Therapeutic drug monitoring of the HIV/AIDS drugs abacavir, zidovudine, efavirenz, nevirapine, indinavir, lopinavir, and nelfinavir.

Combination therapy with antiretroviral drugs is used for the treatment of patients infected with the human immunodeficiency virus. To achieve optimal drug concentrations for viral suppression and avoidance of drug toxicity, monitoring of drug levels has been considered essential. We set up an analytical procedure for monitoring the plasma concentrations of a total of seven drugs: abacavir, zidovudine, efavirenz, nevirapine, indinavir, lopinavir, and nelfinavir. The plasma samples were liquid/liquid extracted and subjected to high-performance liquid chromatography (HPLC) analysis. The compounds were monitored by ultraviolet detection: indinavir, lopinavir, and nelfinavir at 215 nm; efavirenz at 254 nm, and abacavir, zidovudine, and nevirapine at 266 nm. Two different extraction procedures and two different HPLC eluents on a C(8) reversed-phase HPLC column were used to monitor all seven compounds. Under steady state conditions, the plasma concentrations of antiviral drugs in 175 patients were correlated with the time after the last dosing to define the peak or trough levels. Due to the short plasma elimination half-life of abacavir and zidovudine, only peak levels could be determined for these compounds, whereas both peak and trough levels could be assessed for the other compounds because of a longer plasma elimination half-life. The mean peak concentrations (microg/ml) were 0.69 for abacavir and 0.57 for zidovudine; the mean peak/trough concentrations (microg/ml) were 2.07/1.32 for efavirenz, 2.43/2.23 for nevirapine, 5.48/1.08 for indinavir, 4.69/3.51 for lopinavir, and 3.54/1.45 for nelfinavir. The described analytical method offers a broad-spectrum monitoring of plasma levels of antiretroviral drugs.

Anti-HIV Agents↗

Qualitative detection of Legionella species in bronchoalveolar lavages and induced sputa by automated DNA extraction and real-time polymerase chain reaction.

Molecular assays for qualitative detection of Legionella spp. in clinical specimens were evaluated. DNA extraction was done either with a fully automated DNA extraction protocol on the MagNA Pure LC System or with manual DNA extraction. Amplification and detection were done by real-time polymerase chain reaction (PCR) on the LightCycler (LC) instrument. Oligonucleotides were derived from the 16S rRNA gene of Legionella spp. The assays included a specially designed DNA fragment as Legionella-specific internal control. For both molecular assays, the detection limit was determined to be 5 CFU per LC PCR run. Sixty-one clinical specimens were tested with the molecular assays. Results were compared to culture. Five samples were found to be positive with the molecular assays. Three of them were positive in culture. No inhibition was found throughout the whole study. In conclusion, the molecular assays described may lead to safe and early diagnosis of Legionnaires' disease. They proved to be suitable for the routine molecular diagnostics laboratory.

Adult↗

Cytomegalovirus diagnosis in renal and bone marrow transplant recipients: the impact of molecular assays.

BACKGROUND: Cytomegalovirus (CMV) infections are a major threat in transplant recipients. In recent years, new assays for routine CMV diagnosis, based on molecular techniques, have become available. OBJECTIVE: The impact of molecular assays for CMV diagnosis in transplant recipient was evaluated. STUDY DESIGN: A total of 51 transplant recipients were screened for CMV infection. Serological (AxSYM CMV IgG and recombinant CMV IgM assays), antigenemia, CMV DNA (qualitative in house PCR and the quantitative COBAS AMPLICOR CMV MONITOR Test), and CMV mRNA (NucliSens CMV pp67 Test) tests were compared. RESULTS: In 11/20 bone marrow transplant (BMT) recipients and 10/31 renal transplant (RTX) recipients there was no evidence of active CMV infection. Ten RTX recipients and one BMT recipient were antigenemia positive, 21 RTX and seven BMT recipients were PCR positive (qualitative CMV PCR). There were more BMT recipients CMV DNA positive in serum (7/21) than antigenemia positive (1/21). CMV mRNA was found positive in two BMT recipients (one case with no other evidence of CMV infection, the other one CMV DNA positive and antigenemia negative). The only antigenemia positive BMT recipient was found negative for CMV mRNA, but positive in all other tests. Eight RTX recipients were found positive for CMV mRNA. Six of them were also antigenemia positive and five of those were also found positive for CMV IgM. One CMV mRNA positive RTX recipient was CMV IgM positive but antigenemia negative and the other one CMV mRNA positive RTX recipient was found negative in all other tests. Two antigenemia positive RTX recipients were found negative for mRNA and CMV IgM. CONCLUSION: Antigenemia was found to be a good screening test for CMV infection in RTX recipients. In BMT recipients, tests based on molecular techniques appeared to be superior compared to antigenemia.

