Elective Wiktor GX stenting for symptomatic stenosis in old aortocoronary saphenous vein bypass grafts: the Antwerp experience.

PURPOSE: We compared initial outcome, peri-procedural complications and long-term clinical follow-up of elective Wiktor GX stent implantation in severely narrowed vein grafts to a historic register of elective angioplasties in saphenous vein grafts in the same center. METHODS: Eighty-one consecutive patients with angina and a history of coronary artery bypass grafting (CABG), all received elective angioplasty (PTCA) of the diseased graft; we described them as group P. The next 38 consecutive patients were treated with elective angioplasty and Wiktor Stent implantation, followed by one month ticlopidine; they were called group S. CONCLUSION: This retrospective study suggests that elective Wiktor stenting in old saphenous vein graft stenosis, in combination with one month ticlopidine, leads to: 1) a better angiographic result, with reduction of peri-procedural complications; and 2) a lower incidence of recurrent angina, need for invasive or surgical re-intervention, myocardial infarction and death during follow-up.

Aged↗

Cardiac graft vasculopathy: aetiologic factors and therapeutic approaches.

Heart transplantation has become an accepted and successful treatment for end-stage heart disease with survival rates of 80-90% after one year and 70% after 5 years. During the early posttransplant period (6-12 months), patients are subject to two major complications: rejection and infection. Fortunately, a certain degree of graft tolerance develops, allowing the immunosuppressive therapy to be progressively tapered off with a concomitant decrease in infectious problems. Long-term survival, however, is largely dependent on the development of an accelerated atherosclerosis in the graft, which is believed to represent some kind of chronic rejection. This transplant vasculopathy is documented by means of coronary angiography with an incidence of approximately 5 to 10% per year. It is not surprising therefore that major interest has risen concerning risk factors promoting this pathology.

Graft Occlusion, Vascular↗

External vibration interference of activity based rate responsive pacemakers.

The change of the pacing rate in response to external vibration interference was assessed in four rate responsive pacemakers with a piezoelectric crystal (Medtronic Activitrax 8403, Siemens Sensolog 3, Biotronik Ergos 01, and Medtronic Legend 8417) and one with an accelerometer (CPI Excel VR 1119). They were tested in the laboratory. External vibration was simulated in vitro by exposing the different pacemakers to a controlled sinusoidal vibration force generated by a Millar pressure vibration amplifier type MGM-30 (Millar Instruments, Inc., Houston, TX, USA). All pacemakers were programmed at standard settings. Two types of vibration forces were applied: (1) one with varying amplitude but with constant vibration frequency; and (2) one with varying frequency but with constant vibration amplitude. In this manner curves of pacing rate versus vibration forces versus vibration frequency were obtained. High vibration forces and low vibration frequencies were associated with the highest pacing rate response. In this experimental setting, the pacemaker based on the accelerometer principle apparently was the least sensitive to high frequency vibrations, which are known to be related to environmental interference. It also seemed more appropriately responsive in the lower frequency range, which is more appropriate for the detection of true physiological activity.

Acceleration↗

[P wave changes and atrial fibrillation after implantation of VVI type pacemaker].

The P waves of patients with VVI pacemakers were compared with those of DDD pacemakers at implantation and then regularly for 5 years. A certain number of cardiac pathologies are known to cause P wave changes. The incidence of atrial fibrillation (AF) was much higher in VVI than in DDD patients. In the VVI group, the incidence was much greater in patients paced for sinus node disease than in patients paced for AVB. Analysis of sinus P wave characteristics in 320 patients with VVI pacemakers shows progressive abnormalities of atrial function with time. The expression of this atrial dysfunction is a statistically significant prolongation of the P wave in V1 and dII and of the terminal part of the P wave in V1. The factors responsible for this abnormality and which favours the occurrence of AF are quasi-permanent pacing, the presence of retrograde conduction and an abnormality of atrial activation at the time of implantation.

Aged↗

Evolution of P wave characteristics after pacemaker implantation.

This study is an investigation of the long-term effects of VVI pacing on the atrium as derived from the evolution of P wave characteristics of 285 patients. The occurrence of left and right atrial disease is demonstrated as well as the evolution of left atrial hypertrophy in some cases. A comparison is made with DDD pacing and special attention is given to the progression to atrial fibrillation.