PubMed Health⌕ Search

Biomedical subjects

H G Craighead

Publications and source records attributed to H G Craighead.

At least 19 recordsLinked to original sources

Nanofluidic structures for single biomolecule fluorescent detection.

Fluid-filled nanofabricated cavities can be used to increase the spatial resolution of single molecule confocal microscopy based techniques by creating smaller and more uniformly illuminated probe volumes. Such structures may also be used to temporarily stretch single macromolecules, permitting the resolution of molecular details that would otherwise be beyond the capabilities of a diffraction limited system.

DNA↗

Conformational analysis of single DNA molecules undergoing entropically induced motion in nanochannels.

We have used the interface between a nanochannel and a microchannel as a tool for applying controlled forces on a DNA molecule. A molecule, with a radius of gyration larger than the nanochannel width, that straddles such an interface is subject to an essentially constant entropic force, which can be balanced against other forces such as the electrophoretic force from an applied electric field. By controlling the applied field we can position the molecule as desired and observe the conformation of the molecule as it stretches, relaxes, and recoils from the nanochannel. We quantify and present models for the molecular motion in response to the entropic, electrophoretic, and frictional forces acting on it. By determining the magnitude of the drag coefficients for DNA molecules in the nanostructure, we are able to estimate the confinement-induced recoil force. Finally, we demonstrate that we can use a controlled applied field and the entropic interfacial forces to unfold molecules, which can then be manipulated and positioned in their simple extended morphology.

DNA↗

Zero mode waveguides for single-molecule spectroscopy on lipid membranes.

Zero mode waveguides (ZMWs), subwavelength optical nanostructures with dimensions ranging from 50 to 200 nm, have been used to study systems involving ligand-receptor interactions. We show that under proper conditions, lipid membranes will invaginate into the nanostructures, which confine optical excitation to subattoliter volumes. Fluorescence correlation spectroscopy (FCS) was used to characterize the diffusion of fluorescently tagged lipids in liquid-disordered phase 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) and gel phase 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC) membranes incubated on the nanostructured surface. In contrast to the POPC, DSPC membranes did not appear to enter the structures, suggesting that invagination is dependent on membrane rigidity. Although correlation curves obtained from POPC membranes conformed to previously derived models for diffusion in the evanescent field within the nanostructure, the diffusion constants obtained were systematically lower than expected. The validity of the one-dimensional diffusion model for membrane diffusion is discussed and it is concluded that the erroneous diffusion constants are a result of nontrivial membrane conformation within the ZMWs. Additionally, FCS was used to characterize the fraction of fluorescently labeled tetanus toxin C fragment bound to a ganglioside-populated POPC membrane within the ZMWs. This allowed the determination of the toxin's equilibrium binding constant at a concentration of 500 nM; higher than possible with diffraction-limited FCS. To our knowledge, the results presented here are the first reported for supported lipid bilayers in nanostructured devices. Furthermore, they open the possibility of studying membrane imbedded receptors and proteins at physiological concentrations with single-molecule resolution.

Gangliosides↗

Optically driven resonance of nanoscale flexural oscillators in liquid.

We demonstrate the operation of radio frequency nanoscale flexural resonators in air and liquid. Doubly clamped string, as well as singly clamped cantilever resonators, with nanoscale cross-sectional dimensions and resonant frequencies as high as 145 MHz are driven in air as well as liquid with an amplitude modulated laser. We show that this laser drive technique can impart sufficient energy to a nanoscale resonator to overcome the strong viscous damping present in these media, resulting in a mechanical resonance that can be measured by optical interference techniques. Resonance in air, isopropyl alcohol, acetone, water, and phosphate-buffered saline is demonstrated for devices having cross-sectional dimensions close to 100 nm. For operation in air, quality factors as high as 400 at 145 MHz are demonstrated. In liquid, quality factors ranging from 3 to 10 and frequencies ranging from 20 to 100 MHz are observed. These devices, and an all-optical actuation and detection system, may provide insight into the physics of the interaction of nanoscale mechanical structures with their environments, greatly extending the viscosity range over which such small flexural resonant devices can be operated.

Colloids↗

Individually resolved DNA molecules stretched and embedded in electrospun polymer nanofibers.

