Feasibility of using intensity-modulated radiotherapy to improve lung sparing in treatment planning for distal esophageal cancer.

BACKGROUND AND PURPOSE: To evaluate the feasibility whether intensity-modulated radiotherapy (IMRT) can be used to reduce doses to normal lung than three-dimensional conformal radiotherapy (3 DCRT) in treating distal esophageal malignancies. PATIENTS AND METHODS: Ten patient cases with cancer of the distal esophagus were selected for a retrospective treatment-planning study. IMRT plans using four, seven, and nine beams (4B, 7B, and 9B) were developed for each patient and compared with the 3 DCRT plan used clinically. IMRT and 3 DCRT plans were evaluated with respect to PTV coverage and dose-volumes to irradiated normal structures, with statistical comparison made between the two types of plans using the Wilcoxon matched-pair signed-rank test. RESULTS: IMRT plans (4B, 7B, 9B) reduced total lung volume treated above 10 Gy (V(10)), 20 Gy (V(20)), mean lung dose (MLD), biological effective volume (V(eff)), and lung integral dose (P<0.05). The median absolute improvement with IMRT over 3DCRT was approximately 10% for V(10), 5% for V(20), and 2.5 Gy for MLD. IMRT improved the PTV heterogeneity (P<0.05), yet conformity was better with 7B-9B IMRT plans. No clinically meaningful differences were observed with respect to the irradiated volumes of spinal cord, heart, liver, or total body integral doses. CONCLUSIONS: Dose-volume of exposed normal lung can be reduced with IMRT, though clinical investigations are warranted to assess IMRT treatment outcome of esophagus cancers.

Dose-Response Relationship, Radiation↗

Intensity-modulated radiation therapy for mesothelioma: impact of multileaf collimator leaf width and pencil beam size on planning quality and delivery efficiency.

PURPOSE: To compare treatment plans for multileaf collimators (MLCs) with different leaf widths and different finite pencil beam (FPB) sizes, to determine the planning quality and delivery efficiency of segmented MLC (SMLC) delivery of intensity-modulated radiation therapy (IMRT) for malignant pleural mesothelioma (MPM). METHODS AND MATERIALS: Computerized tomography images of 10 right-side MPM patients were used for this planning study on a CORVUS treatment-planning system (NOMOS Corporation, Sewickley, PA) for a Varian Millennium 120-MLC (Varian Medical Systems, Palo Alto, CA). Three beam models were used. The first model forced two 0.5-cm MLC leaves to move in tandem to simulate a 1-cm leaf-width MLC and a FPB size of 1 x 1 cm2. The second model used 0.5-cm leaves with a FPB size of 0.5 x 1 cm2 (1 cm in the direction of leaf movement). The third model used 0.5-cm leaves, with a FPB size of 0.5 x 0.5 cm2. For optimization, the same dose constraints and beam parameters were used for each data set. Tissue heterogeneity corrections were used during optimization and dose calculation. Plans were optimized such that the clinical target volume received 50 Gy in 25 fractions. Dose distributions to the target and normal structures were evaluated. The number of monitor units, the number of segments, and delivery times were used to evaluate delivery efficiency. RESULTS: All three beam models could be used for IMRT planning for MPM. The doses to clinical target volume, spinal cord, lung, liver, heart, and contralateral kidney were acceptable with all three beam models. The 0.5 x 0.5-cm2 beam model used the most monitor units (6883 +/- 974 vs. 3332 +/- 406 and 3407 +/- 443 for the 1 x 1-cm2 and 0.5 x 1-cm2 models, respectively) and treated the most segments (4297 +/- 802 vs. 1357 +/- 156 and 1767 +/- 212 for the 1 x 1-cm2 and 0.5 x 1-cm2 models, respectively). The plan generated with the 1 x 1-cm2 model required the least amount of time to deliver. CONCLUSIONS: The quality of the MPM IMRT plans generated with the three beam models presented here was similar; however, the 1 x 1-cm2 model provided the most efficient delivery of MPM IMRT with the CORVUS planning system.

Aged↗

Interactively exploring optimized treatment plans.