Adolescent↗

Determination of human immunodeficiency virus type 1 subtypes by a rapid method useful for the routine diagnostic laboratory.

The existence of human immunodeficiency virus type 1 (HIV-1) subtypes has many important implications for the global evolution of HIV and for the evaluation of pathogenicity, transmissibility, and candidate HIV vaccines. The aim of this study was to establish a rapid method for determination of HIV-1 subtypes useful for a routine diagnostic laboratory and to investigate the distribution of HIV-1 subtypes in Austrian patients. Samples were tested by a subtyping method based on a 1.3-kb sequence of the polymerase gene generated by a commercially available drug resistance assay. The generated sequence was subtyped by means of an HIV sequence database. Results of 74 routine samples revealed subtype B (71.6%) as the predominant subtype, followed by subtype A (13.5%) and subtype C (6.8%). Subtypes E, F, G, and AE (CM240) were also detected. This subtyping method was found to be very easy to handle, rapid, and inexpensive and has proved suitable for high-throughput routine diagnostic laboratories. The specific polymerase gene sequence, however, must be existent.

Child↗

Effects of storage and type of blood collection tubes on hepatitis C virus level in whole blood samples.

In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at "date zero." In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport.

Adult↗

Identification of different states of hepatitis B virus infection with a quantitative PCR assay.

The level of hepatitis B virus (HBV) DNA in serum reflects the replicative activity of HBV. To compare serum HBV DNA levels in different states of hepatitis B, 47 sera of patients with HBeAg-positive chronic hepatitis B, 4 sera of patients with HBeAg-negative chronic hepatitis B, 40 samples of patients after HBeAg seroconversion during alpha interferon treatment, 57 sera of inactive HBsAg carriers, and 42 sera of patients who had recovered from chronic hepatitis B more than 12 months prior to blood collection were checked for the presence of HBV DNA with the Amplicor HBV Monitor Test. In patients with HBeAg-positive chronic hepatitis B, the median of serum HBV DNA levels (8.3 x 10(8) copies/ml) was significantly higher than that for patients after HBeAg seroconversion (6.2 x 10(3) copies/ml) and than that for inactive HBsAg carriers (5.6 x 10(3) copies/ml). None of the patients who had recovered from hepatitis B had detectable HBV DNA in serum. Quantitative PCR proved to be a valuable tool for identification of different states of HBV infection. This technique was found to be a good method for determination of serum HBV DNA levels both for patients with HBeAg seroconversion and for inactive carriers who showed low viremia not detectable by conventional hybridization assays.

Adolescent↗

Semiautomated quantification of hepatitis B virus DNA in a routine diagnostic laboratory.

The Cobas Amplicor HBV Monitor test for quantitative determination of hepatitis B virus (HBV) DNA in serum has recently been introduced. To evaluate the performance of this assay in a routine diagnostic laboratory, reproducibility of results was determined with the First European Union Concerted Action HBV Proficiency Panel and the Accurun 325 HBV DNA Positive Control, Series 300. Results for 270 routine serum samples were additionally evaluated. To avoid the retesting of a large number of samples due to titers exceeding the upper limit for the linear range of the assay, sera of patients with chronic hepatitis B (CHB) were diluted prior to the assay to 10(-4) in normal human plasma, which is included in the assay. The mean coefficient of variation was 22.9% for all input HBV DNAs. Of 270 routine serum samples, 182 (150 sera from transplant donors and 32 sera from patients who had recovered from CHB) tested negative. Eighty-six sera were found to be HBV DNA positive; in six sera, HBV DNA levels were found to exceed the upper limit for the linear range of the assay and had to be retested. In the remaining two sera, inhibition occurred. The semiautomated Cobas Amplicor HBV Monitor test showed sufficient reproducibility and helped in avoiding human error. The relatively narrow linear range of detection is a limitation of the new assay.

