PubMed Health⌕ Search

Biomedical subjects

H J Busscher

Publications and source records attributed to H J Busscher.

At least 19 recordsLinked to original sources

A method to study sustained antimicrobial activity of rinse and dentifrice components on biofilm viability in vivo.

AIM: To develop an improved method for quantitative assessment of antimicrobial efficacy and substantivity of mouth rinses and dentifrices on in vivo treated plaque. MATERIAL AND METHODS: Nine- and 72-h-old plaques were formed in volunteers carrying out standardized hygiene using NaF-containing dentifrice. Plaques were collected before (baseline) in vivo treatment with dentifrices or chlorhexidine mouth rinse, immediately post-treatment and after 1 or 6 h, dispersed in demineralized water and stained with live/dead stain after which bacteria were enumerated. Dispersed baseline plaques were treated with dentifrices or chlorhexidine to determine antimicrobial efficacy against planktonic bacteria. RESULTS: Baseline plaques revealed 56-41% viable organisms in 9- and 72-h-old plaques, respectively. Treatment of planktonic (dispersed baseline plaque) bacteria resulted in 1-4% viable organisms. Chlorhexidine mouth rinse and dentifrices produced strong immediate antimicrobial effects, but after 1 or 6 h, the proportion of viable organisms in 9-h-old plaques rebounded significantly with only chlorhexidine mouth rinse retaining significant efficacy. Seventy-two-hour-old plaques were less susceptible to antimicrobials, although dentifrices appeared more effective after 6 h than initially, whereas efficacy of chlorhexidine rinse continued to drop with time post-treatment. CONCLUSIONS: The proposed method holds promise for assessment of both immediate and retained antimicrobial actions of oral treatments against dental plaque in vivo.

Anti-Infective Agents, Local↗

Influence of biosurfactant on interactive forces between mutans Streptococci and enamel measured by atomic force microscopy.

Although interactive forces, influenced by environmental conditions, between oral bacteria and tooth surfaces are important for the development of plaque, they have never been estimated. It is hypothesized that interactive forces, as measured by atomic force microscopy, between enamel with or without a pellicle and two strains of mutans streptococci become less attractive by the application of a Streptococcus mitis BMS biosurfactant coating. Upon approach of each of the strains toward bare and pellicle-coated enamel, adsorbed biosurfactant increased the range of the repulsive forces. Upon retraction of the enamel surface, small adhesion forces (0.8-0.9 nN) were measured for bare enamel that almost disappeared after biosurfactant coating. The prevalence and magnitude of the adhesion forces also decreased upon pellicle-coating of the enamel, with a minor effect of adsorbed biosurfactant. These findings indicate that adsorbed S. mitis BMS biosurfactant changes the interactive forces between the mutans streptococci studied and enamel, explaining the effects of biosurfactant on adhesion.

Adsorption↗

Interactive forces between co-aggregating and non-co-aggregating oral bacterial pairs.

The temporo-spatial development of plaque is governed by adhesive interactions between different co-aggregating bacterial strains and species. Physico-chemically, these interactions are due to attractive Lifshitz-Van der Waals and acid-base forces, and occur despite electrostatic repulsion and with a critical influence of temperature. The forces between co-aggregating and non-co-aggregating pairs have never been measured, however. The aim here, thus, is to investigate, by atomic force microscopy, whether there is a difference in interactive forces between co-aggregating and non-co-aggregating bacterial pairs at 10 degrees C, 22 degrees C, and 40 degrees C. Actinomyces naeslundii 147 was immobilized on poly-L-lysine-coated tipless AFM cantilevers, while streptococci were immobilized on poly-L-lysine-coated glass surfaces. Upon approach, a repulsive force was measured, regardless of whether a co-aggregating or non-co-aggregating pair was involved. However, upon retraction, the co-aggregating pair exhibited larger adhesive forces and energies than did the non-co-aggregating pair. Adhesive interactions between the co-aggregating pair were smallest at 40 degrees C.

Actinomyces↗

Evaluation of measures to decrease intra-operative bacterial contamination in orthopaedic implant surgery.

