PubMed Health⌕ Search

Biomedical subjects

H Fessler

Publications and source records attributed to H Fessler.

6 recordsLinked to original sources

Elliptic flow in Au+Au collisions at square root(S)NN = 130 GeV.

Elliptic flow from nuclear collisions is a hadronic observable sensitive to the early stages of system evolution. We report first results on elliptic flow of charged particles at midrapidity in Au+Au collisions at square root(S)NN = 130 GeV using the STAR Time Projection Chamber at the Relativistic Heavy Ion Collider. The elliptic flow signal, v2, averaged over transverse momentum, reaches values of about 6% for relatively peripheral collisions and decreases for the more central collisions. This can be interpreted as the observation of a higher degree of thermalization than at lower collision energies. Pseudorapidity and transverse momentum dependence of elliptic flow are also presented.

Journal Article↗

Immune response to autologous transfusion in healthy volunteers: WB versus packed RBCs and FFP.

BACKGROUND: Storage of blood as packed RBCs and FFP is standard practice in allogeneic transfusion. Separation into components has been proposed for autologous transfusion, as well, but beneficial effects have not yet been shown. STUDY DESIGN AND METHODS: Twenty-four healthy male volunteers were randomly assigned to receive 1 unit of either autologous RBCs and FFP (RCP group) or WB (WB group) after 49 or 35 days of storage, respectively. The immune response was analyzed by ELISA for IL-6, C3a, terminal complement complex SC5b-9, TNF-alpha, and neopterin. Differential WBC counts and the phagocytosis of neutrophils and monocytes were measured by flow cytometry. RESULTS: Cell counts of monocytes (0.85 x 10(3) ng/microL) [corrected] and neutrophils (6.9 x 10(3) ng/microL) [corrected] increased 30 minutes after WB transfusion and then returned to close to the baseline values seen in the RCP group (0.47 and 2.9 x 10(3) ng/microL [corrected], respectively) throughout the monitored period (p<0.05). C3a (169 vs. 116 ng/microL) [corrected] and IL-6 (29 vs. 6 pg/mL) reached higher plasma concentrations in the WB group (n = 11) than in the RCP group (n = 10). Phagocytosis of opsonized Escherichia coli was increased in neutrophils and monocytes and lasted up to 7 days after the transfusion of whole blood. CONCLUSION: Autologous WB induces a modest immunomodulation, but this effect is not observed upon transfusion of autologous blood components.

Adolescent↗

Air trapping in the lungs during cardiopulmonary resuscitation in dogs. A mechanism for generating changes in intrathoracic pressure.

To test the hypothesis that during cardiopulmonary resuscitation, chest compression with an unobstructed trachea raises and maintains intrathoracic pressure by collapsing airways and trapping air in the lung, we studied 11 dogs (20-32 kg). An inflatable vest compressed the thorax after induction of ventricular fibrillation. First, tracheal airflow was measured by a pneumotachometer during vest inflation and deflation in nine of the dogs. As expected, during the initial phase of vest inflation of cycles after ventilation, air moved out of the lungs, but then airflow stopped. After vest deflation, however, more air moved out of the lungs in eight of the nine dogs; this occurrence indicated that a portion of the inspired tidal volume was trapped during vest inflation. During cycles without prior ventilation, the amount of air expired by chest compression decreased, paradoxically, at higher peak vest pressure (p less than 0.002); this occurrence indicated that air was trapped at the higher vest pressures. The change in right atrial pressure was higher on cycles after ventilation than on cycles without prior ventilation (79 +/- 12 vs. 67 +/- 12 mm Hg [mean +/- SEM], p less than 0.005), and lung volume was higher on cycles after ventilation (p less than 0.001). Next, a 5-Fr micromanometer was advanced down the airway in eight of the dogs. With the tip of the micromanometer 5-8 cm distal to the carina, a zone of high pressure was noted in seven dogs; this high pressure suggested a zone of airway collapse distal to the carina.(ABSTRACT TRUNCATED AT 250 WORDS)

Air↗

Friction in femoral prosthesis and photoelastic model cone taper joints.

Static axial push-on and lift-off, and push-on and twist-off experiments were designed and performed to measure the effective, room-temperature coefficient of friction mu for different design femoral prosthesis cone taper joints comprising a universal head on a stem spigot. Alumina and metal heads were tested on metal spigots using either distilled water, Ringer's solution, blood or no lubricant. Complementary push-on and lift-off friction tests of Araldite model joints for subsequent frozen-stress, photoelastic stress analysis were performed at 130 degrees C. It was found that lubricant caused little decrease in the values of the coefficient of friction in prosthesis tapers. The values measured were typically mu = 0.2 for an alumina head on a Co-Cr-Mo or Ti-6Al-4V spigot, mu = 0.15 for a Co-Cr-Mo head on a Co-Cr-Mo or Ti-6Al-4V spigot and mu = 0.13 for a stainless steel head on a stainless steel spigot. For Araldite photoelastic models of an alumina head on a Vitallium spigot, as-cast taper surfaces lubricated with silicone grease gave consistent friction of typically mu = 0.14. The axial displacement of model heads on their spigots were compared with predicted values and previously measured values for prosthesis heads.

Epoxy Resins↗

A study of stresses in alumina universal heads of femoral prostheses.

Three-dimensional, frozen-stress photoelasticity was used to study the best shape for a proposed alumina universal head loaded on to a Vitallium cone taper spigot with a 30 degrees inclined force, as in vivo. Typical cone taper friction values were reproduced in the photoelastic models. The location of the highest tensile stresses in the Mark I shape with a flat crown was found to be on the inner surface of the crown. Changing to a torispherical surface in the Mark II shape reduced this magnitude. However, the Mark III shape with a hemispherical inner crown surface gave even lower stress there, equal to the maximum value of the hoop stress at the taper, which was measured to be fairly uniform both around and along the taper except at the ends where contact pressure concentrations were found to occur and it became reduced. Lamé axisymmetric cylinder stress predictions were found to be useful approximations to measured values and were generally overestimates of the tensile hoop stress at the head taper surface.

Aluminum↗