Automation↗

Detection of Herpes simplex virus DNA by real-time PCR.

Molecular detection of herpes simplex virus (HSV) DNA is recognized as the reference standard assay method for the sensitive and specific diagnosis of central nervous system infections caused by HSV. In this study, a molecular assay based on real-time PCR on the LightCycler (LC) instrument was evaluated and compared with a home-brew molecular assay. The detection limit of the LC assay was determined with 10-fold dilutions of plasmid pS4 with the SalI restriction fragment of the DNA polymerase gene and with the First European Union Concerted Action HSV Proficiency Panel. A total of 59 cerebrospinal fluid (CSF) specimens were investigated for the comparative study. With plasmid pS4, the detection limit of the LC assay was found to be 10(4) copies per ml, i.e., 12.5 copies per run. When samples of the First European Union Concerted Action HSV Proficiency Panel were tested, 2x10(3) to 5x10(3) HSV type 1 genome equivalents (GE) per ml, i.e., 2.5 to 6.3 GE per run, could consistently be detected. There was a correlation between the LC assay and the home-brew assay in 55 of 59 specimens. In conclusion, the LC assay allows very rapid detection of HSV DNA in CSF. It was found to be laborsaving and showed sufficient sensitivity.

Adult↗

Interferon-alpha and ribavirin in treating children and young adults with chronic hepatitis C after malignancy.

OBJECTIVE: Chronic hepatitis C is a major long-term problem for children who survive cancer. Interferon (IFN)-alpha has been shown to be effective in treating patients with chronic hepatitis C; however, the rate of sustained response is low. Combining IFN-alpha and ribavirin (RBV) has been shown to significantly improve the response in adult patients with chronic hepatitis C. The aim of this pilot study was to evaluate the efficacy and safety of a combined virostatic treatment with IFN-alpha and RBV in a small cohort of children and adolescents with chronic hepatitis C and previous malignancy. METHODS: Twelve patients with a history of a hematooncologic disease (median follow-up: 13.5 years; range: 7-14.7 years) and chronic hepatitis C were treated with recombinant IFN-alpha-2a (6 megaunits/m(2) body surface area, 3 times a week, subcutaneously) combined with RBV (15 mg/kg body weight/day, orally) for 12 months. They were tested monthly for blood counts and liver function, and for serum virus concentrations (hepatitis C virus RNA by polymerase chain reaction) every 3 months. RESULTS: At the end of the treatment, hepatitis C virus RNA could not be detected in the serum of 8 of the 12 patients; 2 of these patients relapsed soon after therapy withdrawal, whereas 6 patients maintained in sustained virologic and biochemical remission (follow-up: 12 months). Treatment-induced toxicity was moderate and reversible with influenza-like symptoms and a decrease in blood counts in all 12 patients, alopecia in 5 of the 12, hemolysis in 4 of the 12, and weight loss of >10% in 2 of the 12. CONCLUSIONS: As demonstrated in adults with chronic hepatitis C, treatment with IFN-alpha and RBV also seems to be an effective and safe therapeutic option for children and adolescents with chronic hepatitis C after malignancy.

Adolescent↗

Is IgM of diagnostic value in case of delayed intrathecal production of IgG antibodies?

The neurological manifestations of Lyme borreliosis comprise a wide range of clinical signs. However, these symptoms might have other aetiologies. Therefore detection of intrathecal production of specific antibodies is necessary to confirm the clinical assumption of neuroborreliosis (NB). In case of delayed intrathecal production of specific IgG antibodies, detection of IgM could play a role in the early diagnosis of NB. To clarify whether IgM is of diagnostic value in such cases, paired CSF serum samples from 176 patients with suspected NB admitted to the department of Neurology, Karl Franzens University, Graz, Austria, were tested. Testing was performed with the IDEA Neuroborreliosis Kit (Dako, Denmark) and Enzygnost Borreliosis (Behring, Germany) and results of both methods were compared. According to well defined criteria 63 of the 176 patients had defined NB and 113 were regarded as possible NB. Twelve out of 63 patients with defined NB had delayed intrathecal IgG production. Only one patient with delayed IgG production had an intrathecal IgM production prior to IgG. In all patients with possible NB no intrathecal production of IgM was detected. At the time of the first lumbar puncture IgG intrathecal production could be detected with the IDEA seven times more often than with the Enzygnost Borreliosis. The determination of intrathecal production of IgM does not appear to be of diagnostic value in patients with delayed IgG antibody production. Therefore a consecutive lumbar puncture is more likely to confirm clinical assumption if there is strong clinical evidence of NB.