The aim of this study was to evaluate whether behavioural and systemic measures will decrease intra-operative contamination during total hip or knee replacements. The influence of these measures on subsequent prolonged wound discharge, superficial surgical site infection and deep periprosthetic infection was also investigated during an 18-month follow-up period. Four swabs were taken from instruments at the beginning and end of the procedure for 207 procedures. Removed bone material (acetabulum and femur in case of the hip joint; femur and tibia in case of the knee joint) was also tested for contamination. Initially, 70 operations performed under original control conditions were included, after which the first behavioural measure was introduced (i.e. better use of the plenum). Cultures were taken during 67 operations using better use of the plenum (Group 1), followed by disciplinary measures and the installation of a new laminar flow system. Seventy operations were monitored after this second intervention (Group 2). The control group showed intra-operative contamination in 32.9% (23/70) of cases, Group 1 showed contamination in 34.3% (23/67) of cases and Group 2 showed contamination in 8.6% (6/70) of cases. Prolonged wound discharge and superficial surgical site infection decreased significantly in Group 2, as did the incidence of deep periprosthetic infection; however, the latter did not reach statistical significance. This study shows that the combination of systemic and behavioural changes in an operating room significantly decreases the incidence of intra-operative bacterial contamination, subsequent prolonged wound discharge and superficial surgical site infection. After 18 months of follow-up, there was also a decrease in deep periprosthetic infection.

Arthroplasty, Replacement, Hip↗

Electric block current induced detachment from surgical stainless steel and decreased viability of Staphylococcus epidermidis.

In vitro studies investigating the influence of electric DC current on bacterial detachment have demonstrated that continuous currents of only 25-125 microA stimulated staphylococcal strains to detach from surgical stainless steel. However, DC currents produce more power that has to be dissipated by the skin as compared to alternating currents. Also, an excess of ions on the steel can cause negative osteogenesis and fixation results. Therefore, it is the aim of this paper to examine whether detachment of Staphylococcus epidermidis from stainless steel surfaces in a parallel plate flow chamber can also be stimulated using electric block currents. Block currents of 15, 60 and 100 microA with different frequencies (0.1-2 Hz) and duty cycles (5-50%) were applied to induce bacterial detachment. Block currents of 100 microA cause detachment of about 76% of adhering staphylococci from stainless steel, whereas in addition the remaining bacteria are less viable, as determined by culturing the remaining bacteria on agar plates. Therewith, block current-induced detachment of adhering bacteria from stainless steel appears to be an equally promising method to prevent infection of orthopaedic fixation pins and screws than application of DC currents.

Adsorption↗

Effect of pulsed ultrasound in combination with gentamicin on bacterial viability in biofilms on bone cements in vivo.

AIMS: The aim of this study is to investigate whether pulsed ultrasound (US) in combination with gentamicin yields a decreased viability of bacteria in biofilms on bone cements in vivo. METHODS AND RESULTS: Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a rabbit model. Two bone cement samples with an Escherichia coli ATCC 10798 biofilm were implanted in a total of nine rabbits. In two groups bone cement discs loaded with gentamicin, freshly prepared and aged were used, and in one group unloaded bone cement discs in combination with systemically administered gentamicin. Pulsed ultrasound with a frequency of 28.48 kHz and a maximum acoustic intensity of 500 mW cm(-2) was applied continuously from 24 h till 72 h postsurgery on one of the two implanted discs. After euthanization and removal of the bacteria from the discs, the number of viable bacteria were quantified and skin samples were analysed for histopathological examination. Application of ultrasound, combined with gentamicin, reduced the viability of the biofilms in all three groups varying between 58 and 69% compared with the negative control. Histopathological examinations showed no skin lesions. CONCLUSIONS: Ultrasound resulted in a tendency of improved efficacy of gentamicin, either applied locally or systemically. Usage of ultrasound in this model proved to be safe. SIGNIFICANCE AND IMPACT OF THE STUDY: This study implies that ultrasound could improve the prevention of infection immediately after surgery, especially because the biomaterials, gentamicin and ultrasound used in this model are all in clinical usage, but not yet combined in clinical practice.

Animals↗

Bacterial survival in the interfacial gap in gentamicin-loaded acrylic bone cements.

