[Intracranial hemodynamics in phenobarbital administration].

The effect of phenobarbital application on cerebral hemodynamics was studied in premature lambs. Near infrared spectroscopy was used for noninvasive monitoring of oxyhemoglobin, deoxyhemoglobin, total hemoglobin and cytochrom a/a3. Total intracranial blood volume decreased shortly after giving the drug and remained then on a stable lowered niveau. This could be explained with shifting of blood in different brain regions or with a decreased total intracranial blood volume.

Animals↗

[Sialidosis and galactosialidosis as the cause of non-immunologic hydrops fetalis].

Two cases of non-immunological hydrops fetalis (NIHF) presenting with massive ascites are reported; in both patients an oligosaccharid-pattern in the urine typical for sialidosis resp. galactosialidosis was found. The cerebral sonography of both patients showed streaky echo enhancement in the region of the thalamostriatal vessels, which was interpreted as calcification of the vessels. The courses of the patients were characterised by recurrent infections, hepatosplenomegaly and myoclonus. Relevant literature reports on a large variability in the clinical appearance of oligosaccharidoses. The diagnosis of sialidosis is confirmed in cultured fibroblasts by the deficiency of alpha-N-acetylneuraminidase and, in case of galactosialidosis by the additional lack of beta-galactosidase. The precise diagnosis in NIHF is of increasing interest for prenatal diagnostic as well as for neonatological management.

Brain↗

Blood glucose determinations in newborns: four instruments compared.

Four portable analyzers, HemoCue B-Glucose (I), Accu-Check III (II), One-touch II (III), and Glucometer Elite (IV), with different measuring principles were tested for their suitability for measuring blood glucose in neonates. Precision of all instruments is satisfactory. In the analysis of capillary blood from newborns, two instruments show an excellent accuracy; however, the scatter of the results for instrument (II) is about 1.6 times greater than for instrument (I). The inaccuracy of instruments (III) and (IV) is not acceptable from a clinical point of view. All devices show an influence of hematocrit, the magnitude of which varies between 5% (I) and 12% (III) for every 10% change of hematocrit. Instruments II and IV show that temperature has a marked influence on the readings; the same is true for oxygen in instrument IV. In conclusion, only instrument (I) has met the requirements of accurate and precise blood glucose determinations in neonates.

Blood Chemical Analysis↗