Adult↗

Evaluation of AMPLILINK software for the COBAS AMPLICOR system.

The use of AMPLILINK version 1.0 software was evaluated for the operation and control of one COBAS AMPLICOR instrument and for two COBAS AMPLICOR instruments run simultaneously to perform and detect nucleic acid amplification reactions. A total of 3,384 results were analyzed. The initial accuracy of the results was 99.91%. Three errors of omission of transfer of data from the COBAS AMPLICOR to the AMPLILINK system were observed. Two of these errors were from a single specimen, where both the analyte and internal control results were not transmitted. These errors did not interfere with the correctness of any other data. There were no interruptions of runs, and no data were mixed. AMPLILINK increased convenience, saved labor, and was found to be a very useful addition for clinical laboratories performing molecular-diagnostic procedures with the COBAS AMPLICOR system.

Evaluation Studies as Topic↗

Evaluation of a new assay for HBV DNA quantitation in patients with chronic hepatitis B.

BACKGROUND: The Amplicor HBV Monitor Test for quantitative determination of serum hepatitis B virus (HBV) DNA has recently been introduced. This assay is based on PCR and a non-radioactive hybridization and detection system on microwell plates. OBJECTIVE: The performance of the Amplicor HBV Monitor Test was evaluated in a routine diagnostic laboratory. The Amplicor HBV Monoitor assay was compared to the Digene Hybrid Capture System HBV DNA assay for the quantitation of HBV in patient sera. STUDY DESIGN: Sensitivity and reproducibility were determined with 10-fold dilution series of two Eurohep HBV reference plasma specimens. Furthermore, 196 sera from 14 children with chronic HBV infection and interferon therapy were tested with both assays. RESULTS: The detection limit was found to be 10(3) copies/ml with the Amplicor PCR assay compared to 10(6) to 10(7) copies/ml with the Digene hybridization assay. Both assays were quasi-linear over the measurable ranges. The new PCR assay proved to be very reliable. With the Amplicor PCR assay, 26.2% of the HBV DNA-positive clinical samples were found between 10(3) and 10(7) copies/ml and all of them tested below the detection limit with the hybridization assay. CONCLUSION: The Amplicor HBV Monitor Test shows excellent sensitivity and provides a valuable tool for the detection of HBV DNA in serum. It can be used for recognizing those patients who might benefit from antiviral therapy, for evaluation of the efficacy of anti-HBV therapy, and for validation of blood products.

Child↗

Automation of polymerase chain reaction-based systems for detection of hepatitis C virus RNA.

Polymerase chain reaction-based molecular assays are gaining increasing importance in the diagnosis and monitoring of infectious diseases. Over the past several years, the development and application of these techniques has initiated a revolution in the diagnosis and monitoring of hepatitis C infection. Presently, molecular assays are exclusively done in especially dedicated laboratories. Advances in automation will bring these technologies into routine diagnostic laboratories and will make them widely used.

Automation↗

Quantitative detection of hepatitis B virus DNA with a new PCR assay.

The Amplicor HBV Monitor Test for quantitative detection of serum hepatitis B virus (HBV) DNA has recently been introduced. This assay is based on PCR and a non-radioactive hybridization and detection system on microwell plates. Evaluation in a routine diagnostic laboratory showed excellent sensitivity and adequate reproducibility; however, a more automated format would be desirable. The Amplicor HBV Monitor Test is useful for recognizing those patients who might benefit from antiviral treatment and for evaluation of the efficacy of anti-hepatitis B virus treatment.