Clinical experience indicates the beneficial effects of antibiotic-loaded bone cement. Although in vitro studies have shown the formation of a biofilm on its surface they have not considered the gap between the cement and the bone. We have investigated bacterial survival in that gap. Samples with gaps 200 microm wide were made of different bone cements. These were stored dry ('pre-elution') or submersed in phosphate-buffered saline to simulate the initial release of gentamicin ('post-elution'). The gaps were subsequently inoculated with bacteria, which had been isolated from infected orthopaedic prostheses and assessed for their sensitivity to gentamicin. Bacterial survival was measured 24 hours after inoculation. All the strains survived in plain cements. In the pre-elution gentamicin-loaded cements only the most gentamicin-resistant strain, CN5115, survived, but in post-elution samples more strains did so, depending on the cement tested. Although high concentrations of gentamicin were demonstrated in the gaps only the gentamicin-sensitive strains were killed. This could explain the increased prevalence of gentamicin-resistant infections which are seen clinically.

Anti-Bacterial Agents↗

Electric-current-induced detachment of Staphylococcus epidermidis strains from surgical stainless steel.

Infection of percutaneous biomaterials implants, such as fixation frames used for the repair of complicated fractures in orthopedics, is a major complication that almost inevitably leads to replacement of the implant. As antibiotic therapy usually has little impact on biomaterial-associated infections, it is the aim of this article to examine whether implant-associated Staphylococcus epidermidis and Staphylococcus aureus strains could be stimulated to detach from a surgical stainless steel anode during application of an electric current. First, bacteria were allowed to adhere from a flowing suspension of physiological ionic strength in a parallel plate flow chamber to a stainless-steel surface, after which the suspension was replaced by a bacterium-free solution with a specified ionic strength (0.5-150-mM potassium phosphate). DC currents ranging from 15 to 125 microA were applied to induce bacterial detachment. Initial detachment decreased with increasing ionic strength at 100 microA. The percentage detachment achieved by application of an electric current after 2.5 h was highest (95%) in 1-mM potassium phosphate and decreased to 15% when the ionic strength exceeded 40 mM. The electric current did not significantly affect the percentage detachment, but initial detachment rates increased with increasing current from 1000 cm(-2) s(-1) at 15 microA to 7000 cm(-2) s(-1) at 125 microA. Although different isolates of S. epidermidis and S. aureus showed different patterns of current-induced detachment, all strains could be stimulated to detach. The results of this study define ionic-strength conditions and electric currents yielding staphylococcal detachment from surgical stainless steel and therewith point to a pathway for the treatment and prevention of percutaneous metal-implant infection.

Electric Stimulation↗

Backgrounds of antibiotic-loaded bone cement and prosthesis-related infection.

Antibiotic-loaded bone cement has been in use for over 30 years for the fixation of total joint arthroplasties, although its mechanism of action is still poorly understood. This review presents the backgrounds of bone cements, prosthesis-related infection and antibiotic-loaded bone cements. It is shown that antibiotic-loaded bone cement has a significant effect on bacteria, particularly in animal and clinical studies. However, recently, antimicrobial resistance among bacteria has been ascribed to the antibiotic-loaded bone cement. The unresolved issues both regarding the action of antibiotic-loaded bone cement and the nature of the antimicrobial resistance necessitate further research into the interaction of antibiotic-loaded bone cement and bacteria.

Animals↗

Multiple surface properties of worn RGP lenses and adhesion of Pseudomonas aeruginosa.

