PubMed Health⌕ Search

Biomedical subjects

H Garan

Publications and source records attributed to H Garan.

At least 19 recordsLinked to original sources

Long-term infection rates associated with the pectoral versus abdominal approach to cardioverter- defibrillator implants.

Infection is an uncommon (0% to 6.7%) but serious complication after implantable cardioverter-defibrillator (ICD) implantation. All ICD primary implants, replacements, or revisions performed at the Massachusetts General Hospital between April 1983 and May 1999 were reviewed. A total of 21 ICD-related infections (1.2%) were identified among 1,700 procedures affecting 1.8% of the 1,170 patients who underwent a primary implant, a generator change, or a revision of their systems. The mean follow-up time was 35 +/- 33 months. Of the 959 patients with long-term follow-up, 19 of the 584 patients (3.2%) with abdominal and 2 of the 375 patients (0.5%) with pectoral systems developed ICD-related infections (p = 0.03). There was no significant difference between the infection rate among the 959 primary ICD implants and the 447 replacements or system revisions. Only 5 of the patients (24%) had systemic signs of infection, including fever (T>100.5) and elevated white blood count >12,000. Cultures from the wound revealed staphylococcal species in 16 patients (76%). Nineteen patients were treated with removal of the entire ICD system in addition to intravenous antibiotics for 2 to 4 weeks. A decrease in the incidence of ICD-related infection has occurred since the advent of transvenous pectoral systems. The main organism responsible for ICD infection is Staphylococcus. The mainstay of ICD infection management consists of complete removal of the entire implanted system.

Antibiotic Prophylaxis↗

Long-term clinical outcome of patients with prior myocardial infarction after palliative radiofrequency catheter ablation for frequent ventricular tachycardia.

Patients with coronary artery disease and hemodynamically tolerated, highly frequent, sustained monomorphic ventricular tachycardia (VT) may undergo radiofrequency catheter ablation (RFCA) for elimination of > or = 1 morphologically distinct VTs. The purpose of this study was to evaluate the long-term clinical benefit following RFCA as a palliative treatment of highly frequent or incessant ischemic VT. Fifty-five patients underwent RFCA of 62 VTs. The target VT was successfully ablated in 82% of patients. Complication and perioperative mortality rates were 7.2% and 1.8%, respectively. At 5 years, total mortality was 51% and probability of freedom from all ventricular tachyarrhythmias was 28%. All patients had highly frequent or incessant drug-refractory VT before RFCA. Clinical benefit was defined as either freedom from all ventricular tachyarrhythmias, or a reduction in frequency of recurrence from > 1 episode per month before RFCA to < or = 1 episode per year of any ventricular tachyarrhythmia, including all appropriate implantable cardioverter defibrillator (ICD) therapies. By this definition, 54% of the patients continued to benefit from RFCA at 5 years. Of 19 variables analyzed with a Cox univariate model, only the presence of a left ventricular aneurysm and a previously implanted ICD were predictive of any ventricular arrhythmia recurrence. However, at 5 years over half of the surviving patients still continued to benefit from RFCA of their clinical VT. Because the overall rate of any ventricular tachyarrhythmia occurrence during follow-up is high, additional protection, such as an ICD, is required.

Aged↗

Mechanism of sustained monomorphic ventricular tachycardia in systemic sclerosis.

Three patients with advanced systemic sclerosis and recurrent or incessant monomorphic ventricular tachycardia underwent cardiac electrophysiologic studies. Biventricular transcatheter mapping showed findings most compatible with a reentrant mechanism, which was effectively treated with transcatheter ablation.

Electrocardiography↗

Transvenous single lead atrial defibrillation: efficacy and risk of ventricular fibrillation in an ischemic canine model.

