical clustering techniques. We have chosen radioactive detection because it combines robustness with sensitivity and allows the comparison of multiple normalized experiments. Sensitive detection combined with highly effective clustering algorithms allowed the identification of tissue-specific expression profiles and the detection of genes specifically expressed in the tissues investigated. The obtained results are publicly available (http://www.rzpd.de) and can be used by other researchers as a digital expression reference.

Algorithms↗

Protein microarrays for gene expression and antibody screening.

Proteins translate genomic sequence information into function, enabling biological processes. As a complementary approach to gene expression profiling on cDNA microarrays, we have developed a technique for high-throughput gene expression and antibody screening on chip-size protein microarrays. Using a picking/spotting robot equipped with a new transfer stamp, protein solutions were gridded onto polyvinylidene difluoride filters at high density. Specific purified protein was detected on the filters with high sensitivity (250 amol or 10 pg of a test protein). On a microarray made from bacterial lysates of 92 human cDNA clones expressed in a microtiter plate, putative protein expressors could be reliably identified. The rate of false-positive clones, expressing proteins in incorrect reading frames, was low. Product specificity of selected clones was confirmed on identical microarrays using monoclonal antibodies. Cross-reactivities of some antibodies with unrelated proteins imply the use of protein microarrays for antibody specificity screening against whole libraries of proteins. Because this application would not be restricted to antigen-antibody systems, protein microarrays should provide a general resource for high-throughput screens of gene expression and receptor-ligand interactions.

Antibody Specificity↗

A fully automated multicapillary electrophoresis device for DNA analysis.

We describe the construction and performance of a fully automated multicapillary electrophoresis system for the analysis of fluorescently labeled biomolecules. A special detection system allows the simultaneous spectral analysis of all 96 capillaries. The main features are true parallel detection without any moving parts, high robustness, and full compatibility to existing protocols. The device can process up to 40 microtiter plates (96 and 384 well) without human interference, which means up to 15,000 samples before it has to be reloaded.

Automation↗

The GSI Cancer Therapy Project.

At the Heavy Ion Research Institute GSI in Darmstadt an experimental cancer treatment program with a five years duration has been developed. A new method for cancer treatment with ions is applied, using rasterscan method in addition to an active pulse to pulse variation of ion beam properties, including the energy, intensity and focusing. An overview of this Cancer Therapy Project is presented, that covers both accelerator aspects to provide the required beam variations within a short time and the installations at the treatment place for rasterscan control. In addition to a description of the technical design (control-hard- and software) experimental results will be shown, containing the achieved beam properties and measurements of rasterscan performance.

Academies and Institutes↗

SH3GL3 associates with the Huntingtin exon 1 protein and promotes the formation of polygln-containing protein aggregates.

The mechanism by which aggregated polygins cause the selective neurodegeneration in Huntington's disease (HD) is unknown. Here, we show that the SH3GL3 protein, which is preferentially expressed in brain and testis, selectively interacts with the HD exon 1 protein (HDex1p) containing a glutamine repeat in the pathological range and promotes the formation of insoluble polyglutamine-containing aggregates in vivo. The C-terminal SH3 domain in SH3GL3 and the proline-rich region in HDex1p are essential for the interaction. Coimmunoprecipitations and immunofluorescence studies revealed that SH3GL3 and HDex1p colocalize in transfected COS cells. Additionally, an anti-SH3GL3 antibody was also able to coimmunoprecipitate the full-length huntingtin from an HD human brain extract. The characteristics of the interaction between SH3GL3 and huntingtin and the colocalization of the two proteins suggest that SH3GL3 could be involved in the selective neuronal cell death in HD.

Adaptor Proteins, Signal Transducing↗

[Changes in lung function after cholecystectomy--open versus laparoscopic cholecystectomy].

Impairment of respiratory function after open cholecystectomy may cause atelectasis and hypoxemia. Clinical experience shows evidence for easier recovery after laparoscopic operation. Postoperative respiratory function using spirometric tests was assessed in 50 patients with simple symptomatic cholecystolithiasis submitted either to open or laparoscopic cholecystectomy and revealed less impairment of respiratory function in the laparoscopic group.

Cholecystectomy↗

Fractals for multicyclic synthesis conditions of biopolymers. Examples of oligonucleotide synthesis measured by high-performance capillary electrophoresis and ion-exchange high-performance liquid chromatography.

We have developed models of patterns for nucleotide chain growth. These patterns are measurable by high-performance capillary electrophoresis and ion-exchange high-performance liquid chromatography in crude products of solid-phase synthesized 30mer and 65mer oligodeoxyribonucleotide target sequences N. We introduce mathematical methods for finding characteristic values d(o) and p(o) for constant chemical modes of growth as well as d and p for non-constant chemical modes of growth (d = probability of propagation, p = probability of termination). These methods are employed by presenting the accompanying computer software developed by us in C code, Mathematica R languages, and Fortran. Characteristic values of the parameters d, p, and the target nucleotide length N describe the complete composition of the crude product. From this we have developed the relation 2 - [N/(N - 1)]/Da, measurable(N,d) as a universal quantitative measure for multicyclic synthesis conditions (D, fractal dimension and similarity exponent, respectively). We use this mathematical treatment to compare the efficiency of oligodeoxyribonucleotide syntheses of different target length N on polymer support materials. Further, we analyze selected syntheses of short and long oligodeoxyribonucleotides as well as single-stranded DNA sequences by well-known empirical autocorrelation, fast Fourier transformation, and embedding dimension techniques.

Base Sequence↗

Sequence verification by hybridisation with fluorescent octanucleotides as a first step to a fluorescent sequencing by hybridisation protocol.

Three sets of partly overlapping octanucleotides are 5' labelled with derivates of the fluorescence dyes fluorescein-, coumarine- and rhodamine, respectively. Hybridisation conditions are determined, under which all octanucleotides hybridise correctly against complementary target sequences bound on nylon membranes. Target sequences are three synthetic 48-mer oligonucleotides and herring sperm DNA, a positive control containing almost all possible octanucleotides. None of the octanucleotides hybridised to incorrect target sequences. Analysing these results, a given sequence could be unambiguously verified. A feature critical for the accuracy of the hybridisation is the temperature during the last washing step. This temperature can be estimated using the equation T = 19 - 0.4(G + C) + 0.15(G + C)2. Using octanucleotides labelled with three different colors, three hybridisations can be performed simultaneously.

Animals↗