PubMed Health⌕ Search

Biomedical subjects

H Ihlen

Publications and source records attributed to H Ihlen.

At least 37 records · Page 2Linked to original sources

Increased risk of heart valve regurgitation after mediastinal radiation for Hodgkin's disease: an echocardiographic study.

OBJECTIVE: To assess by echocardiography the occurrence and degree of late cardiac sequelae after treatment for Hodgkin's disease by radiation and chemotherapy. PATIENTS AND METHODS: In Norway from 1980 to 1988, 129 patients < 50 years old with Hodgkin's disease had curative treatment with mediastinal radiation, with or without chemotherapy. 116 (90%) of these patients (mean (SD) age 37 (7) years, 67 males) were examined by echocardiography 5-13 years after treatment. 40 healthy individuals (mean (SD) age 40 (11), 20 males) were examined as controls. All those examined were in regular sinus rhythm. RESULTS: Grade > 1 (scale 0-3) aortic and/or mitral valvar regurgitation was found in 24% of the patients (15% aortic, 7% mitral, and 2% aortic+mitral), affecting 46% of the females v 16% of the males (P < 0.001). Female gender was a significant risk factor for aortic and mitral regurgitation (odds ratio 4.7, 95% confidence interval 2.0 to 11.2), whereas age, period of follow up, radiation dose, and chemotherapy were not. Thickened pericardium was diagnosed in 15% of the patients. No risk factors were identified. No cases of pericardial thickening or valvar regurgitation grade > 1 were recorded in the control group. Mean values for measured and calculated indices of systolic and diastolic function were within the normal range for patients and controls. The patients had reduced E/A ratio compared with the healthy controls (E/A 1.1 v 2.0, P < 0.001). CONCLUSIONS: Abnormal left sided valvar regurgitation was detected in one fourth of the patients, affecting the aortic valve in more than half of the cases. Females had an increased risk of valvar regurgitation. Echocardiographic screening after high-dose mediastinal radiation is recommended.

Adult↗

[Hypercholesterolemia--a clinical problem in heart transplantation. A therapeutic trial with low-dose lovastatin].

One year after heart transplantation, serum total cholesterol had increased by 24% in 103 recipients on prednisolon, cyclosporin A, and azathioprin immuno-suppression, and was above 5.2 mmol/l in 84 of them. Incremental small dose lovastatin treatment up to 20 mg per day safely reduced total cholesterol by 19% and LDL-cholesterol by 24% in 14 patients with serum cholesterol above 7.5 mmol/l. Serum concentration of lovastatin did not increase further after three weeks treatment with 20 mg. It is concluded that hypercholesterolaemia in heart recipients treated with cyclosporin A can be treated safely with small dose lovastatin. Drug therapy should be individualized and conducted by physicians experienced in transplantation medicine.

Adult↗

A new color M-mode index of diastolic filling compared with radionuclide ventriculography.

We correlated the new diastolic index 'delay of apical peak velocity', as measured by colour M-mode Doppler, with radionuclide ventriculographic indices of ventricular function. Thirty-seven patients with coronary artery disease participated in the prospective and blinded study, which included repeated acquisitions to determine the effect of realigning the Doppler sample beam. In multiple regression, neither peak filling rate, left ventricular phase histogram width nor ejection fraction were statistically significantly related to delay of apical peak velocity. The standard deviation of the differences between duplicate colour M-mode acquisitions corresponded to half the reference range of the index. We conclude that in this blinded investigation, the new Doppler index did not provide information about ventricular function equivalent to radionuclide ventriculography. The index may be significantly influenced by sample beam position.

Aged↗

Visual assessment of intra ventricular flow from colour M-mode Doppler images.

Left intra ventricular filling was studied by colour M-mode Doppler ultrasound to determine whether the flow pattern can be assessed visually, and explore its relation to left ventricular (LV) function. Patients with coronary artery disease (CAD) or dilated cardiomyopathy (DCM) were divided into three groups according to angiographically evaluated LV function. The groups were compared with a control group of 54 healthy volunteers. The mitral to apical delay of early diastolic flow was qualitatively assessed from printed colour M-mode images, twice by four independent observers blinded to the subject's status. The repeatability of the assessments as determined by the kappa statistic was good intra observer (kappa = 0.75) and moderate inter observer (kappa = 0.53). The CAD-group with angiographically normal LV function (n = 25) had flow patterns resembling those observed in the control group. The group with ejection fraction (EF) < 50% (n = 19) had flow patterns clearly different from the control group. Patients with regional wall motion abnormality (RWMA) but EF > 50% (n = 16) exhibited flow patterns intermediate between the control and the low EF group. Among the 50 CAD patients there was a negative correlation between EF and the presence of delay of apical peak velocity (Spearman's rs = -0.62, p < 0.0001). A visible delay of apical peak velocity had a sensitivity towards DCM of 83% and specificity of 75%. The sensitivity towards CAD with either RWMA or low EF was 55% and the specificity 75%. In conclusion, visual assessment of intra ventricular flow patterns was feasible and allowed discrimination between normal and diseased ventricles.