Transvenous atrial defibrillation with multiple atrial lead systems has been shown to be effective in models without the potential for ventricular arrhythmias. The specific aim of this study was to evaluate the efficacy and safety of transvenous single lead atrial defibrillation in a canine model of ischemic cardiomyopathy. Ten dogs had ischemic cardiomyopathy induced by repeated intracoronary microsphere injections. The mean LV ejection fraction decreased from 71% +/- 9% to 38% +/- 14% (P = 0.003). Spontaneous atrial fibrillation (AF) developed in four dogs, and in six AF was induced electrically. Atrial defibrillation thresholds (ADFTs) were determined with synchronous low energy shocks using a transvenous tripolar lead with two defibrillation coils (right ventricle, superior vena cava) and an integrated sensing lead (RV coil vs electrode tip). The ADFTs derived by logistic regression were compared at 50% and 90% probability of success (ED50, ED90): ED50 was 2.4 +/- 1.7 J and 2.9 +/- 2.1 J, respectively, for 5- and 10-ms monophasic shocks, and 1.8 +/- 0.9 J, respectively, for 5- and 10-ms biphasic shocks. Immediately after 3 of 2,179 (0.1%) synchronized shocks, ventricular fibrillation (VF) developed. VF was induced in 3 of 1,062 (0.3%) shocks with integrated sensing (RV coil vs electrode tip) compared to 0 of 1,117 shocks when a separate bipolar RV sensing electrode was used for synchronization. In our canine model of ischemic cardiomyopathy, low energy atrial defibrillation via a transvenous single lead system was highly effective. However, there was a small but definite risk of VF induction, which seemed to be greater when an integrated as opposed to a true bipolar RV sensing was used.

Animals↗

Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival.

OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.

Arrhythmias, Cardiac↗

The treatment of patients with infected implantable cardioverter-defibrillator systems.

OBJECTIVE: The purpose of this study was to evaluate the treatment of patients with infected implantable cardioverter-defibrillator systems. METHODS: Retrospective analysis was done of the cases of 21 patients treated for implantable cardioverter-defibrillator infection during an 11-year period. RESULTS: Of 723 cardioverter-defibrillator implantations (550 primary implants, 173 replacements), nine (1.2%) were complicated by early postoperative device-related infections. Late infections developed in two patients 19 and 22 months, respectively, after implantation. Ten other patients were transferred to our institution for treatment of cardioverter-defibrillator infection. The time from implantation to overt infection was 2.2 +/- 1.3 months, excluding the two late infections. The responsible organisms were Staphylococcus aureus (9), Staphylococcus epidermidis (6), Streptococcus hemolyticus (1), gram-negative bacteria (3), Candida albicans (1), and Corynebacterium (1). All patients were treated with intravenous antibiotic drugs. Total system removal was done in 15 patients and partial removal in 2; in 4, the cardioverter-defibrillator system was not explanted. There were no perioperative deaths. A new implantable cardioverter-defibrillator system was reimplanted in 7 patients after 2 to 6 weeks of antibiotic therapy. Ten patients were treated without reimplantation (2 arrhythmia operation, 8 antiarrhythmic drugs). Four patients (3 patients without explantation and 1 with partial system removal) were treated with maintenance long-term antibiotic therapy. During a mean follow-up of 21 +/- 2.8 months, no patient had clinical recurrence of infection. One patient treated with antiarrhythmic drugs without system reimplantation died suddenly. CONCLUSIONS: Infections that involve implantable cardioverter-defibrillator systems can be safely managed by removing the entire system with reimplantation after intravenous antibiotic therapy. In selected patients in whom the risk for system explantation is high and anticipated life expectancy is short, long-term antibiotic therapy to suppress low-virulence infections may represent an acceptable alternative.

Adult↗

Transient right bundle branch block causing R wave attenuation postdefibrillation.

Transient and significant decrease in R wave amplitude, associated with transient right bundle branch block, was noted to occur after defibrillation in a defibrillator patient. The mechanism is probably stunning of the right bundle branch, causing right intraventricular conduction delay and decrease in signal amplitude reaching the endocardial sensing dipoles.

Bundle-Branch Block↗

Mechanisms underlying different surface ECG morphologies of recurrent monomorphic ventricular tachycardia and their modification by procainamide.