DNA, Viral↗

Detection of antichlamydial antibodies in tears: a diagnostic aid?

OBJECTIVES: The antibody response in sera and tears of 167 patients with suspected chlamydial conjunctivitis was compared with the antibody response in sera and tears of 45 patients with symptoms of urogenital chlamydial infection to discover whether and which type of antichlamydial antibody detected in tears may be of diagnostic help in chlamydial conjunctivitis. METHODS: Diagnosis was based on chlamydial antigen detection from the conjunctiva and urogenital tract, done by a direct immunofluorescence assay, McCoy cell culture, and polymerase chain reaction. Additionally, antichlamydial immunoglobulin A (IgA) and immunoglobulin G (IgG) were determined in sera and tears of all patients by an immunoperoxidase assay. RESULTS: Two hundred twelve patients were examined--167 with conjunctivitis, 45 with symptoms of urogenital chlamydial infection. Cell culture, direct immunofluorescence assay, and polymerase chain reaction brought identical results. Conjunctival specimens taken from 33 (20%) of the patients with conjunctivitis were Chlamydia antigen positive; specimens taken from 134 (80%) were negative. Antichlamydial antibodies were found in tears of 29 (88%) of the patients with conjunctivitis whose specimens were Chlamydia antigen positive. Fifty-four (40%) of the patients with conjunctivitis whose specimens were Chlamydia antigen negative had antichlamydial antibodies in their tears. Twenty-five patients with urethritis (56%) were Chlamydia antigen positive in urethral swabs; 20 (44%) were negative. Antichlamydial antibodies were found in the tears of eight (32%) of the Chlamydia antigen-positive and two (10%) of the Chlamydia antigen-negative patients with urethritis. In contrast to patients with conjunctivitis, findings for patients with urethritis always were negative for antichlamydial IgG in the tears. CONCLUSION: Antichlamydial antibodies in tears were seen significantly more often in patients with conjunctivitis than in those with urethritis (P < or = 0.05). Antichlamydial IgG was found only in tears of patients with conjunctivitis. Therefore, the authors conclude that the detection of antichlamydial IgG in the tears might be helpful for diagnosis in patients with suspected chlamydial conjunctivitis who have antigen-negative conjunctival swabs.

Adolescent↗

Performance of the automated COBAS AMPLICOR system for the detection of hepatitis C virus RNA.

BACKGROUND: The COBAS AMPLICOR (CA) instrument for the amplification and detection steps of the AMPLICOR molecular diagnostic assays has recently been introduced. The system contains a single thermal cycler with two independently controlled heating/cooling blocks, a pipettor, a magnetic particle washer, a photometer and an incubator. OBJECTIVE: The performance of the CA instrument was evaluated in a routine diagnostic laboratory for the detection of hepatitis C virus (HCV) RNA. The new system was compared with the corresponding microwell plate assay (AMPLICOR HCV Test). STUDY DESIGN: Routine clinical sera (350) from hemodialysis patients and patients with chronic HCV infection and interferon therapy were studied. If discrepant results were obtained, both assays were repeated (specimen preparation, amplification and detection); in addition, the HCV copy number was determined with the AMPLICOR HCV MONITOR Test. RESULTS: There was a correlation between the CA HCV Test and the AMPLICOR HCV Test in 341 of 350 specimens (97%). After resolution of 9 discrepant results, the CA HCV Test gave a sensitivity of 97.8% and a specificity of 99.4%. The most common reason for discrepant results was a low HCV RNA copy number. CONCLUSION: The CA system was found to be a labor-saving, fast and reliable instrument for the amplification and detection steps of a RT-PCR molecular assay for detection of HCV RNA.

Flaviviridae Infections↗

Rapid diagnosis of enterovirus infection by a new one-step reverse transcription-PCR assay.

The AMPLICOR Enterovirus Test was evaluated with 103 cerebrospinal fluid (CSF) specimens. Twenty-seven CSF specimens were culture positive. With the AMPLICOR test, enterovirus RNA was detected in 34 specimens. Compared with culture, the AMPLICOR test gave a sensitivity of 96.3% and a specificity of 100%. The sensitivity of culture was 79.4% in comparison with the AMPLICOR test.

Enterovirus↗