PubMed Health⌕ Search

Biomedical subjects

H J Bender

Publications and source records attributed to H J Bender.

28 records · Page 2Linked to original sources

[Effects of positive end-expiratory pressure (PEEP) or prolonged inspiration time on lung mechanics, gas exchange and hemodynamics in differential pulmonary ventilation].

In the case of patients with unilateral lung disorders one must anticipate a further increase in the intake volume of the more elastic lung and a decrease in intake volume of the less elastic lung when the inspiratory pressure is increased or the inspiratory time is extended within the framework of mechanical ventilation. Therefore, differential pulmonary ventilation lends itself for the treatment of unilateral damage of the lung by enabling the selective application of a positive end-expiratory pressure or an inverse inspiratory time. For a better understanding of the overlapping pathophysiologic reactions, the changes in lung mechanics, haemodynamics and gas exchange were measured on the healthy lung with unilateral application of a positive and expiratory pressure or an increased inspiratory time. Thirteen male and female patients, who had to undergo intracranial surgery were ventilated with two synchronized servoventilators using a Carlens tube. The positive end expiratory pressure varied in the right lung in spans of 6 cm each, 0-12 cm H2O, inspiratory time varied 34-70%. The left lung was ventilated with a 35% inspiratory time and an end expiratory pressure of 0. The respiratory intake volume was divided up into 45% (left lung) and 55% (right lung) based on the physiological difference in size between the left and right lung. Our results show that a directed unilateral application of a positive end expiratory pressure or an increased inspiratory time does not have any relevant damaging effects on the other lung. It can be expected that in the case of non-differentiated mechanical ventilation the ensuing unequal distribution of alveolar ventilation and perfusion with consecutive increase of intrapulmonary shunt volume can be decreased by the discriminate treatment of each lung.

Adult↗

[Is the demand for a preoperative routine examination program justified?].

In a retrospective study with 136, 943 general and regional anaesthesias we demonstrated that the frequency of intraoperative cardiovascular complications is directly connected to the quality of preoperative examination and therapy proceedings. In addition to a careful preoperative clinical examination, a routine examination programme (REP) therefore should be carried out which determines relevant functional disorders of the essential organs and which gives the essential condition for an optimal preparation for surgery.

Anesthesia, Conduction↗

[Time and incidence of peroperative cardiovascular complications in geriatric patients].

The incidence of intraoperative and postoperative complications was determined in a retrospective study via data evaluation by computer. Two groups of patients were examined, one group comprising patients below 60 years of age, whereas the other group consisted of persons above 60 years of age. The results show that complications of the cardiovascular system are three to four times more frequent in patients older than 60 years; severe hypotension or hypertensive reactions were seen in 2.9 and 9.3% of the patients, respectively, while arrhythmias occurred in 3.9%. No differences could be found in respect of the time at which these complications became manifest (intraoperatively or in the recovery room). Enumeration of the secondary diseases covered by this study, reveals significant differences; this can explain the limited range of compensation in persons of advanced age. Hence, an optimal preanaesthetic treatment and diagnosis, as well as monitoring are mandatory in geriatric patients to ensure safe anaesthesia.

Age Factors↗

[On-line acquisition of haemodynamic and respiratory data during anaesthesia].

A system is presented which in connection with monitors commonly used affords high resolution control of pulmonary mechanics, respiratory and haemodynamic parameters during surgery. Extent of monitoring as well as choice of the parameters to be monitored is not determined by the system but by the physician concerned. The essential part of the system is a microprocessor in control of all monitors connected, which can store the accumulated data for a 24 hour period. On application in over 200 anaesthetics acceptance by the user was good. Because of the still rather complicated technical procedure use of the system during minor surgery proved to be difficult.

Anesthesia, General↗

[Development and use of a computerized anesthesia protocol].

The real-time anaesthetic record allows the continuous on-line monitoring and the informative graphical presentation of important anaesthetic parameters; in this respect it is superior on the conventional made record. Preoperative findings and personal data of the patient are documented and presented by the aid of formulas on the terminal screen in addition to the on-line parameters and intraoperative off-line data e.g. drugs infusions, urine production, blood loss. The concept of the system is based on a microprocessor which is linked to daily used monitors by an analog-digital-converter. The wide use of the automatic record requires a relative high standard of monitors (e.g. mass spectrography), such that the applicability is limited to very extensive procedures of high risk patients.

Anesthesiology↗

[Incidence of complications with plexus anaesthesia; a computer-assisted evaluation (author's transl)].

4,042 plexus anaesthesias were analysed for systemic complications by means of computer-assisted data processing. This allowed the large case material to be analysed statistically in great detail. The incidence of complications of this anaesthetic technique and the advantages arising from computer-assisted data processing are reviewed. Specific problems due to technical factors were also investigated.

Anesthesia, Conduction↗

[The risk of anaesthesia. Investigations based on 153,660 anaesthetic procedures (author's transl)].

153,660 protocols of general and local anaesthesias were evaluated according to the complications observed during anaesthesia. The complications recorded were analysed with respect to the following criteria: type of anaesthetic procedure, experience of the anaesthesiologist, urgency of the operation and pre-operative condition (risk group) of the patient. The study shows that under the requirements of anaesthetic treatment at a university clinic, the degree of risk connected with anaesthesia is only slightly dependent on the type of the anaesthetic procedure and the experience of the physician performing the anaesthesia. Distinct differences in the complications recorded are found to be dependent on the urgency of the operation (cardiovascular and technical complications) and on the pre-operative condition of the patient (cardiovascular complications). A further decrease of the anaesthetic risk is only possible if all measures for optimal preparation before an operation are fully met and compromises are avoided to the utmost. However, spectacular improvement must not be expected with these measures.

Anesthesia↗

[Data processing system for patients requiring artificial ventilation (author's transl)].

In the surgical intensive care unit of the Mannheim medical Centre a computer program has been developed to assist in the management of patients suffering from ARDS. It is based on a Dietz MUL-TI-USER system. 34 parameters of pulmonary mechanics, hemodynamics and blood gases were recorded off-line routinely. From these data 8 parameters were calculated according to established physiological relationships. Apart fom normal data printout a terminal scope offers graphical display of the interaction of any two parameters chosen. Data may be averaged regarding single patients, groups of patients or time. Data may be stored as hard copies. Operating instructions are very simple. Off-line data feeding is of advantage regarding data allocation, Calibration and plausibility control. We report on the development of the off-line computer system and on clinical efficiency and accuracy of the system in the treatment of patients in respiratory distress.

Adult↗