Spreeta-based biosensor assays for endocrine disruptors.

The construction and performance of an automated low-cost Spreeta-based prototype biosensor system for the detection of endocrine disrupting chemicals (EDCs) is described. The system consists primarily of a Spreeta miniature liquid sensor incorporated into an aluminum flow cell holder, dedicated to support a Biacore chip frame, in combination with a simple pressurized air-driven fluid system. During the optimization, a monoclonal antibody (MAb)-based immunoassay for the estrogenic compound bisphenol A (BPA) was used as a model. After the optimization two thyroxine transport protein inhibition assays for thyroid endocrine disruptors were implemented. The average noise of the system for 1 min of baseline was 1.1 microRIU (refractive index units) and it could be operated in the range of 18-22 degrees C with a minimum baseline drift (5-10 microRIU/100 min). Optimum signal to noise ratio (S/N R) was obtained using a flow cell height of 100 microm and a flow rate of 180 microl/min. The sensitivity of the Spreeta-based biosensor inhibition assays implemented (50% inhibition concentration (IC50) of 30.2 nM for BPA using MAb12 and 12.3 and 11.6 nM for thyroxine (T4) using thyroxine-binding globulin (TBG) and recombinant transthyretin (rTTR), respectively) was comparable to the sensitivity previously obtained using a Biacore 3000 (IC50 of 39.9 nM for BPA and 8.6 and 13.7 nM, respectively, for T4). The results indicate that the alternative prototype system can be used in combination with ready-to-use biosensor chip surfaces and it is potentially a useful tool for the bioeffect-related screening of EDCs.

Benzhydryl Compounds↗

Selective detection and identification of phosphorylated proteins by simultaneous ligand-exchange fluorescence detection and mass spectrometry.

A ligand-exchange method for the detection and identification of phosphorylated peptides in complex mixtures is presented that is based on the characterization of phosphorylated species by solution-phase interactions with Fe(III) ions and subsequent fluorescence readout. After the separation of the peptides and digest products on a reversed-phase LC column, the flow is split between the two detection systems. One part is directed towards an electrospray mass spectrometer for direct detection and identification of all the peptides present in the sample. The other part of the flow is directed towards a ligand-exchange detection system. This system relies on the specific release of a fluorescent reporter ligand from a Fe(III)-complex in the presence of phosphorylated peptides. To recognize false positive signals due to high-affinity non-phosphorylated high-acidic peptides and other compounds which are known to be a problem in for instance immobilized metal affinity chromatography (IMAC), a second run is performed after incubation of the sample with alkaline phosphatase. A positive signal in this second run indicates a high-affinity non-phosphorylated compound. The method is illustrated using digest from a phosphorylated alpha-casein. Automated switching between MS and MS-MS was performed to obtain additional information about the compounds present in the sample. The linearity of the method was tested in the range of 0.5-80 microM of phosphorylated peptides. A limit of detection (LOD) of 0.5 microM was obtained for a mono-phosphorylated peptide. The interday (n=4) and intraday precision (n=3) expressed as relative standard deviation was better than 10%.

Caseins↗

On-line formation, separation, and estrogen receptor affinity screening of cytochrome P450-derived metabolites of selective estrogen receptor modulators.

We have developed a fully automated bioreactor coupled to an on-line receptor affinity detection system. This analytical system provides detailed information on pharmacologically active metabolites of selective estrogen receptor modulators (SERMs) generated by cytochromes P450 (P450s). We demonstrated this novel concept by investigating the metabolic activation of tamoxifen and raloxifene by P450-containing pig and rat liver microsomes. The high resolution screening (HRS) system is based on the coupling of a P450-bioreactor to an HPLC-based estrogen receptor alpha (ERalpha) affinity assay. P450-derived metabolites of the SERMs were generated in the bioreactor, subsequently trapped on-line with solid phase extraction, and finally separated with gradient HPLC. Upon elution, the metabolites were screened on affinity for ERalpha with an on-line HRS assay. With this HRS system, we were able to follow, in a time-dependent manner, the formation of ERalpha-binding metabolites of tamoxifen and raloxifene. By analyzing the bioaffinity chromatograms with liquid chromatography-tandem mass spectrometry, structural information of the pharmacologically active metabolites was obtained as well. For tamoxifen, 15 active and 6 nonactive metabolites were observed, of which 5 were of primary, 10 of secondary, and 6 of an as yet unknown order of metabolism. Raloxifene was biotransformed in three primary and three secondary metabolites. MS/MS analysis revealed that three of the observed active metabolites of raloxifene were not described before. The present automated on-line HRS system coupled to a P450-containing bioreactor and an ERalpha-affinity detector proved very efficient, sensitive, and selective in metabolic profiling of SERMs.