We have used the flow characteristics of an electrospinning jet to elongate and fix DNA molecules. We embedded and observed fluorescently labeled lambda bacteriophage DNA molecules in polyethylene oxide nanofibers. The embedded DNA molecules were imaged using fluorescence microscopy and found to be stretched to lengths approaching the full dyed contour length.

Bacteriophage lambda↗

Compression and free expansion of single DNA molecules in nanochannels.

We investigated compression and ensuing expansion of long DNA molecules confined in nanochannels. Transverse confinement of DNA molecules in the nanofluidic channels leads to elongation of their unconstrained equilibrium configuration. The extended molecules were compressed by electrophoretically driving them into porelike constrictions inside the nanochannels. When the electric field was turned off, the DNA strands expanded. This expansion, the dynamics of which has not previously been observable in artificial systems, is explained by a model that is a variation of de Gennes's polymer model.

Compressive Strength↗

A polymeric microchip with integrated tips and in situ polymerized monolith for electrospray mass spectrometry.

We describe the integration of a cyclo-olefin polymer based microchip with a sheathless capillary tip for electrospray ionization-mass spectrometry (ESI-MS). The microchip was fabricated by hot embossing and thermal bonding. Its design includes a side channel for adjusting the composition of the electrospray solution so that analytes in 100% water can be analyzed. The fused silica capillaries, used for sample introduction, and the electrospray tips for MS coupling were directly inserted into the microchannel before thermal bonding of the device. A microfabricated on-chip gold microelectrode was used to apply the electrospray voltage. Annealing the device after thermal bonding increased the pressure resistance of the microchip. The cross section of the microchannel was imaged by scanning electron microscopy to estimate the effects of the annealing step. The relationship between the applied electrospray voltages and MS signal was measured at different flow rates by coupling the device to an ion trap mass spectrometer. The performance of the microchip was evaluated by MS analysis of imipramine in ammonium acetate buffer solution by direct infusion. An alkylacrylate based monolith polymer bed for on-chip sample pretreatment and separation was polymerized in the microchannel and tested for ESI-MS applications.

Journal Article↗

Enumeration of DNA molecules bound to a nanomechanical oscillator.

Resonant nanoelectromechanical systems (NEMS) are being actively investigated as sensitive mass detectors for applications such as chemical and biological sensing. We demonstrate that highly uniform arrays of nanomechanical resonators can be used to detect the binding of individual DNA molecules through resonant frequency shifts resulting from the added mass of bound analyte. Localized binding sites created with gold nanodots create a calibrated response with sufficient sensitivity and accuracy to count small numbers of bound molecules. The amount of nonspecifically bound material from solution, a fundamental issue in any ultra-sensitive assay, was measured to be less than the mass of one DNA molecule, allowing us to detect a single 1587 bp DNA molecule.

Biosensing Techniques↗

lambda-Repressor oligomerization kinetics at high concentrations using fluorescence correlation spectroscopy in zero-mode waveguides.

Fluorescence correlation spectroscopy (FCS) has demonstrated its utility for measuring transport properties and kinetics at low fluorophore concentrations. In this article, we demonstrate that simple optical nanostructures, known as zero-mode waveguides, can be used to significantly reduce the FCS observation volume. This, in turn, allows FCS to be applied to solutions with significantly higher fluorophore concentrations. We derive an empirical FCS model accounting for one-dimensional diffusion in a finite tube with a simple exponential observation profile. This technique is used to measure the oligomerization of the bacteriophage lambda repressor protein at micromolar concentrations. The results agree with previous studies utilizing conventional techniques. Additionally, we demonstrate that the zero-mode waveguides can be used to assay biological activity by measuring changes in diffusion constant as a result of ligand binding.

Algorithms↗

Topographically modified surfaces affect orientation and growth of hippocampal neurons.

