Chest radiographs boast superior anatomic detail.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to H G Chotas.
Explore the source record for details and available documents.
Photostimulable phosphor imaging is an exciting new technology that has several advantages over film/screen radiography, the most important of which is the linearity of the photostimulable phosphor system over a wide exposure latitude. The photostimulable phosphor image is digital, and as such, provides options of how the image is viewed by radiologists. This report discusses the various image-processing parameters available for a photostimulable phosphor system and describes a rational approach for selecting these parameters in portable chest radiography. As photostimulable phosphor imaging becomes more widely implemented, an understanding of the processing parameters will facilitate the production of images that take full advantage of the benefits of these systems.
Explore the source record for details and available documents.
We have evaluated a photostimulable phosphor x-ray imaging system [Philips Computed Radiography (PCR) system] for use in quantification of x-ray exposure in diagnostic radiography. An exponential function was fitted to data yielding quantitative x-ray exposure values as a function of digital pixel values. We investigated several factors that affect the accuracy of exposure measurement using the PCR including repeatability, background noise as a function of time delay between plate erasure and use, sensitivity variation between different plates, nonuniformity of sensitivity within a plate, decay of the latent image between time of exposure and readout (observed as a change in sensitivity), and the accuracy with which the (exponential) calibration function yields exposure values as a function of digital pixel values. The calibration was performed over the exposure range from 5.1 X 10(-9) to 2.0 X 10(-5) C/kg (0.02-75 mR). The accuracy of exposure measurements made with a single imaging plate is between 1.6% and 4.2%. If measurements from several plates are involved, the uncertainty in the final measurement will be between 5% and 5.9%.
X-ray scatter fractions measured with two detectors are compared: a photostimulable phosphor system (PSP) and a conventional film-screen technique. For both detection methods, a beam-stop technique was used to estimate the scatter fraction in polystyrene phantoms. These scatter fraction measurements are compared to previously reported film-based measurements. Scatter fractions obtained with the PSP were in good agreement both with measurements using film as well as with most previously reported measurements. For the PSP measurements, repeatability was better than 1%. It was found that the PSP provides a precise x-ray detector for quantitative scatter measurement in digital radiography.
The authors describe a method for directly digitizing optical images with a photostimulable phosphor (PSP) system. A PSP plate is initially charged with an exposure to a uniform x-ray field, and is then exposed to an optical image which discharges the plate in relation to the amount of incident light. Two applications were investigated: a contact-print technique for digitizing film radiographs, and a projection technique for digitizing transparent objects such as histology slides. Spatial uniformity was found to be adequate, and linearity of optical density response was excellent from 0.0-2.9 o.d. after look-up table correction. Spatial frequency response was degraded with the optical technique relative to the x-ray imaging properties of the plates, but was restorable by Fourier filtering. Image noise following spatial enhancement was satisfactory at intermediate to high optical densities using a high-resolution PSP plate, but was somewhat degraded at low densities.