PURPOSE: A new paradigm for treatment planning is proposed that embodies the concept of interactively exploring the space of optimized plans. In this approach, treatment planning ignores the details of individual plans and instead presents the physician with clinical summaries of sets of solutions to well-defined clinical goals in which every solution has been optimized in advance by computer algorithms. METHODS AND MATERIALS: Before interactive planning, sets of optimized plans are created for a variety of treatment delivery options and critical structure dose-volume constraints. Then, the dose-volume parameters of the optimized plans are fit to linear functions. These linear functions are used to show in real time how the target dose-volume histogram (DVH) changes as the DVHs of the critical structures are changed interactively. A bitmap of the space of optimized plans is used to restrict the feasible solutions. The physician selects the critical structure dose-volume constraints that give the desired dose to the planning target volume (PTV) and then those constraints are used to create the corresponding optimized plan. RESULTS: The method is demonstrated using prototype software, Treatment Plan Explorer (TPEx), and a clinical example of a patient with a tumor in the right lung. For this example, the delivery options included 4 open beams, 12 open beams, 4 wedged beams, and 12 wedged beams. Beam directions and relative weights were optimized for a range of critical structure dose-volume constraints for the lungs and esophagus. Cord dose was restricted to 45 Gy. Using the interactive interface, the physician explored how the tumor dose changed as critical structure dose-volume constraints were tightened or relaxed and selected the best compromise for each delivery option. The corresponding treatment plans were calculated and compared with the linear parameterization presented to the physician in TPEx. The linear fits were best for the maximum PTV dose and worst for the minimum PTV dose. Based on the root-mean-square error between the fit values and their corresponding data values, the linear fit appears to be adequate, although higher order polynomials could give better results. Some of the variance in fit is due to the stochastic nature of the simulated annealing optimization algorithm, which does not reproduce the exact same results in repetitions of the same calculation. Using a directed search algorithm for plan optimization should produce better parameter fits and, therefore, better predictions of plan characteristics by TPEx. CONCLUSIONS: Using TPEx, the physician can easily select the optimum plan for a patient, with no imposed arbitrary definition of the "best" plan. More importantly, the physician can readily see what can be achieved for the patient with a given delivery technique. There is no more uncertainty about whether or not a better plan exists. By comparing the "best" plans for different delivery options (e.g., three-dimensional conformal radiotherapy versus intensity-modulated radiation therapy), the physician can gauge the clinical benefits of greater technical complexity. However, before the TPEx process can be clinical useful, faster computers and/or algorithms are needed and more studies are needed to better model the spaces of optimized solutions.

Algorithms↗

Intensity modulated radiation therapy and proton radiotherapy for non-small cell lung cancer.

Local failure of non-small-cell lung cancer (NSCLC) radiotherapy may cause continuous tumor seeding and death. Radiotherapy dose escalation has been shown to improve local control and survival. However, the toxicities associated with dose escalation are significant and limit the potential of dose escalation. Intensity modulated radiotherapy (IMRT) may have the potential to improve the therapeutic ratio for photon treatment of lung cancer by sparing surrounding normal tissues. However, low-dose exposure to normal lung and organ motion is a major concern. We have conducted several studies to address these issues and started clinical studies to evaluate the potential benefit of IMRT in patients with NSCLC. Proton radiotherapy may have greater potential to spare normal tissue and allow for further dose escalation and acceleration. We are conducting preclinical and clinical studies for imaging-guided proton radiotherapy in NSCLC. In this paper, we discuss the preliminary data, IMRT treatment guidelines, and ongoing studies for proton therapy in NSCLC.

Carcinoma, Non-Small-Cell Lung↗

Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from varian clinac 2100 series linear accelerators.