Animals↗

Screening for metal ligands by liquid chromatography--ligand-exchange--electrospray mass spectrometry.

Electrospray ionization mass spectrometry is applied for the selective detection of metal ligands after a post-column continuous-flow ligand-exchange reaction. The detection is based on the specific release of a reporter ligand from a metal-reporter ligand complex by a high affinity ligand. Constant infusion and direct-injection experiments are performed to optimize the method. The on-line coupling of a liquid chromatographic separation prior to the continuous flow ligand-exchange reaction enables the screening for high affinity ligands in complex samples. The feasibility of the method is demonstrated by using several ligands with a different affinity for either Cu(II) or Zn(II) ions. The selectivity of the ligand-exchange detection method can be tuned by the choice of the reporter ligand. This is demonstrated by using either 2,2'-bipyridyl or 5-methyl-1,10-phenanthroline as reporter ligands.

Chromatography, Liquid↗

Sample preparation for peptides and proteins in biological matrices prior to liquid chromatography and capillary zone electrophoresis.

The determination of peptides and proteins in a biological matrix normally includes a sample-preparation step to obtain a sample that can be injected into a separation system in such a way that peptides and proteins of interest can be determined qualitatively and/or quantitatively. This can be a rather challenging, labourious and/or time-consuming process. The extract obtained after sample preparation is further separated using a compatible separation system. Liquid chromatography (LC) is the generally applied technique for this purpose, but capillary zone electrophoresis (CZE) is an alternative, providing fast, versatile and efficient separations. In this review, the recent developments in the combination of sample-preparation procedures with LC and CZE, for the determination of peptides and proteins, will be discussed. Emphasis will be on purification from and determination in complex biological matrices (plasma, cell lysates, etc.) of these compounds and little attention will be paid to the proteomics area. Additional focus will be put on sample-preparation conditions, which can be 'hard' or 'soft', and on selectivity issues. Selectivity issues will be addressed in combination with the used separation technique and a comparison between LC and CZE will be made.

Chromatography, Liquid↗

Systematic development of an enzymatic phosphorylation assay compatible with mass spectrometric detection.

The enzymatic peptide phosphorylation by cAMP-dependent protein kinase A (PKA) was optimized and monitored by means of electrospray ionization mass spectrometry (ESI-MS). The direct detection of phosphorylated peptides by MS renders labeling unnecessary, reduces time and labor, due to less initial sample pretreatment. In this study the phosphorylation of the peptide malantide by PKA was performed in batch and reaction compounds were detected by ESI-MS after the incubation time. The subsequent product quantitation was accomplished by using one-point normalization. Applying this set-up, optimum solvent conditions (such as salt and modifier content), concentrations of essential reaction compounds (such as cAMP, Mg2+ and ATP), and the influence of reaction properties (such as pH and reaction time) were determined. The reaction milieu has to be suitable for both, the enzymatic reaction and the mass spectrometric detection. We found that the modifier content and the pH value had to be changed after the enzymatic reaction occurred. Through the addition of methanol and acetic acid, the reaction stopped immediately and a more sensitive mass spectrometric detection could be obtained simultaneously. Furthermore, an inhibitor study was performed, testing the inhibition potency of three protein kinase A inhibitors (PKIs). IC50 values were determined and used to calculate the Ki values, that were 7.4, 19.0 and 340.0 nmol/L for PKI(6-22)amide, PKI(5-24)amide, and PKI(14-24)amide, respectively. These data vary between factor 4.4 (for PKI(6-22)amide) and 8.3 (for PKI(5-24)amide) compared to the Ki values described in literature. However, the Ki values are in good agreement with the data mainly obtained by fluorescence- or radioactivity-based methods. Nevertheless, our results indicate that ESI-MS is a realistic alternative to radioactivity and fluorescence detection in determining enzymatic activity. Furthermore we were able to illustrate its high potential as a quantitative detection method.