The aim of this study is to determine rigid gas permeable (RGP) lens surface properties prior to and after wear that are influential on adhesion of Pseudomonas aeruginosa. After 10 and 50 days of wear and after end-stage use, lenses were collected for determination of physico-chemical surface properties and bacterial adhesion in a parallel plate flow chamber. Water contact angles on unused RGP lenses amounted 47+/-13 degrees and were affected by wear. In addition, %O at the lens surfaces, as determined by X-ray photoelectron spectroscopy increased after use for 10 and 50 days, but decreased after end-stage wear. The %N hardly increased after wear and, in line, SDS-PAGE did not indicate adsorbed proteins. The surface roughness of the lenses, as measured by atomic force microscopy amounted 9 nm after 10 and 50 days of use, but end-stage lenses were significantly rougher (48+/-23 nm). Moreover, initial deposition of P. aeruginosa #3 increased with increasing roughness for end-stage lenses. Multiple regression analysis, however, revealed that both physical and chemical surface properties were predictive for initial bacterial deposition to lens surfaces. After 10 days of wear, bacterial deposition was governed by the water contact angle, surface roughness, %O, %N, and %Si, while after 50 days of wear the surface roughness, %N, and %Si were found predictive for bacterial deposition. Initial bacterial deposition to end-stage lenses was solely dependent on the surface roughness. Summarizing, physico-chemical surface properties of RGP lenses change slightly during the first 10-50 days of wear, but end-stage lenses all had increased surface roughness, concurrent with increased bacterial adhesion.

Bacterial Adhesion↗

On the influence of flow conditions and wettability on blood material interactions.

In this review, we hypothesise that, next to biocompatibility, optimal blood compatibility depends on a combination of biomaterials wettability and the shear stress prevailing in the device. The wettability is discussed in seven different categories of devices, that differ substantially from each other with regard to shear stress and exposure time. These seven categories are stents, prosthetic heart valves, vascular prostheses, cardiopulmonary bypass, hemodialysis, vena cava filters and blood bags. In high shear applications, in combination with blood activation, platelet deposition and thrombosis appear to be major problems and platelet inhibitors are most effective. Exposure of blood to a large biomaterial surface, with or without antithrombotic coating, results in reduction of platelet function. Material-independent activation aggravates this process. In low shear applications, platelets only seem supportive for coagulation and anticoagulants should be used.

Animals↗

Influence of the Provox Flush, blowing and imitated coughing on voice prosthetic biofilms in vitro.

OBJECTIVE: This study investigates the effect of regular airflow, as an isolated single factor, through Groningen and Provox2 voice prostheses on biofilm formation. MATERIAL AND METHODS: Groningen and Provox2 voice prostheses were placed in a modified Robbins device and inoculated with the total microflora from an explanted Groningen voice prosthesis. After 3 days, prostheses were either flushed 3 times per day with the Provox flush, treated with an airflow using an increasing order of air pressure (10, 15 and 20 cmH2O) or vigorously perfused by means of imitated coughing (air pressure 20 cmH2O). As a control, prostheses were left undisturbed to promote biofilm growth. Following flushing, blowing or coughing, each artificial throat was perfused with 200 ml of phosphate-buffered saline. This procedure was repeated three times a day for 9 days. At the end of each day, the artificial throats were filled with growth medium for 30 min and left empty during the night after draining. After 12 days the microflora on each voice prosthesis was quantified by plating on blood agar for bacteria and on de Man, Rogosa and Sharpe agar for yeasts. RESULTS: The use of the Provox flush reduced bacterial prevalence on Groningen and Provox2 voice prostheses to 71% and 45% of the control values, respectively, without affecting the number of yeasts. Increasing airflows and imitated coughing yielded reductions of 45-70% in bacterial and yeast prevalence on Provox2 voice prostheses. On the Groningen voice prostheses the effects of increasing airflows and imitated coughing were less pronounced: reductions in bacterial and yeast prevalence of 56-87% were observed. CONCLUSION: This study shows that use of the Provox flush has a cleansing effect, especially on Provox2 voice prostheses, and furthermore suggests that daily airflow through voice prostheses as part of a daily maintenance scheme reduces biofilm formation and can be expected to prolong the life of these devices.

Air↗

Non-contact removal of coadhering and non-coadhering bacterial pairs from pellicle surfaces by sonic brushing and de novo adhesion.