The current study presents the reference photon dosimetry data (RPDD) and reference phase space data (RPSD) for the 6 MV photon beam from Varian 2100 series linear accelerators. The RPDD provide the basic photon dosimetry data, typically collected during the initial commissioning of a new linear accelerator, including output factors, depth dose data, and beam profile data in air and in water. The RPSD provide the full phase space information, such as position, direction, and energy for each particle generated inside the head of any particular linear accelerator in question. The dosimetric characteristics if the 6 MV photon beam from the majority of the aforementioned accelerators, which are unaltered from the manufacturer's original specifications, can be fully described with these two data sets within a clinically acceptable uncertainty (approximately +/-2 %). The current study also presents a detailed procedure to establish the RPDD and RPSD using measured data and Monte Carlo calculations. The RPDD were constructed by compiling our own measured data and the average data based on the analysis of more than 50 sets of measured data from the Radiological Physics Center (RPC) and 10 sets of clinical dosimetry data obtained from 10 different institutions participating in the RPC's quality assurance monitoring program. All the measured data from the RPC and the RPC-monitored institutions were found to be within a statistically tight range (i.e., 1sigma approximately 1% or less) for each dosimetric quantity. The manufacturer's standard data, except for in-air off-axis factors that are available only from the current study, were compared with the RPDD, showing that the manufacturer's standard data could also be used as the RPDD for the photon beam studied in this study. The RPSD were obtained from Monte Carlo calculations using the BEAMnrc/ DOSXYZnrc code system with 6.2 MeV (a spread of 3% full width at half maximum) and 1.0 mm full width at half maximum as the values of the energy and radial spread of a Gaussian electron pencil beam incident on the target, respectively. The RPSD were capable of generating Monte Carlo data that agreed with the RPDD within the acceptance criteria adopted in the current study (e.g., 1% or 1 mm for depth dose). A complete set of the RPDD and RPSD from the current study is available from the RPC website (http://rpc.mdanderson.org) or via mass storage media such as DVD or CD-ROM upon request.

Electrons↗

Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.

Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory.

Computer Simulation↗

Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part II-margin reduction of internal target volume.

PURPOSE: To analyze the relationship between lung motion and skin surface motion during respiration, determine the uncertainties and variability of such a relationship, and assess the potential of reducing internal target margin for gated radiotherapy. METHODS AND MATERIALS: Three healthy volunteers and four lung cancer patients were recruited in a prospective imaging study using MRI to track the internal lung and external skin motion during breathing. The relationship between the lung and skin motion was modeled using linear regression analysis. The slope of the linear fit and its confidence interval were analyzed for different lung locations, skin surface locations, and breathing patterns from separate imaging sessions. The margins of the internal target volume were calculated based on the residual lung motion during gating and its uncertainties from multiple treatment fractions for the gated treatment. RESULTS: The slope and confidence interval of the linear regression from the motion analysis were uniquely defined by the locations of the lung, skin surface, and breathing patterns. Statistically significant differences were observed among individuals and between different times of measurement. The normal free-breathing motion averaged from all volunteer and patient data was 13.4 +/- 7.4 mm along the superior-inferior (SI) direction and 6.9 +/- 2.6 mm along the anterior-posterior (AP) direction. With simulated respiratory gating, the average margin reduction was 5.5 +/- 4.8 mm and 1.6 +/- 1.0 mm, respectively, along the SI and AP directions (or 36% +/- 15% and 25% +/- 14%, respectively, relative to free-breathing motion). CONCLUSION: Because respiratory movement is rather complex, the relationship between the lung and skin surface motion is affected by many anatomic and physiologic factors. The reduction of internal target margin and efficacy of the free-breathing gating technique should be assessed for individual cases.

Adult↗

Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I--correlating internal lung motion with skin fiducial motion.

PURPOSE: To measure the internal lung motion due to respiration using magnetic resonance images (MRIs); to evaluate the correlation between lung motion and skin surface motion and the reliability of tracking lung motion with external fiducials. METHODS AND MATERIALS: An MRI protocol using fast gradient-echo sequences was developed to acquire dynamic cine images of the thoracoabdominal region along the axial, sagittal, and coronal planes. The subjects (3 healthy volunteers and 4 lung cancer patients) were instructed to perform normal or altered breathing during MRI. Lung vessels identified on MRI were used as anatomic landmarks for internal lung structures. From sagittal cine MRI scans, the positions of the lung vessels and skin surface were tracked and their movements measured. Correlation between the movements of the external markers and internal structures was then calculated and analyzed. RESULTS: Lung vessel motion in the superior-inferior (SI) direction correlated best with mid-upper abdominal skin surface movement (correlation coefficient, 0.89 +/- 0.09 and 0.87 +/- 0.23 for volunteers and patients, respectively). The anterior-posterior (AP) vessel motion generally correlated poorly with the skin surface movement, with marker placement on the upper chest yielding the strongest results (correlation coefficient, 0.72 +/- 0.23 and 0.44 +/- 0.27 for volunteers and patients, respectively). The strength of the correlation depended on the locations of the tracked vessels, locations of the skin surface, and subjects' breathing patterns. The best correlation was seen between the motion of an abdominal fiducial and SI lung motion. Significant intersubject variability was also observed. CONCLUSION: Movement of an external fiducial may not correlate fully with, or predict, internal lung motion. Effective monitoring of respiration may have to rely on a combination of multiple fiducials and other physiologic parameters, such as lung volume and/or air flow.