Adult↗

Repeatability of colour M-mode Doppler measurements of left ventricular filling.

We investigated the repeatability of two recently reported colour M-mode Doppler measures of left ventricular diastolic function. 'Delay of peak velocity' is the time interval from peak velocity of early filling at the mitral tip level to peak velocity in the apical region. The 'velocity of flow propagation' is the speed of the mitral to apical spread of the early diastolic filling. Two examiners independently and blindly made measurements by both methods on 32 digital recordings twice, using custom software. Inter- and intra-observer repeatability were given in terms of limits of agreement, where 1 denotes perfect agreement. Limits of intra-observer agreement were 0.72-1.43 for measurements of 'delay of peak velocity', and 0.39-2.28 for 'velocity of flow propagation'. Limits of inter-observer agreement were 0.68-1.42 and 0.19-2.04 respectively. The correlation between the methods was weak (r = 0.45), suggesting that they may detect different properties of early diastole. We suggest that the reliability of the methods may be improved by replicate measurements performed blindly. There are reasons to express the velocity of flow propagation on a logarithmic scale.

Echocardiography, Doppler↗

Repeatability of measurements of pulmonary venous flow indices.

We investigated the measurement repeatability of four pulmonary venous flow indices. The indices were measured on 45 anonymised, transthoracic Doppler recordings of adequate technical quality. Measurements were taken by two independent observers, and repeated after 10 days. Plus/minus the repeatability coefficient, which was used to quantify repeatability, gives the 95% probability limits for random variation between repeated measurements. The index D-diff, which is the difference in duration of the pulmonary venous flow reversal during atrial systole and the transmitral A-wave, had repeatability coefficients of 50 and 57 ms intra- and inter-observer. For the fraction of antegrade pulmonary venous flow during ventricular systole, the coefficients were 12 and 13 percentage points, but improved to 6 and 7 among the high-quality recordings. The retrograde pulmonary venous flow during atrial systole as a fraction of the antegrade flow, had coefficients of 5 percentage points both intra- and inter-observer. The coefficient for the peak velocity of retrograde pulmonary venous flow was 0.05 m/s intra- and inter-observer. Thus, the systolic fraction was the only index that showed a satisfactory repeatability. We suggest that if the other indices are used, measurements should be taken by a blinded observer to avoid observer bias.

Analysis of Variance↗

Intracavitary filling pattern in the failing left ventricle assessed by color M-mode Doppler echocardiography.

OBJECTIVES: The present study aimed to investigate the mechanism of intracavitary changes in filling pattern during acute ischemic left ventricular failure and during beta-adrenergic blockade. BACKGROUND: Recent clinical studies with color M-mode Doppler imaging have shown abnormal intracavitary filling patterns in the diseased ventricle. METHODS: In open chest anesthetized dogs with intracardiac micromanometers and myocardial segment-length crystals, global ischemic left ventricular failure was induced (n = 8) by coronary microembolization. In nonischemic ventricles inotropy was decreased (n = 6) by intravenous propranolol and increased (n = 6) by intravenous isoproterenol. From color M-mode Doppler images we calculated the time difference between peak early diastolic filling velocity at the mitral tip and apex using computer analysis. The time difference of peak velocity was used as an index of the timing of apical filling. RESULTS: There was marked retardation of apical filling with microembolization and propranolol. Time difference of peak velocity increased from 20 +/- 6 (mean +/- SEM) to 101 +/- 17 ms (p < 0.05) and from 21 +/- 8 to 80 +/- 18 ms (p < 0.05), respectively. Time constant of isovolumic relaxation increased from 34 +/- 3 to 43 +/- 5 ms (p < 0.05) and from 31 +/- 1 to 39 +/- 3 ms (p < 0.05) during microembolization and beta-blockade, respectively. Isoproterenol tended to cause the opposite changes. Time difference of peak velocity showed a positive correlation with time constant of isovolumic relaxation (r = 0.89, p < 0.01) and a negative correlation with peak early transmitral pressure gradient (r = 0.88, p < 0.01). In the intact left ventricle, peak apical filling velocity coincided with peak early transmitral pressure gradient. During ischemic failure however, peak apical filling velocity occurred 53 +/- 14 ms after peak early transmitral pressure gradient had decreased to zero and at a time when transmitral flow had ceased, suggesting a change in intraventricular flow distribution. CONCLUSIONS: Color M-mode Doppler imaging revealed retarded apical filling during depression of myocardial function by global myocardial ischemia or beta-blockade. The abnormal filling pattern may be a sign of impaired left ventricular relaxation.