Adenosine Triphosphate↗

Ligand-exchange detection of phosphorylated peptides using liquid chromatography electrospray mass spectrometry.

Electrospray ionization mass spectrometry (ESI-MS) is used to selectively detect analytes with a high affinity for metal ions. The detection method is based on the selective monitoring of a competing ligand at its specific m/z value that is released during the ligand-exchange reaction of a metal-ligand complex with analyte(s) eluting from a reversed-phase liquid chromatography column. The ligand-exchange reaction proceeds in a postcolumn reaction detection system placed prior to the inlet of the electrospray MS interface. The feasibility of metal affinity detection by ESI-MS is demonstrated using phosphorylated peptides and iron(III)methylcalcein blue as reactant, as a model system. Methylcalcein blue (MCB) released upon interaction with phosphorylated peptides is detected at m/z 278. The ligand-exchange detection is coupled to a C8 reversed-phase column to separate several nonphosphorylated enkephalins and the phosphorylated peptides pp60 c-src (P) and M2170. Detection limits of 2 microM were obtained for pp60 c-src (P) and M2170. The linearity of the detection method is tested in the range of 2-80 micromol/L phosphorylated compounds (r(2) = 0.9996), and a relative standard deviation of less than 8% (n = 3) for all MCB responses of the different concentrations of phosphorylated compounds was obtained. The presented method showed specificity for phosphorylated peptides and may prove a useful tool for studying other ligand-exchange reactions and metal-protein interactions.

Chromatography, Liquid↗

On-line SPE-CE for the determination of insulin derivatives in biological fluids.

An on-line SPE-CE system is described for the determination of insulin derivatives in urine, serum and plasma. By combining techniques based on different separation mechanisms, in this case reversed-phase SPE and CE, a more selective sample clean-up is obtained. The described on-line SPE-CE procedure is able to desalt and clean biological samples, resulting in more repeatable electrophoretic results as well as a good linearity for urine, serum and plasma samples spiked with insulin derivatives, thus proving the elimination of detrimental effects caused by the sample matrix. The on-line SPE-CE system was linear for urine, serum and plasma samples spiked with insulin derivatives between 5 and 80 mg/l. The repeatability in migration time was below 1% relative standard deviation (R.S.D.). The repeatability of the peak was better (<2.4% R.S.D.) when no off-line precipitation reaction (<6.2% R.S.D.) was used, proving the beneficial characteristics of on-line sample pretreatment procedures over off-line sample pretreatment procedures which are prone to sample losses and contamination.

Amino Acid Sequence↗

Liquid chromatography coupled on-line to flow cytometry for postcolumn homogeneous biochemical detection.

The feasibility of flow cytometry as read-out principle for homogeneous cell- or bead-based assays coupled on-line to LC is demonstrated using digoxin-coated beads (Dig-Beads) and fluorescent-labeled anti-digoxin (AD-FITC) as model system. The assay is carried out in a postcolumn continuous-flow reaction detection system where the AD-FITC and Dig-Beads are simultaneously added to the eluate of an LC separation column. Binding of AD-FITC to Dig-Beads results in a constant amount of fluorescence associated with the beads, which is detected by the flow cytometer. The presence of active compounds, such as digoxin and its analogues, in the sample will results in a decrease of the AD-FITC-Dig-Bead complex and, consequently, in the bead-associated fluorescence. Hence, the bead-associated fluorescence detected is inversely related to the digoxin concentration. A data-handling algorithm was developed in-house for adequate analysis of raw data output from the flow cytometer. Various conditions that influence the performance of this novel LC-biochemical detection (LC-BCD) system were investigated to determine the optimal settings of the bead-based biochemical interaction. The optimized flow injection bead-based assay was capable of detecting very low concentrations of digoxigenin (0.5 nmol/L), digoxin (0.1 nmol/L), and gitoxigenin (50 nmol/L). The applicability of LC coupled on-line to flow cytometry was demonstrated by the individual detection of digoxin, digoxigenin, and gitoxigenin in a single LC analysis. The successful coupling of LC on-line to flow cytometry principally enables the use of a wide range of new homogeneous assay formats in LC-BCD, such as membrane-bound receptor assays, cell-binding assays, and functional cell-based assays. Next to the ability to use insoluble targets, and also multiplexing assays, i.e., performing a number of assays simultaneously, using color- or size-coded beads becomes at hand in LC-BCD.