Adult↗

Comparison of rectal dose-wall histogram versus dose-volume histogram for modeling the incidence of late rectal bleeding after radiotherapy.

PURPOSE: To compare the fits of normal-tissue complication probability (NTCP) models based on rectal dose-wall histograms (DWHs) vs. dose-volume histograms (DVHs) when the two are used to analyze a common set of late rectal toxicity data. METHODS AND MATERIALS: Data were analyzed from 128 prostate cancer patients treated with 3-dimensional conformal radiotherapy (3D-CRT) at The University of Texas M.D. Anderson Cancer Center (UTMDACC). The DVH for total rectal volume, including contents, was obtained for each patient from the treatment-planning system. A DWH was also computed, using the outer rectal contour plus an autogenerated inner contour that corresponds to an assumed 3-mm rectal wall thickness. The endpoint for analysis was Grade 2 or higher late rectal bleeding within 2 years of treatment; all patients had at least 2 years of follow-up. Four different NTCP models were fitted to the response data by using either the DVH or the DWH to describe the dose distribution to rectum or rectal wall, respectively. The 4 models considered were the Lyman model, the mean dose model, the parallel-architecture model, and a model based on the volume of a organ receiving more than a specified dose (the "cutoff-dose" model). RESULTS: For each of the models, the fit to the late rectal bleeding data was slightly improved when the analysis was based on the rectal DWH instead of on the DVH. In addition, the results of the cutoff dose and parallel architecture models were consistent with one another for the DWH data but not for the DVH data. For the DWH data, both models predict a 50% or higher incidence of Grade 2 or worse late rectal bleeding within 2 years if 80% or more of the rectal wall is exposed to doses greater than 32 Gy. A 50% or higher incidence of rectal bleeding is also predicted if the mean dose to rectal wall exceeds 53.2 Gy. CONCLUSIONS: A consistent, although modest, improvement occurs in the fits of NTCP models to the UTMDACC 2-year late rectal bleeding data when the fit is based on the rectal dose-wall histogram instead of on the dose-volume histogram for entire rectum, including contents.

Confidence Intervals↗

Cluster models of dose-volume effects.

PURPOSE: Describe cluster models, normal-tissue complication probability models in which both the number and the spatial location of radiation-sterilized functional subunits play a role in defining complication probability. METHODS AND MATERIALS: Computer simulation was used to determine the maximum size cluster of sterilized subunits associated with a given dose distribution. Complications were associated with large clusters. RESULTS: Cluster models showed a volume effect, as increasing effect for constant dose when the volume increased or constant effect when the dose was reduced with increasing volume. Cluster models gave similar results to existing models when tissues were irradiated uniformly. With inhomogeneous dose distributions, on the other hand, different spatial distributions of "hot spots" may lead to different predictions of complication probability by cluster models. The result was that a higher complication probability resulted when hot spots were contiguous (clustered) than when they were dispersed, even if both situations are characterized by the same dose-volume histogram. A potential advantage of cluster models is to provide an easy, internally consistent way to predict complications arising from the inhomogeneous dose distributions that sometimes arise with intensity-modulated radiotherapy. CONCLUSION: Cluster models offer a new way to quantify complication probability in treatment situations in which a wide variety of hot-spot distributions occur.

Animals↗

Dose-volume response analyses of late rectal bleeding after radiotherapy for prostate cancer.

PURPOSE: To compare the fits of various normal tissue complication probability (NTCP) models to a common set of late rectal toxicity data, with the aim of identifying the best model for predicting late rectal injury after irradiation. METHODS AND MATERIALS: Late toxicity data from 128 prostate cancer patients treated on protocol with three-dimensional conformal radiotherapy at The University of Texas M.D. Anderson Cancer Center (UTMDACC) were analyzed. The dose-volume histogram for total rectal volume, including contents, was obtained for each patient, and the presence or absence of Grade 2 or worse rectal bleeding within 2 years of treatment was scored. Five different NTCP models were fitted to the data using maximum likelihood analysis: the Lyman model, the mean dose model, a parallel architecture model, and models based on either a cutoff dose or a cutoff volume. RESULTS: All five of the NTCP models considered provided very similar fits to the UTMDACC rectal bleeding data. In particular, none of the more highly parameterized models (the four-parameter parallel model, three-parameter Lyman model, or three-parameter cutoff dose and volume models) provided a better fit than the simplest of the models, the two-parameter NTCP model describing rectal bleeding as a probit function of mean dose to rectum. CONCLUSION: No dose-volume response model has yet been identified that provides a better description of the UTMDACC rectal toxicity data than the mean dose model. Because this model has relatively low predictive accuracy, the need to identify a better model remains.