INTRODUCTION: Distinct surface ECG morphologies (ECGMs), from one episode to the next, of recurrent monomorphic ventricular tachycardia (VT) in the same patient complicate endocardial catheter mapping and the success of ablative therapy. This study investigates the incidence and mechanisms of multiple ECGMs during recurrent monomorphic VTs in a canine model of experimental myocardial infarction (MI). METHODS AND RESULTS: Computerized ECG analysis and simultaneous endocardial and epicardial activation mapping with a 64 bipolar electrode array were used to analyze the relation between site of VT origin, local activation sequence, and surface ECGM in 72 VT episodes induced in 9 of 17 dogs with experimental MI. Pairwise comparisons of all VTs induced in the same animal were done in drug-free state (47 VTs) and after intravenous procainamide (25 VTs). In drug-free state, VT pairs with similar surface ECGMs manifested endocardial breakthrough sites (BSs) within a distance < 10 mm in 46 (100%) of 46 VT pairs compared to 43 (45%) of 95 VT pairs with different surface ECGMs (P < 0.0001). Of all 89 VT pairs with endocardial BSs within < 10 mm, similar endocardial activation patterns were found in 34 (74%) of 46 pairs with similar ECGMs in contrast to 6 (14%) of 43 pairs with different ECGMs (P < 0.001). Similar comparisons of VT pairs induced after intravenous procainamide administration showed that the endocardial BSs were located within < 10 mm in 9 (75%) of 12 VT pairs with similar and in 17 (49%) of 95 with different surface ECGMs, respectively (P = NS). CONCLUSIONS: In the same heart, similar surface ECGMs of recurrent VT are highly predictive of closely spaced endocardial BSs in drug-free state, but not after procainamide administration. Nearly half of the VTs with different surface ECGMs still originate from closely spaced endocardial BSs but commonly manifest a change in the endocardial activation spread from this site. Thus, assumptions about different mechanisms and sites of VT origin based on different surface ECGMs should be made with caution.

Animals↗

Reproducible induction of "atypical" torsades de pointes by programmed electrical stimulation: a novel form of sotalol-induced proarrhythmia?

We present a patient with sotalol-induced polymorphic ventricular tachycardia that was seen only with programmed ventricular stimulation. Electrophysiologic studies performed prior to initiation of sotalol therapy revealed inducible monomorphic ventricular tachycardia. Possible underlying electrophysiologic mechanisms are discussed.

Anti-Arrhythmia Agents↗

Internal atrial defibrillation: lessons learnt from experimental studies.

Following the introduction of a transvenous biatrial electrode configuration and a biphasic waveform for internal atrial defibrillation in patients in 1992, it was realized that the standard principles of efficient defibrillation derived from decades of ventricular defibrillation research would not provide painless atrial defibrillation in conscious patients. Over the last five years extensive experimental studies have addressed the risk of ventricular proarrhythmia from synchronized atrial shocks with reassuring results and the influence of the preceding R-R interval on the safety of atrial shocks has been established. Experimental atrial defibrillation research is now aimed at developing waveforms which are less painful and at exploring hybrid therapies including percutaneous right atrial compartmentalization by catheter ablation prior to atrial defibrillation and attempts at multisite pace-entrainment prior to and immediately following the delivery of perithreshold shocks.

Animals↗

Influence of the implantable cardioverter/defibrillator on sudden death and total mortality in patients evaluated for cardiac transplantation.

BACKGROUND: Implantable cardioverter/defibrillators (ICDs) may reduce sudden tachyarrhythmic death in patients with severe left ventricular dysfunction. It is uncertain whether this improves survival, particularly in patients awaiting cardiac transplantation. METHODS AND RESULTS: The effect of treatment for spontaneous ventricular arrhythmias (ICD [n = 59], antiarrhythmic drugs [n = 53], or no antiarrhythmic treatment [n = 179]) on total mortality and mode of cardiac death was analyzed in 291 consecutive patients evaluated for cardiac transplantation between January 1986 and January 1995. There were 109 deaths (37.4%) (63 [21.6%] sudden, 40 [13.7%] nonsudden, and 6 [2.1%] noncardiac) during mean follow-up of 15 months (range, 1 to 118 months). Baseline clinical variables, medical therapies for heart failure, and actuarial rates of transplantation were similar between treatment groups. Kaplan-Meier sudden death rates were lowest in the ICD group, intermediate in the no antiarrhythmic treatment group, and highest in the drug treatment group throughout follow-up (12-month sudden death rates, 9.2%, 16.0%, and 34.7%, respectively; P = .004). Total mortality and nonsudden death rates did not differ. Cox proportional-hazards model revealed that antiarrhythmic drug treatment was associated with sudden death (relative risk, 2.1; 95% CI, 1.04 to 3.39; P = .04) and ICD was associated with nonsudden death (relative risk, 2.26; 95% CI, 1.12 to 4.62; P = .02). CONCLUSIONS: Sudden death rates were lowest in patients treated with ICDs compared with drug treatment or no antiarrhythmic treatment. However, although ICDs reduced sudden death in selected high-risk patients with severe left ventricular dysfunction, the effect on long-term survival was limited, principally by high nonsudden death rates.

