[Gernet and GOW-70-Program intraocular lens calculation. Significance of the of the position of the principal plane of the lens in phakic and pseudophakic eyes for accuracy of the target refraction of different IOL types].

The GOW 70 PC programme utilises the individual bio-anatomy of the phacic cataract eye in the IOL power calculation for multifocal or monofocal in-the-bag-implantation for all common IOL types. In addition, an aniseiconia evaluation programme is included. The Gernet IOL power calculation is based on the GOW 70, 71 formulae which consists of the PC programme (one disc), one table (the 60% rule), an instruction for use in personal computers (Windows, Word) and in the 60% procedure. This is based on ultrasound immersion measurements of about 20,000 phacic eyes with and without cataracts and after 2,000 IOL implantations by various surgeons using the d-values of the human eye lenses of the cataract eye and the d-values of the IOL types used. The d-value of a phacic eye is the distance between the corneal vertex and the principal plane (infinitely thin lenses) of the human eye lens and is formed from the depth of the anterior segment (cornea + AC) + 60% of the human lens thickness. The d-value of a pseudophacic eye is the distance between the corneal vertex and the principal plane of the chosen IOL type. In 1984, the first definite clinical connection between the d-values of human eye lenses and of implanted PC IOL (6.0 mm-1.5 mm = 4.5 mm) was established. In 1992 and 1998 it was extended to the "newer" 60% rule and to the 60% procedure, respectively.

Biometry↗

[Axial echometry of the eye. Results and possible clinical applications].

This survey describes ultrasound measurement techniques and echograms of living phakic and cataract eyes. Results of clinical echometry on emmetropic and ametropic eyes are reported. In unilateral or bilateral cataract and in unilateral aphakia, appropriate ultrasound measurements are of fundamental importance for restoring compatible vision; in unilateral aphakia, by means of combinations of contact lenses and spectacles; in cataract, by means of precalculated artificial intraocular lenses.

Anthropometry↗

[Precalculated artificial lenses in ametropia (author's transl)].

The main sources of error in a successful precalculated artificial lens implantation in ametropia are inaccurate ultrasound measurements, inadequate calculation procedures, rules, suggestions and confidence in the accuracy of Knapp's law. In ametropia of -6.0 D to +4.0 D a precalculated lens implantation according to our three principles (uncorrected good vision, compatible aniseikonia, large retinal images) results in good vision with one and/or two artificial intraocular lenses.

Humans↗

Precalculated artificial lens implantation with refractive balance.

The two main possibilities of error of the generally used methods for artificial lens implantation after preoperative ultrasound measurements and calculations are discussed. By using our additional special calibration to the ultrasonic equipment we can predict the postoperative refraction with an error of +/- 0.5 D corresponding to an uncorrected vision of about 20/40 and better. Procedures based on the validity of Knapp's law may lead to optical pitfalls, since Knapp's law is only valid for eyes with variable eye length, while it is known that human phakic, pseudophakic and aphakic eyes have a constant eye length. Three principles for the precalculated artificial lens implantation are published and results of refractive balances are given.

Calibration↗

The binocular confusion in unilateral aphakia.

The first 4 symptoms of binocular confusion concern primarily daytime vision and the fifth symptom concerns nighttime vision. Even with a conventional contact lens correction, symptoms of binocular confusion occur, especially with high optical aniseikonia for near or far distance. In addition, diplopia occurs in the presence of strabismus. The important result of our research is the fact that unilateral aphakes are severely disturbed by the 5 symptoms of binocular confusion described above. These disturbances can be eliminated completely with an appropriate spectacle-contact lens combination based on echometry and intraocular optics.

Adult↗

[Unilateral aphakia in juveniles. Results of combined correction (author's transl)].

Eighty-one unilateral aphakies under 45 years of age, 63 of which had suffered an injury, were analyzed by echometry and intraocular optics. With the aid of a computer, the majority of cases were treated for restoration of nearly equal images in both eyes by combined correction, i.e., an appropriate spectacle -- contact lens combination with both distant and near vision in the aphakie eye taken into consideration. Results with unilateral post-traumatic aphakia (63 cases) : 31 patients with uncorrected vision and 42 with a conventional contact lens suffered from symptoms of binocular confusion as opposed to only one patient with combined correction. Of the 63 patients with uncorrected vision or with a conventional contact lens, 44 had strabismus. After optimal treatment with combined correction, with or without subsegment strabismus surgery, 19 out of 23 patients were cured of their strabismus and regained a useful and comfortable, distant and near binocular vision. Thus, for juvenile unilateral aphakics, a rather good prognosis was achieved by combined correction.

Adolescent↗

[Binocular confusion in unilateral aphakia (author's transl)].

The five symptoms of binocular confusion of the unilateral aphakic patient are described. In day vision, without strabismus and without correction, the image of the aphakic eye considerbly disturbs binocular vision, though the vision is less than 20/400 (first symptom). In night traffic the uncorrected unilateral aphakic patient sees very striking light circles and within those circles of glittering dots around bright light sources of cars or around blinking indicators and stoplights (fifth symptom). The five disturbing symptoms of binocular confusion can be positivity eliminated by an appropriate combination of spectacles and contact lens (combined correction) in regard to echometry and intraocular optics.

Adolescent↗

[Uniocular aphakia--conventional contact lenses and aniseikonia].

Ehrich and Kolbegger show in their papers that aniseikonia should not prevent binocular functions in a uniocular aphakia. This is contrary to our own experiences. In this paper we suggest that the results of Ehrich and Kolbegger must be worse in spite of their final conclusions. Their hypotheses are discussed.

Aniseikonia↗

[Contribution on the infraocular optics (author's transl)].

Experience indicates that a person will have a comfortable vision only if the sizes of the image in both eyes are approximately equal; a tolerance of approximately 5% is acceptable for this. In other words both optical systems, consisting of a spectacle lens, a contact lens, and the eye must have approximately the same focal length. Patients who have one phacic and one aphacic eye will usually possess quite different focal lengths with conventional contact lens correction. However, with the addition of spectacles and of appropriate contact lenses on one or both eyes, the ophthalmologist has at his disposal a new variable. The given formulas and rules of thumb enable him to choose the strength of spectacles-contact lens combinations so that the patient will also have sharp vision in both eyes and regain a comfortable binocular sight. The method is illustrated by examples.

Contact Lenses↗