Dose-Response Relationship, Radiation↗

Feasibility of sparing lung and other thoracic structures with intensity-modulated radiotherapy for non-small-cell lung cancer.

PURPOSE: To investigate the possibility of using intensity-modulated radiotherapy (IMRT) to reduce the irradiated volumes of the normal lung and other critical structures in the treatment of non-small-cell lung cancer (NSCLC) and to investigate the effect of IMRT on the potential of spreading low doses to large volumes of normal tissues in such treatment. METHODS AND MATERIALS: A retrospective treatment planning study was performed to compare IMRT and conventional three-dimensional conformal radiation therapy (3D-CRT) for 10 NSCLC patients (Stage I-IIIB). In the IMRT plans, three to nine coplanar beams were designed to treat 95% of the planning target volume with 63 Gy and to minimize the volumes of the normal lung, esophagus, heart, and spinal cord irradiated above their tolerance doses. The two types of plans were compared with respect to the planning target volume coverage, dose-volume histograms, and other dosimetric indexes of the normal structures. RESULTS: Comparing the nine-beam IMRT plan with the 3D-CRT plan, the percentage of lung volume that received >20 Gy and the mean lung dose were reduced for all cases, with a median reduction of 8% and 2 Gy, respectively. An additional reduction of the >5-Gy volume and >10-Gy volume for the lung and thoracic tissue was more difficult with IMRT, although still possible using fewer beams in IMRT. The integral dose to the entire thorax was equivalent and even reduced for 8 of 10 cases using IMRT. CONCLUSION: It is possible to reduce the volumes of low doses (such as the >10-Gy volume and >20-Gy volume) for thoracic normal tissues using IMRT. The increased integral dose and low-dose volumes can be avoided for IMRT if such concerns are addressed carefully in the inverse planning process and with optimization of the IMRT beam configuration.

Carcinoma, Non-Small-Cell Lung↗

Dose and volume reduction for normal lung using intensity-modulated radiotherapy for advanced-stage non-small-cell lung cancer.

PURPOSE: To investigate dosimetric improvements with respect to tumor-dose conformity and normal tissue sparing using intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3D-CRT) for advanced-stage non-small-cell lung cancer (NSCLC). METHODS AND MATERIALS: Forty-one patients with Stage III-IV and recurrent NSCLC who previously underwent 3D-CRT were included. IMRT plans were designed to deliver 63 Gy to 95% of the planning target volume using nine equidistant coplanar 6-MV beams. Inverse planning was performed to minimize the volumes of normal lung, heart, esophagus, and spinal cord irradiated above their tolerance doses. Dose distributions and dosimetric indexes for the tumors and critical structures in both plans were computed and compared. RESULTS: Using IMRT, the median absolute reduction in the percentage of lung volume irradiated to >10 and >20 Gy was 7% and 10%, respectively. This corresponded to a decrease of >2 Gy in the total lung mean dose and of 10% in the risk of radiation pneumonitis. The volumes of the heart and esophagus irradiated to >40-50 Gy and normal thoracic tissue volume irradiated to >10-40 Gy were reduced using the IMRT plans. A marginal increase occurred in the spinal cord maximal dose and lung volume >5 Gy in the IMRT plans, which could be have resulted from the significant increase in monitor units and thus leakage dose in IMRT. CONCLUSION: IMRT planning significantly improved target coverage and reduced the volume of normal lung irradiated above low doses. The spread of low doses to normal tissues can be controlled in IMRT with appropriately selected planning parameters. The dosimetric benefits of IMRT for advanced-stage non-small-cell lung cancer must be evaluated further in clinical trials.

Adult↗

Dosimetric benefits of respiratory gating: a preliminary study.