Animals↗

Abnormalities of left ventricular filling in patients with coronary artery disease: assessment by colour M-mode Doppler technique.

In 54 healthy individuals and 107 patients with coronary artery disease, intraventricular early filling velocities were recorded by colour M-mode Doppler. The time difference between the occurrence of peak velocity in the apical region and at the mitral tip was calculated, and normalized by dividing it by the mitral to apical distance. Transmitral velocities were determined by the single pulsed Doppler technique. The patients were divided into groups according to systolic function as assessed by left ventriculography. The normalized time difference was similar in the reference group (12 +/- 8 ms.cm-1) and the patient group with no electrocardiographical signs of previous infarction and normal ventriculography (16 +/- 16 ms.cm-1). It increased significantly in the group with infarction and/or regional systolic dysfunction (43 +/- 21 ms.cm-1), and a further increase was present in the group with severely impaired ventricles (53 +/- 14 ms.cm-1). The ratio between peak early and late transmitral velocity fell significantly in the group with infarction and/or regional systolic dysfunction, but was normalized in the group with severely impaired ventricles. Colour M-mode Doppler shows that apical filling is delayed in patients with injured left ventricles due to coronary artery disease. This delay increases with progression of ventricular injury. The technique may be an important addition to transmitral pulsed Doppler in assessing left ventricular filling.

Adult↗

Intraventricular early diastolic filling during acute myocardial ischemia, assessment by multigated color m-mode Doppler echocardiography.

BACKGROUND: Color M-mode Doppler echocardiography has been suggested as a new noninvasive technique for assessing left ventricular diastolic function. The present study investigated intraventricular filling pattern by color M-mode Doppler in patients during percutaneous transluminal coronary angioplasty (PTCA). In a dog model of myocardial ischemia, the color M-mode flow pattern was related to indices of global and regional myocardial function. METHODS AND RESULTS: From color M-mode images, the time difference (TD) between occurrence of peak velocity in the apical region and at the mitral tip was determined in 20 patients and eight anesthetized dogs during coronary occlusions. During PTCA, the timing of peak velocity was progressively delayed from mitral valve to apex. Consistent with this, the dog model showed delayed apical filling during coronary occlusion; TD increased from 18 +/- 4 to 71 +/- 9 milliseconds (P < .01). In the ischemic region, systolic shortening (sonomicrometry) decreased from 20 +/- 3% to -5 +/- 2% (p < .01). The one-third filling fraction decreased from 59 +/- 5% to 31 +/- 6% (P < .01) and correlated with TD (r = .85, P < .01). The time constant of isovolumic relaxation (tau) increased slightly and correlated with TD (r = .81, P < .01). Pacing tachycardia, caval constriction, and volume loading were performed to mimic the ischemia-induced changes in heart rate, stroke volume, and intracavitary filling pressure, respectively. There were no significant changes in TD or tau during these interventions. CONCLUSIONS: Color M-mode Doppler echocardiography showed a marked delay of apical peak filling velocity during PTCA. The experimental data suggest that this reflects retarded filling of the ischemic ventricle. Thus, color M-mode Doppler may provide a useful method for assessing diastolic dysfunction.

Adult↗

Hemodynamic evaluation of the CarboMedics prosthetic heart valve in the aortic position: comparison of noninvasive and invasive techniques.

Seventy-three patients with a CarboMedics aortic bileaflet valve prosthesis were examined by Doppler ultrasonography, and 27 of them were also assessed by transseptal catheterization. The ultrasonic mean systolic gradient was 17.1 +/- 5.6 mm Hg for valve size 19 mm, falling gradually with increasing valve size to 6.8 +/- 2.5 mm Hg for size 27 mm. The catheter mean systolic gradient was consistently smaller than the ultrasonic gradient (4.3 +/- 4.8 mm Hg), but Tobit regression analysis showed a significant association between the two methods. In all patients both methods revealed negligible to small amounts of retrograde leakage, which is assumed to be a normal finding for this valve. The effective flow areas of the valves calculated from the ultrasonic data were similar to the in vitro calculated flow areas. The hemodynamic potential of this valve is therefore completely utilized in vivo. The effective orifice area corrected for body surface area increased with increasing valve size, which demonstrates a moderate valve-patient mismatch.

Adult↗

[Results of 6 1/2 years of heart transplantation at Rikshospitalet].