Extracellular matrix molecules provide biochemical and topographical cues that influence cell growth in vivo and in vitro. Effects of topographical cues on hippocampal neuron growth were examined after 14 days in vitro. Neurons from hippocampi of rat embryos were grown on poly-L-lysine-coated silicon surfaces containing fields of pillars with varying geometries. Photolithography was used to fabricate 1 microm high pillar arrays with different widths and spacings. Beta(III)-tubulin and MAP-2 immunocytochemistry and scanning electron microscopy were used to describe neuronal processes. Automated two-dimensional tracing software quantified process orientation and length. Process growth on smooth surfaces was random, while growth on pillared surfaces exhibited the most faithful alignment to pillar geometries with smallest gap sizes. Neurite lengths were significantly longer on pillars with the smallest inter-pillar spacings (gaps) and 2 microm pillar widths. These data indicate that physical cues affect neuron growth, suggesting that extracellular matrix topography may contribute to cell growth and differentiation. These results demonstrate new strategies for directing and promoting neuronal growth that will facilitate studies of synapse formation and function and provide methods to establish defined neural networks.

Animals↗

Quantitative mass spectrometric determination of methylphenidate concentration in urine using an electrospray ionization source integrated with a polymer microchip.

We have demonstrated the use of a simple microfabricated electrospray ionization source for coupling microfluidic chips to mass spectrometry (MS). A polymer-based microchip, coupled to a triple quadrupole mass spectrometer, has been employed for direct infusion quantitative bioanalysis of methylphenidate (Ritalin) extracted from human urine samples. The approach used a microfabricated polymer electrospray emitter to couple a microfluidic channel to a stable electrospray ionization source. The microchip was fabricated from cycloolefin plastic plate by hot embossing and thermal bonding. This microfluidic chip contained two independent microfluidic channels, integrated with two corresponding electrospray emitters and an internal gold electrode. Liquid-liquid extraction was used to prepare urine samples, spiked with methylphenidate. A trideuterated analogue of methylphenidate (methylphenidate-d(3)) was used as the internal standard for the analysis. The system showed good electrospray stability and reproducibility with different spray tips. Four different electrospray tips were used to analyze the same sample, and the results showed very small variation with a relative standard deviation of 1.4%. A standard curve prepared for methylphenidate in urine (R(2) = 0.999) was linear over the range of 0.4-800 ng/mL. The precision of the quality control samples for three different concentrations ranged from 19.1% at 20 ng/mL, 3.2% at 200 ng/mL, to 3.5% at 667 ng/mL while the accuracy was 96.3% at 20 ng/mL, 101.2% at 200 ng/mL, and 101.6% at 667 ng/mL. No system carryover was detected even when the same device was used for sequential analysis. These results suggest the potential of this microdevice for MS-based quantitative analysis in drug discovery and development.

Electrophoresis, Microchip↗

Brain responses to micro-machined silicon devices.

Micro-machined neural prosthetic devices can be designed and fabricated to permit recording and stimulation of specific sites in the nervous system. Unfortunately, the long-term use of these devices is compromised by cellular encapsulation. The goals of this study were to determine if device size, surface characteristics, or insertion method affected this response. Devices with two general designs were used. One group had chisel-shaped tips, sharp angular corners, and surface irregularities on the micrometer size scale. The second group had rounded corners, and smooth surfaces. Devices of the first group were inserted using a microprocessor-controlled inserter. Devices of the second group were inserted by hand. Comparisons were made of responses to the larger devices in the first group with devices from the second group. Responses were assessed 1 day and 1, 2, 4, 6, and 12 weeks after insertions. Tissues were immunochemically labeled for glial fibrillary acidic protein (GFAP) or vimentin to identify astrocytes, or for ED1 to identify microglia. For the second comparison devices from the first group with different cross-sectional areas were analyzed. Similar reactive responses were observed following insertion of all devices; however, the volume of tissue involved at early times, <1 week, was proportional to the cross-sectional area of the devices. Responses observed after 4 weeks were similar for all devices. Thus, the continued presence of devices promotes formation of a sheath composed partly of reactive astrocytes and microglia. Both GFAP-positive and -negative cells were adherent to all devices. These data indicate that device insertion promotes two responses-an early response that is proportional to device size and a sustained response that is independent of device size, geometry, and surface roughness. The early response may be associated with the amount of damage generated during insertion. The sustained response is more likely due to tissue-device interactions.

Animals↗

Zero-mode waveguides for single-molecule analysis at high concentrations.

