Adaptive ventilator FiO2 advisor: use of non-invasive estimations of shunt.

A non-invasive and simple method of parameter estimation has been developed for the model-based decision support of the artificial ventilation in intensive care units. The parameter concerned was the respiratory shunt. Originally, the shunt had to be estimated using a numerical algorithm, which was slow and unreliable. The estimation process also required the knowledge of other parameters, whose values could only be obtained using invasive monitoring equipment. In this paper, the respiratory index is used for the shunt estimation. A linear regression model and a non-linear adaptive neuro-fuzzy inference system (ANFIS) model were used to describe the relationship between the respiratory index and the shunt. The shunts estimated using these models were then used to calculate the fractional inspired oxygen needed to attain the target arterial oxygen level of the model patient. The advisor also utilises population median values of the cardiac index and oxygen consumption index. This alleviates the need for invasive monitoring. In a simulation study, the mean squared error of the control using the ANFIS model was 0.75 kPa2 compared to 2.06 kPa2 using the linear regression model. Therefore, the performance of the FiO2 advisor was better when the shunt was estimated using the non-linear ANFIS model.

Algorithms↗

Rule-base derivation for intensive care ventilator control using ANFIS.

In recent years, much research has been done on the use of fuzzy systems in medicine. The fuzzy rule-bases have usually been derived after extensive discussion with the clinical experts. This takes a lot of time from the clinical experts and the knowledge engineers. This paper presents the use of the adaptive neuro-fuzzy inference system (ANFIS) in rule-base derivation for ventilator control. The change of the inspired fraction of oxygen (FiO(2)) advised by eight clinical experts responding to 71 clinical scenarios was recorded. ANFIS and a multilayer perceptron (MLP) were then used to model the relationship between the inputs (the arterial oxygen tension (PaO(2)), FiO(2) and the positive end-expiratory pressure (PEEP) level) and the change in FiO(2) suggested. Compared to a previous fuzzy advisor (FAVeM), both the ANFIS and the MLP were found to correlate with the clinicians' decision better (correlation coefficient of 0.694 and 0.701, respectively compared to 0.630). A formerly developed model-based radial basis network advisor (RBN-MB) was used for comparison. Closed-loop simulations showed that the ANFIS, MLP and the RBN-MB's performance were comparable to the clinicians' performance (correlation coefficients of 0.852, 0.962 and 0.787, respectively). The FAVeM's performance differed from the clinicians' performance (correlation coefficient of 0.332) but the resulting PaO(2) was still within safety limits.

Computer Simulation↗