Amperometric biosensor for determining human salivary phosphate.

An amperometric biosensor was constructed for analysis of human salivary phosphate without sample pretreatment. The biosensor was constructed by immobilizing pyruvate oxidase (PyOD) on a screen-printed electrode. The presence of phosphate in the sample causes the enzymatic generation of hydrogen peroxide (H(2)O(2)), which was monitored by a potentiostat and was in proportion to the concentration of human salivary phosphate. The sensor shows response within 2s after the addition of standard solution or sample and has a short recovery time (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 to 625 microM phosphate with a detection limit of 3.6 microM. A total of 50 salivary samples were collected for the determination of phosphate. A good level of agreement (R(2)=0.9646) was found between a commercial phosphate testing kit and the phosphate sensor. This sensor maintained a high working stability (>85%) after 12h operation and required only a simple operation procedure. The amperometric biosensor using PyOD is a simple and accurate tool for rapid determinations of human salivary phosphate, and it explores the application of biosensors in oral and dental research and diagnosis.

Biosensing Techniques↗

A screen-printed biosensor using pyruvate oxidase for rapid determination of phosphate in synthetic wastewater.

A screen-printed phosphate biosensor based on immobilized pyruvate oxidase (PyOD, E.C. 1.2.3.3) has been developed for monitoring phosphate concentrations in a sequencing batch reactor (SBR) system. The enzyme was immobilized by a nafion matrix and covered a poly(carbamoyl) sulfonate (PCS) hydrogel on a screen-printed electrode. PyOD consumes phosphate in the presence of pyruvate and oxygen and generates hydrogen peroxide (H2O2), carbon dioxide and acetylphosphate. The electroactive H2O2, monitored at +420 mV vs Ag/AgCl, is generated in proportion to the concentration of phosphate. The sensor has a fast response time (2 s) and a short recovery period (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 microM to 625 microM phosphate with a detection limit of 3.6 microM. There was good agreement (R2=0.9848) between the commercial phosphate testing kit and the phosphate sensor in measurements of synthetic wastewater in a SBR system. This sensor maintained a high working stability (>85%) after 12 h of operation and involved a simple operation procedure. It therefore serves as a useful tool for rapid and accurate phosphate measurements in the SBR system and probably for process control.

Bioreactors↗