Optical approaches for observing the dynamics of single molecules have required pico- to nanomolar concentrations of fluorophore in order to isolate individual molecules. However, many biologically relevant processes occur at micromolar ligand concentrations, necessitating a reduction in the conventional observation volume by three orders of magnitude. We show that arrays of zero-mode waveguides consisting of subwavelength holes in a metal film provide a simple and highly parallel means for studying single-molecule dynamics at micromolar concentrations with microsecond temporal resolution. We present observations of DNA polymerase activity as an example of the effectiveness of zero-mode waveguides for performing single-molecule experiments at high concentrations.

Biochemistry↗

Observation of locked intrinsic localized vibrational modes in a micromechanical oscillator array.

The nonlinear vibrational properties of a periodic micromechanical oscillator array have been measured. For sufficiently large amplitude of the driver, the optic mode of the di-element cantilever array becomes unstable and breaks up into excitations ranging over only a few cells. A driver-induced locking effect is observed to eternalize some of these intrinsic localized modes so that their amplitudes become fixed and the modes become spatially pinned.

Journal Article↗

Creating biological membranes on the micron scale: forming patterned lipid bilayers using a polymer lift-off technique.

We present a new method for creating patches of fluid lipid bilayers with conjugated biotin and other compounds down to 1 microm resolution using a photolithographically patterned polymer lift-off technique. The patterns are realized as the polymer is mechanically peeled away in one contiguous piece in solution. The functionality of these surfaces is verified with binding of antibodies and avidin on these uniform micron-scale platforms. The biomaterial patches, measuring 1 micro m-76 microm on edge, provide a synthetic biological substrate for biochemical analysis that is approximately 100x smaller in width than commercial printing technologies. 100 nm unilamellar lipid vesicles spread to form a supported fluid lipid bilayer on oxidized silicon surface as confirmed by fluorescence photobleaching recovery. Fluorescence photobleaching recovery measurements of DiI (1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiIC(18)(3))) stained bilayer patches yielded an average diffusion coefficient of 7.54 +/- 1.25 microm(2) s(-1), equal to or slightly faster than typically found in DiI stained cells. This diffusion rate is approximately 3x faster than previous values for bilayers on glass. This method provides a new means to form functionalized fluid lipid bilayers as micron-scale platforms to immobilize biomaterials, capture antibodies and biotinylated reagents from solution, and form antigenic stimuli for cell stimulation.

Adsorption↗

Study of intrinsic localized vibrational modes in micromechanical oscillator arrays.

Intrinsic localized modes (ILMs) have been observed in micromechanical cantilever arrays, and their creation, locking, interaction, and relaxation dynamics in the presence of a driver have been studied. The micromechanical array is fabricated in a 300 nm thick silicon-nitride film on a silicon substrate, and consists of up to 248 cantilevers of two alternating lengths. To observe the ILMs in this experimental system a line-shaped laser beam is focused on the 1D cantilever array, and the reflected beam is captured with a fast charge coupled device camera. The array is driven near its highest frequency mode with a piezoelectric transducer. Numerical simulations of the nonlinear Klein-Gordon lattice have been carried out to assist with the detailed interpretation of the experimental results. These include pinning and locking of the ILMs when the driver is on, collisions between ILMs, low frequency excitation modes of the locked ILMs and their relaxation behavior after the driver is turned off.

Journal Article↗

An electrospray ionization source for integration with microfluidics.

We have demonstrated a new electrospray ionization (ESI) device incorporating a tip made from a shaped thin film, bonded to a microfluidic channel, and interfaced to a time-of-flight mass spectrometer (TOFMS). A triangular-shaped thin polymer tip was formed by lithography and etching. A microfluidic channel, 20 microm wide and 10 microm deep, was embossed in a cyclo olefin substrate using a silicon master. The triangular tip was aligned with the channel and bonded between the channel plate and a flat plate to create a microfluidic channel with a wicking tip protruding from the end. This structure aided the formation of a stable Taylor cone at the apex of the tip, forming an electrospray ionization source. This source was tested by spraying several solutions for mass spectrometric analysis. Because the components are all made by lithographic approaches with high geometrical fidelity, an integrated array system with multiple channels can be formed with the same method and ease as a single channel. We tested a multichannel system in a multiplexed manner and showed reliable operation with no significant cross contamination between closely spaced channels.

Cytochrome c Group↗