Journal Article↗

On-line continuous-flow, multi-protein biochemical assays for the characterization of bioaffinity compounds using electrospray quadrupole time-of-flight mass spectrometry.

The applicability of a homogeneous on-line continuous-flow, multi-protein biochemical assay was demonstrated for the interaction between fluorescein-biotin and streptavidin and for digoxin and anti-digoxigenin using electrospray quadrupole time-of-flight mass spectrometry (Q-TOF MS). In the on-line continuous-flow biochemical MS-based system several receptors (e.g., streptavidin and anti-digoxigenin, respectively) were allowed to react with corresponding reporter ligands (e.g.,fluorescein-biotin and digoxin, respectively). The methodology presented allows the simultaneous measurement of affinity and molecular mass of an active compound. By using automated MS and MS-MS switching functions of the Q-TOF, structure information is obtained allowing the characterization of bioactive compounds. No cross-reactivities were observed between the two model systems fluorescein-biotin/streptavidin and digoxin/anti-digoxigenin.

Algorithms↗

On-line SPE-RP-LC for the determination of insulin derivatives in biological matrices.

An automated and on-line solid-phase extraction (SPE)-liquid chromatography (LC) procedure is described for the determination of insulin in biological matrices. The total procedure consists of two SPEs in series, followed by RP-LC separation. During the first SPE a strong anion-exchange (SAX) cartridge (ISOLUTE, 40-90 microm, 10 x 4 mm i.d.) is used, followed by a RP-cartridge (Luna C(8), 4 x 2.0 mm i.d.). The second SPE cartridge contains the same material as the LC column and is used to transfer the sample from the SAX cartridge to the LC column. The developed system can detect 100 nmol/l insulin in aqueous samples and 200 nmol/l insulin in spiked plasma samples using UV. When electrospray ionization (ESI)-mass spectrometry (MS), was coupled with the developed system, the LODs were lowered by a factor two to 50 and 100 nmol/l for aqueous and spiked plasma samples, respectively.

Amino Acid Sequence↗

A generic assay for phosphate-consuming or -releasing enzymes coupled on-line to liquid chromatography for lead finding in natural products.

A generic continuous-flow assay for phosphate-consuming or -releasing enzymes coupled on-line to liquid chromatography (LC) has been developed. Operating the LC-biochemical assay in combination with mass spectrometry allows the fast detection and identification of inhibitors of these enzymes in complex mixtures. The assay is based on the detection of phosphate, released by the on-line continuous-flow enzymatic reaction, using a fluorescent probe. The probe consists of fluorophore-labeled phosphate-binding protein, which shows a strong fluorescence enhancement upon binding to inorganic phosphate. To detect very small changes of the phosphate concentration in a postcolumn enzymatic reaction medium, the enzymatic removal of phosphate impurities from solvents, reagents, and samples was optimized for application in continuous flow. The potential of the phosphate probe is demonstrated by monitoring the enzymatic activity, i.e., the phosphate release, from alkaline phosphatase. The selectivity of the phosphate readout, necessary to distinguish between phosphate containing substrate or product and free inorganic phosphate released after enzymatic conversion, is shown. The applicability of LC coupled to the enzymatic assay using the phosphate readout was demonstrated by detection of tetramisole in a plant extract as inhibitor of alkaline phosphatase. Parallel mass spectrometry allowed the simultaneous confirmation of the identity of the inhibitor.

Alkaline Phosphatase↗

Screening of natural products extracts for the presence of phosphodiesterase inhibitors using liquid chromatography coupled online to parallel biochemical detection and chemical characterization.

