Time-domain and spectral-domain optical coherence tomography in the analysis of brain tumor tissue.

INTRODUCTION: Detection of residual tumor during resection of glial brain tumors remains a challenge because of a low inherent contrast of adjacent edematous brain, the surrounding infiltration zone, and the solid tumor. Therefore, new technologies that may facilitate an intraoperative analysis of the tissue at the resection edge are of great interest to neurosurgeons. MATERIALS AND METHODS: For ex vivo imaging of gliomas in a mouse model and human biopsy specimens of brain tumors and nervous system tissue we have used a time-domain Sirius 713 Tomograph with a central wavelength of 1,310 nm and a coherence length of 15 microm equipped with a mono mode fiber and a modified optical coherence tomography (OCT) adapter containing a lens system for imaging at a working distance of 2.5 cm. A spectral-domain tomograph using 840 nm and 930 nm superluminescence diodes (SLD) with a central wavelength of 900 nm was used as a second imaging modelity. RESULTS: Both time-domain and spectral-domain coherence tomography delineated normal brain, the infiltration zone and solid tumor in murine intracerebral gliomas. Histological evaluation of H&E sections parallel to the optical plain demonstrated that tumor areas of less than a millimeter could be detected and that not only solid tumor, but also brain invaded by a low-density single tumor cells produced an OCT signal different from normal brain. Spectral-domain OCT (SD-OCT) demonstrated a significantly more detailed microstructure of tumor and normal brain up to a tissue depth of 1.5-2.0 mm, whereas the interpretation of time-domain OCT (TD-OCT) was difficult at a tissue depth >1.0 mm. Because of rapid scanning times SD-OCT data could be acquired as 3D data maps, which allowed a multi-planar analysis of the tumor to brain interface. Similar to our findings in experimental gliomas, images of human nervous system tissue acquired using SD-OCT showed a characteristic signal of normal brain tissue and a detailed microstructure of tumor parenchyma. CONCLUSION: Spectral-domain OCT of experimental gliomas and human brain tumor specimens differentiates solid tumor, diffusely invaded brain tissue, and adjacent normal brain based on microstructure and B-scan signal characteristics. In conjunction with the rapid image acquisition rates of SD-OCT, this technology carries the potential of a novel intraoperative imaging tool for the detection of residual tumor and guidance of neurosurgical tumor resections.

Animals↗

Optical coherence tomography for experimental neuroendoscopy.

Optical coherence tomography (OCT) is a non-invasive and non-contact imaging technology that has been applied to several biomedical applications. We have recently demonstrated that OCT allows discrimination of tumor adjacent brain, diffuse and solid tumor tissue and that this technology may be used to detect residual tumor within the resection cavity during resection of intrinsic brain tumors. Here we show that an OCT integrated endoscope can image the endoventricular anatomy and other endoscopically accessible structures in a human brain specimen. A Sirius 713 optical coherence tomography device was mounted to a modified rigid endoscope. A formalin-fixed human brain specimen was used to simulate endoscopic visualization of brain anatomy and two specimens of fixed malignant tumors with endoventricular growth patterns. Simultaneous OCT imaging and endoscopic video imaging of the visible spectrum was possible using a graded index rod endoscope. OCT imaging of a human brain specimen in water allowed an in-depth view into structures like the walls of the ventricular system, the choroid plexus or the thalamostriatal vein. OCT further allowed imaging of structures beyond tissue barriers or opaque media. In this fixed specimen OCT allowed discrimination of vascular structures down to a diameter of 50 mum. In vessels larger that 100 mum the lumen could be discriminated and within larger blood vessels a layered structure of the vascular wall as well as endovascular plaques could be visualized. This in vitro pilot study has demonstrated that OCT integrated into neuroendoscopes may add information that cannot be obtained by the video imaging alone. This technology may provide an extra margin of safety by providing cross-sectional images of tissue barriers within optically opaque conditions.

Brain↗