Actuarial Analysis↗

Electrocardiographic pseudo-infarct patterns after implantation of cardioverter-defibrillators.

Postoperative electrocardiographic (ECG) changes are frequently present after insertion of implantable cardioverter-defibrillators (ICD) and may mimic perioperative myocardial infarction (MI). The purpose of this study was to assess the incidence and clinical significance of postoperative ECG changes in relation to clinical, laboratory, and implantation data. In 25 (16%) of 156 patients undergoing ICD implantation, significant ECG changes (> or = 50% reduction in R-wave amplitude in > or = 3 leads or new Q waves in > or = 2 leads) were present 1 to 3 days after the operation and persisted at hospital discharge in 12 (8%). Presence of thoracotomy, the total number of induced ventricular fibrillation episodes, and the number of defibrillation shocks required during defibrillation threshold (DFT) testing correlated with postoperative ECG changes. Other factors associated with a significant R-wave loss in the lateral precordial leads included left-sided pleural effusion, lung infiltrates or atelectasis, and large defibrillator patch electrodes over the left ventricle or the lateral chest wall. Myocardial necrosis documented by elevated cardiac enzymes occurred in 6 (5%) of 151 patients without significant ECG changes and in 3 (12%) with (p value not significant). However, postoperative ECG changes associated with elevated enzymes were indistinguishable from changes unrelated to necrosis. Therefore the sensitivity and specificity of the surface ECG for detection of MI after ICD placement is poor. Multiple factors such as thoracotomy, myocardial injury from DFT testing, electric insulation, or shielding of the heart may contribute to the development of electrocardiographic pseudo-infarct patterns.

Aged↗

Implantation of transvenous nonthoracotomy cardioverter-defibrillator systems in patients with permanent endocardial pacemakers.

Among 177 patients in whom a nonthoracotomy approach was initially used to implant a cardioverter-defibrillator system, 11 (6%) patients also received a separately implanted permanent pacemaker. The main problem encountered in these patients were previously implanted unipolar pacemakers (n = 3) and ventricular pacing leads positioned at the right ventricular apex, the latter interfering with optimal placement of the tripolar implantable cardioverter-defibrillator (ICD) lead (n = 9). The approaches used to solve these problems were individualized and included placement of the ICD sensing lead at the right ventricular outflow tract (n = 3), initial placement (n = 1) or subsequent repositioning (n = 2) of the right ventricular pacing lead at the outflow tract, upgrade from unipolar to bipolar systems (n = 2), reprogramming from the DDD to AAI mode (n = 2), inactivation of the pacemaker (n = 1), and simultaneous placement of a single-chamber atrial pacemaker with the ICD lead (n = 2). These revisions fulfilled the pacing needs in each patient and prevented unfavorable sensing interaction between the two systems.

Aged↗

Ventricular pacing induced ventricular tachycardia in patients with implantable cardioverter defibrillators.

Appropriately timed noncompetitive ventricular pacing potentially may initiate ventricular tachycardia in patients prone to these arrhythmias. The combination of bradycardia pacing and stored electrograms in a currently available cardioverter defibrillator provides an opportunity to evaluate the occurrence of such pacing induced ventricular tachycardia. During a surveillance period of 18.7 +/- 11.4 months, stored electrograms documented 302 episodes of ventricular tachycardia in 77 patients. Five patients (6.5%) demonstrated 25 episodes (1-16 per patient) of ventricular tachycardia that were immediately preceded by an appropriately paced ventricular beat (8.3% of all episodes of ventricular tachycardia). All five patients had prior myocardial infarctions and a history of monomorphic ventricular tachycardia occurring both spontaneously and in response to programmed electrical stimulation. Antitachycardia pacing terminated pacing induced ventricular tachycardia in 22 episodes; in one episode antitachycardia pacing accelerated ventricular tachycardia. In two cases shock therapy was aborted for nonsustained ventricular tachycardia. We conclude that, in selected nonsustained ventricular tachycardia. We conclude that, in selected postinfarction patients with recurrent sustained monomorphic ventricular tachycardia treated with implantable cardioverter defibrillators, appropriately timed ventricular pacing may induce ventricular tachycardia.

Aged↗