We discuss our experience from 6 1/2 years of orthotopic heart transplantation at Rikshospitalet (the National Hospital). 112 grafts were performed on 109 patients (19 women and 90 men), mean age 47 years (range 14-63). In the first nine patients the immunosuppressive regimen consisted of cyclosporine A and prednisolone, and in the last 100 azathioprine was added (triple medication). There was no operative mortality. 21 patients died, giving an 81% cumulative survival, with a significantly better prognosis among those who received triple immunosuppressive regimen. The main complications were rejection, infection and arrhythmia. Since our main problem was rejection it is concluded that careful supervision, concentrated on as few cardiologists as possible, and a liberal indication for myocardial biopsy, are decisive for the prognosis.

Adolescent↗

Reproducibility of echocardiographic estimates of the area of stenosed aortic valves using the continuity equation.

Interobserver variability in echocardiographic estimates of the area of stenosed aortic valves was assessed in 30 consecutive patients. Using the continuity equation, two independent observers calculated the area of stenosis from separate recordings of the diameter of the aortic orifice and the velocity time integral in the left ventricular outflow tract and in the stenotic jet. No significant difference between the observers was noted for any measurement. With respect to the area of stenosis, a high correlation between the observers was found (r = 0.92, P less than 0.001) and the regression line was close to the line of identity. The 95% limits of agreement were less than +/- 0.3 cm2. No discrepancy between the observers was found in the assessment of cases for aortic stenosis less than 0.8 cm2. Regression analyses showed good interobserver agreement also for the diameter of the orifice, the velocity time integrals, and the mean pressure gradient (r greater than 0.90, P less than 0.001). The greatest variability was noted for the diameter of the aortic orifice (95% limits of agreement +/- 1.4 cm2). We conclude that echocardiography enables reproducible estimates of the orificial area of stenosed aortic valves. Changes greater than 0.3 cm2 can be detected with a confidence probability of 95%. The greatest source of error is the measurement of the diameter of the outflow tract at the basal attachments of the aortic leaflets.

Adult↗

Cardiac output measured by Doppler echocardiography in patients with aortic prosthetic valves.

Quantification of blood flow is important for the correct interpretation of pressure gradients across prosthetic valves. Cardiac output was assessed simultaneously by Doppler echocardiography and the Fick oxygen method in 20 patients with aortic prosthetic valves. Velocity integral and diameter were measured in the outflow tract close to the valve at a site where the colour flow map showed no interference by valvular velocity. Doppler cardiac output was calculated by multiplying systolic velocity integral with area and heart rate. The variability of the haemodynamic parameters was tested in 10 additional patients. The non-invasive results correlated closely with the invasive results (r = 0.91, SEE 0.6 l min-1). Analysis of variance showed that no bias was introduced when cardiac output was determined by two different observers and on different days. Coefficient of variation for velocity integral, outflow area, heart rate and cardiac output were 9.6%, 7.2%, 6% and 10.8%, respectively. In conclusion, Doppler echocardiography is useful for estimating cardiac output in patients with aortic prosthetic valves.

Aortic Valve↗

Effects of beta-adrenergic blockade on left ventricular relaxation and filling dynamics in coronary artery disease: a pulsed Doppler echocardiographic study.

Left ventricular (LV) filling as assessed by Doppler transmitral flow velocity measurements was studied in 20 male patients with coronary artery disease (CAD) and in 18 normal individuals. Stroke volume, blood pressure and heart rate in the two groups were not significantly different. Compared to normals, the ratio between early and atrial-induced peak velocities was significantly lower in the patients (1.2 +/- 0.3 vs. 1.40 +/- 0.3, P = 0.01), as was the fraction of transmitral filling during the first 1/3 of diastole (45 +/- 7% vs. 50 +/- 4%, P less than 0.001). Isovolumic relaxation time (IV R) was 96 +/- 13 ms in patients vs. 74 +/- 12 ms in normals (P less than 0.001). The CAD patients were treated with atenolol for 13-24 days. The velocity ratio increased by 30% (P less than 0.001) due to a 12% increase in early (P = 0.004) and an 11% decrease in atrial-induced peak velocities (P = 0.01). Filling fraction and deceleration rate of early inflow both increased by 22% (P less than 0.001). IV R decreased by 8% (P = 0.01). After atenolol treatment, heart rate and blood pressure decreased by 23% and 10% (P less than 0.001), respectively, whereas stroke volume increased by 14% (P less than 0.001). Thus, CAD was associated with Doppler indices of retarded LV filling and myocardial relaxation. After atenolol treatment, significant increases in velocity ratio and filling fraction indicated a shift of filling from late towards early diastole, suggesting improved diastolic function. However, different factors related to beta-adrenergic blockade may have contributed to the observed changes.

Adrenergic beta-Antagonists↗