The ability to rapidly identify active compounds in a complex mixture (e.g., natural products extract) is still one of the major problems in natural products screening programs. An elegant way to overcome this problem is to separate the complex mixture by gradient liquid chromatography followed by online biochemical detection parallel with chemical characterization, referred to as high-resolution screening (HRS). To find and identify phosphodiesterase (PDE) inhibitors in natural products extracts using the HRS technology, the authors developed a continuous-flow PDE enzymatic assay. The suitability of the continuous-flow PDE enzymatic assay for natural products screening was demonstrated. After optimization of the continuous-flow PDE assay, the limit of detection for 3-isobutyl-1-methyl-xanthine (IBMX) was 1 muM, with a dynamic range from 1 to 100 muM IBMX. The applicability of the HRS technology for the detection of PDE inhibitors in natural products extracts was demonstrated by the analysis of a plant extract spiked with 2 naturally occurring PDE inhibitors. The plant extract was analyzed with 2 assay lines in parallel, enabling background fluorescence correction of the sample. The simultaneous quantification of the active compounds using evaporative light-scattering detection allowed the estimation of the IC(50) value of the active compounds directly in the crude extract.

1-Methyl-3-isobutylxanthine↗

Effect of the mobile phase composition on the separation and detection of intact proteins by reversed-phase liquid chromatography-electrospray mass spectrometry.

Various buffers (ammonium acetate, ammonium formate, and ammonium hydrogencarbonate), acids (formic acid, acetic acid, heptafluorobutyric acid, and trifluoroacetic acid), and bases (ammonium hydroxide and morpholine) covering the range from 2 to 11.5 have been investigated for their performance in the separation of proteins by reversed-phase liquid chromatography (RPLC) and in their detection by electrospray mass spectrometry (ESI-MS). These additives were first tested for the detection of standard proteins by ESI-MS by flow-injection analysis (FIA). Those additives yielding the highest signals were employed for the separation of standard proteins by using three different reversed-phase columns: two C18 columns (4.6 mm I.D. and 2.1 mm I.D.) and one perfusion column (2 mm I.D.). The sensitivity of the LC-MS system was evaluated with the column giving the best results and with those LC eluents enabling the LC separation of the proteins and also yielding the highest MS signals. For that purpose, calibration curves were compared for both LC-MS and FIA-MS. Formic acid was the additive yielding the highest responses in FIA-MS and trifluoroacetic acid (TFA) gave the best separation and recovery of the proteins. However, problems related to poor recovery of the proteins in the column when formic acid was used and the significant signal suppression observed in MS when TFA was employed, made neither of them suitable for the sensitive detection of the proteins in LC-MS.

Chromatography, Liquid↗

Continuous-flow, on-line monitoring of biospecific interactions using electrospray mass spectrometry.

A continuous-flow analytical screening system is presented using electrospray mass spectrometry to measure the interaction of biologically active compounds with soluble affinity proteins. The biochemical detection system is based on a solution-phase, homogeneous assay. In a first step, compounds to be screened (e.g., biotinylated compounds, concentration range 10-1,000 nmol/L) are injected into a continuous-flow reaction system and allowed to react with the affinity protein (e.g., streptavidin, concentration range 3-48 nmol/L). Subsequently, a reporter ligand (fluorescein-labeled biotin 96 nmol/L) is added to saturate the remaining free binding sites of the affinity protein and the concentration of unbound reporter ligand is measured using electrospray MS in the selectedion monitoring mode. The presence of active compounds in the sample results in an increase of the concentration of unbound reporter ligands. The feasibility of a homogeneous MS-based biochemical assay is demonstrated using streptavidin/biotin and anti-digoxigenin/digoxin as model systems. Compared to radioactive or fluorescence-based biochemical assays, the present assay format does not require the synthesis and purification of labels. Various analytical conditions were investigated to determine the ability of MS to measure the biochemical interactions. The availability of a single ligand that can be detected at 10-50 nmol/L concentrations by electrospray MS is sufficient to set up the biochemical assay. For the biospecific interactions studies, detection limits of 10-100 nmol/L were obtained.

Antigen-Antibody Reactions↗

Potential of on-line micro-LC immunochemical detection in the bioanalysis of cytokines.