In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased. Computed tomography (CT) image data sets were acquired for 10 patients who had been diagnosed with primary bronchogenic carcinoma. Data sets were acquired during free breathing and during breath-holds at 0% tidal volume and 100% tidal volume, and, when possible, at deep inspiration, corresponding to approximately 60% vital capacity. Two treatment plans were developed on the basis of each of the gated data sets: one in which the treatment portals were those of the free-breathing plan, and the other in which the treatment portals were based on the gated planning target volumes. Dose-mass histograms of the lungs calculated at 0% tidal volume were compared to those calculated at deep inspiration and at 100% tidal volume. Data extracted from the dose-mass histograms were used to determine the most dosimetrically beneficial point to gate, the reduction in the amount of irradiated lung tissue that resulted from gating, and any disease characteristics that might predict a greater need for gating. The data showed a reduction in the mass of normal tissue irradiated when treatment portals based on the gated planning target volume were used. More normal lung tissue was spared at deep inspiration than at the other two gating points for all patients, but normal lung tissue was spared at every point in the respiratory cycle. No significant differences in the amount of irradiated tissue by disease characteristic were identified. Respiratory gating of thoracic radiation treatments can often improve the quality of the treatment plan, but it may not be possible to determine which patients may benefit from gating prior to performing the actual treatment planning.

Artifacts↗

Verification of the accuracy of a photon dose-calculation algorithm.

An extensive set of measured data was developed for the purpose of verifying the accuracy of a photon dose-calculation algorithm. Dose distributions from a linear accelerator were measured using an ion chamber in a water phantom and thermoluminescent dosimeters in a heterogeneous anthropomorphic phantom. Test cases included square fields, rectangular fields, fields having different source-to-surface distances, wedged fields, irregular fields, obliquely incident fields, asymmetrically collimated fields with wedges, multileaf collimator-shaped fields, and two heterogeneous density cases. The data set was used to validate the photon dose-calculation algorithm in a commercial radiation treatment planning system. The treatment planning system calculated photon doses to within the American Association of Physicists in Medicine (AAPM) Task Group 53 (TG-53) criteria for 99% of points in the buildup region, 90% of points in the inner region, 88% of points in the outer region, and 93% of points in the penumbra. For the heterogeneous phantoms, calculations agreed with actual measurements to within +/-3%. The monitor unit tests revealed that the 18-MV open square fields, oblique incidence, oblique incidence with wedge, and mantle field test cases did not meet the TG-53 criteria but were within +/-2.5% of measurements. It was concluded that (i) the photon dose calculation algorithm used by the treatment planning system did not meet the TG-53 criteria 100% of the time; (ii) some of the TG-53 criteria may need to be modified, and (iii) the generally stated goal of accuracy in dose delivery of within 5% cannot be met in all situations using this beam model in the treatment planning system.

Algorithms↗

PTV margin determination in conformal SRT of intracranial lesions.

The planning target volume (PTV) includes the clinical target volume (CTV) to be irradiated and a margin to account for uncertainties in the treatment process. Uncertainties in miniature multileaf collimator (mMLC) leaf positioning, CT scanner spatial localization, CT-MRI image fusion spatial localization, and Gill-Thomas-Cosman (GTC) relocatable head frame repositioning were quantified for the purpose of determining a minimum PTV margin that still delivers a satisfactory CTV dose. The measured uncertainties were then incorporated into a simple Monte Carlo calculation for evaluation of various margin and fraction combinations. Satisfactory CTV dosimetric criteria were selected to be a minimum CTV dose of 95% of the PTV dose and at least 95% of the CTV receiving 100% of the PTV dose. The measured uncertainties were assumed to be Gaussian distributions. Systematic errors were added linearly and random errors were added in quadrature assuming no correlation to arrive at the total combined error. The Monte Carlo simulation written for this work examined the distribution of cumulative dose volume histograms for a large patient population using various margin and fraction combinations to determine the smallest margin required to meet the established criteria. The program examined 5 and 30 fraction treatments, since those are the only fractionation schemes currently used at our institution. The fractionation schemes were evaluated using no margin, a margin of just the systematic component of the total uncertainty, and a margin of the systematic component plus one standard deviation of the total uncertainty. It was concluded that (i) a margin of the systematic error plus one standard deviation of the total uncertainty is the smallest PTV margin necessary to achieve the established CTV dose criteria, and (ii) it is necessary to determine the uncertainties introduced by the specific equipment and procedures used at each institution since the uncertainties may vary among locations.

Brain Neoplasms↗