PubMed Health⌕ Search

Biomedical subjects

H Erdman

Publications and source records attributed to H Erdman.

3 recordsLinked to original sources

Evaluation of the Digene Hybrid Capture II Assay with the Rapid Capture System for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

Screening for chlamydial and gonococcal infection has been strongly recommended for all sexually active women under the age of 26. Advances in the ability to detect infection by nucleic acid detection techniques have improved access to screening methods in routine clinical practices. To meet the increasing demand for testing, a high-throughput system is desirable. We evaluated the performance of the Hybrid Capture 2 CT/GC (HC2) assay with the Digene Rapid Capture System (HC2-RCS). The results of HC2-RCS for endocervical samples from 330 women were compared to those of culture and the COBAS Amplicor PCR. For detection of chlamydial infection, HC2-RCS had a sensitivity and a specificity similar to those of PCR (P > 0.5) and an improved sensitivity compared to that of culture (P = 0.007). For identification of gonococcal infections, all assays performed similarly (P > 0.5). The performance of HC2-RCS was also compared to that of the manual HC2 format (HC2-M) with these samples and with 911 endocervical samples collected previously. The performance of HC2-RCS was equivalent to that of HC2-M; the overall concordance rates for the detection of chlamydia and gonorrhea were 99.7% (kappa = 0.97) and 99.8% (kappa = 0.97), respectively. When the HC2 assay was performed with a semiautomated system application designed for high throughput, it demonstrated high sensitivity and a high specificity for detection of both Chlamydia trachomatis and Neisseria gonorrhoeae.

Chlamydia Infections↗

Evaluation of a computerized contraceptive decision aid for adolescent patients.

Recent efforts to involve patients more actively in therapeutic decisions have suggested the relevance of computer-based interventions at clinic visits. This paper presents a longitudinal, experimental study evaluating a computer-based contraceptive decision aid in Chicago and Madison family planning clinic visits. Patient interviews at three time points evaluated patient acceptance by and program impact on 949 young women. Both Chicago and Madison patients reported high acceptance. The program resulted in improved short-term knowledge and confidence in oral contraceptive (OC) efficacy for Chicago and Madison patients. In addition, compared to their control group, Madison experimental group patients had higher OC knowledge 1 year after the initial visit and a trend for fewer pregnancies (P < 0.074). Compared to their control group, a higher percent of the Chicago experimental group patients adopted OC's after stating their intention to do so at the initial visit. Exposure to the computer program had no observable impact on the number of months on the oral contraceptive for Chicago or Madison patients. Overall findings suggest the usefulness of informatics tools as a supplement to patient-provider interactions.

Adolescent↗