An on-line liquid chromatography-immunochemical detection (LC-ICD) system for the quantification of cytokines in cell extracts has been developed using a post-column continuous-flow reaction detection system using fluorescence labelled antibodies. Cytokines eluting from the micro-HPLC column react with antibodies to form fluorescent complexes. In a second step the excess of free antibody is trapped on a cytokine bound support prior to fluorescence detection. The concentration detection limit of the flow injection-ICD system was 50 pM (20 microl injection volume) for interleukin 4 (IL-4). An absolute detection limit of 1 fmol was obtained for IL-4. Similar to ICD systems for small non-protein analytes developed earlier, reaction times were in the order of 1 minute. The immobilised cytokine affinity columns can easily be regenerated and used for months. The present ICD system for interleukins 4, 6, 8 and 10 was coupled to ion exchange-, size exclusion- and reversed phase chromatography. Important parameters (reaction times, reaction conditions) were investigated to get a better understanding of post-column ICD systems for macromolecules.

Chromatography, Gel↗

High resolution screening of plant natural product extracts for estrogen receptor alpha and beta binding activity using an online HPLC-MS biochemical detection system.

A new screening technology that combines biochemical analysis with the resolution power of high-performance liquid chromatography (HPLC), referred to here as high-resolution screening (HRS) technique, is described. The capability of the HRS technology to analyze biologically active compounds in complex mixtures is demonstrated by screening a plant natural product extract library for estrogen receptor (ER) alpha and beta binding activity. The simultaneous structure elucidation of biologically active components in crude extracts was achieved by operating the HRS system in combination with mass spectrometry (MS). In contrast to conventional microtiter-type bioassays, the interactions of the extracts with the ER and the employed label, coumestrol, proceeded at high speed in a closed, continuous-flow reaction detection system, which was coupled directly to the outlet of a HPLC separation column. The reaction products of this homogeneous fluorescence enhancement-type assay were detected online using a flowthrough fluorescence detector. Primary screening of the extract library was performed in the fast-flow injection analysis mode (FlowScreening) wherein the chromatographic separation system was bypassed. The library was screened at high speed, using two assay lines in parallel. A total of 98% of the identified hits were confirmed in a traditional 96-well microplate-based fluorescence polarization assay, indicating the reliability of the FlowScreening process. Active extracts were reassayed in a transcriptional activation assay in order to assess the functional activity of the bioactive extracts. Only functional active extracts were processed in the more time-consuming HRS mode, which was operated in combination with MS. Information on the number of active compounds, their retention times, the molecular masses, and the MS/MS-fingerprints as a function of their biological activity was obtained from 50% of the functional active extracts in real time. This dramatically enhances the speed of biologically active compound characterization in natural product extracts compared to traditional fractionation approaches.

Biological Factors↗

High-performance liquid chromatography of the neuroactive steroids alphaxalone and pregnanolone in plasma using dansyl hydrazine as fluorescent label: application to a pharmacokinetic-pharmacodynamic study in rats.

This report describes a rapid and sensitive analytical method for the quantification of the neuroactive steroids alphaxalone and pregnanolone in rat plasma using derivatization with dansyl hydrazine as fluorescent label. The method involves protein precipitation, alkaline derivatization and extraction of the compounds and internal standard pregnenolone with dichloromethane, followed by isocratic reversed-phase high-performance liquid chromatography on a 3-microm Microsphere C18 column with fluorescence detection at wavelengths 332 nm and 516 nm for excitation and emission, respectively. The mobile phase consists of a mixture of 25 mM acetate buffer (pH 3.7)-acetonitrile (45:55, v/v for alphaxalone and 40:60, v/v for pregnanolone) with a flow-rate of 1 ml/min. The total run time was approximately 35 min. In the concentration range of 0.010-10 microg ml(-1), the intra- and inter-assay coefficients of variation were less than 17% for both methods. In 50 microl plasma samples the corresponding limits of detection were 10 ng ml(-1) (signal-to-noise ratio=3). The utility of the analytical method was established by analyzing plasma samples from rats, which had received an intravenous administration of 5 mg kg(-1) alphaxalone or pregnanolone. Values for clearance, volume of distribution at steady state and terminal half life were 71.9 ml min(-1) kg(-1), 814 mg kg(-1) and 13.5 min for alphaxalone and 69.2 ml min(-1) kg(-1), 1,638 ml kg(-1) and 27.8 min for pregnanolone, respectively. Due to its simplicity and sensitivity this method can be used on a routine basis for pharmacokinetic analysis of neuroactive steroids.