Coadhesion between oral microbial pairs is an established factor in the spatiotemporal development and prevalence of mixed-species communities in early dental plaque in vivo. This study compares removal and de novo adhesion of pairs of coadhering and non-coadhering oral actinomyces and streptococci by sonic brushing on salivary pellicles in a non-contact mode as a function of the distance between the brush and the pellicle surface in vitro. First, actinomycetes were adhered to a pellicle surface, after which streptococci suspended in saliva were allowed to adhere. Removal was examined by non-contact, sonic brushing with a wetted brush on a either a wetted or a substratum immersed to a depth of 7 mm. After brushing, de novo adhesion of streptococci to brushed pellicles was studied. For coadhering and non-coadhering pairs, 34% and 9%, respectively, of the adhering bacteria were involved in aggregates comprising more than 10 organisms. Non-contact, sonic brushing removed up to 99% of the adhering bacteria, regardless of the state of immersion of the substratum. Bacterial removal decreased with increasing distance of up to 6 mm between brush and pellicle surface. For the non-coadhering pair, subsequent exposure of pellicles to a streptococcal suspension yielded about 6% of bacteria involved in large aggregates. Alternatively, de novo adhesion of the coadhering streptococcal strain to pellicles brushed on the wetted substratum yielded 31% of bacteria involved in large aggregates, but after brushing the immersed substratum only 12% of the adhering bacteria were found in large aggregates. It is concluded that non-contact sonic brushing, under immersion, removes high percentage of adhering bacterial pairs up to a distance of 6 mm between the brush and the pellicle surface. However, non-contact, sonic brushing with only a thin wet film on the substratum may leave footprints to which streptococci preferentially adhere.

Actinomyces↗

Comparison of velocity profiles for different flow chamber designs used in studies of microbial adhesion to surfaces.

Flow chambers are commonly used to study microbial adhesion to surfaces under environmentally relevant hydrodynamic conditions. The parallel plate flow chamber (PPFC) is the most common design, and mass transport occurs through slow convective diffusion. In this study, we analyzed four different PPFCs to determine whether the expected hydrodynamic conditions, which control both mass transport and detachment forces, are actually achieved. Furthermore, the different PPFCs were critically evaluated based on the size of the area where the velocity profile was established and constant with a range of flow rates, indicating that valid observations could be made. Velocity profiles in the different chambers were calculated by using a numerical simulation model based on the finite element method and were found to coincide with the profiles measured by particle image velocimetry. Environmentally relevant shear rates between 0 and 10,000 s(-1) could be measured over a sizeable proportion of the substratum surface for only two of the four PPFCs. Two models appeared to be flawed in the design of their inlets and outlets and allowed development of a stable velocity profile only for shear rates up to 0.5 and 500 s(-1). For these PPFCs the inlet and outlet were curved, and the modeled shear rates deviated from the calculated shear rates by up to 75%. We concluded that PPFCs used for studies of microbial adhesion to surfaces should be designed so that their inlets and outlets are in line with the flow channel. Alternatively, the channel length should be increased to allow a greater length for the establishment of the desired hydrodynamic conditions.

Bacterial Adhesion↗

The influence of a hexametaphosphate-containing chewing gum on the wetting ability of salivary conditioning films in vitro and in vivo.

OBJECTIVE: Adsorbed conditioning films of salivary components on dental enamel surfaces or pellicles form the interface between teeth and the oral environment. The wetting ability of salivary conditioning films dictates biological adhesion phenomena such as plaque formation, calcification and staining, and also influences mouth perception through effects on lubricity. This study assessed the effects of hexametaphosphate release from a chewing gum matrix on the wetting ability of salivary conditioning films in vitro and in vivo. METHODOLOGY: Results obtained for hexametaphosphate chewing gum were compared with those produced by hexametaphosphate-containing dentifrice, which has been clinically proven to have efficacy for stain removal and prevention and dental calculus prevention. RESULTS: Contact angle assessments revealed that hexametaphosphate dentifrice produced markedly hydrophilic conditioning films in vitro. Hexametaphosphate chewing gums had only minor effects on surface contact angles in vitro. However, in vivo intra-oral contact angle measurements on tooth surfaces in volunteers showed that both hexametaphosphate dentifrice and chewing gum produced more hydrophilic tooth surfaces. CONCLUSION: These results support the activity of hexametaphosphate on tooth surfaces delivered both from dentifrice and chewing gum forms.

Adhesiveness↗

Bacterial adhesion to titanium-oxy-nitride (TiNOX) coatings with different resistivities: a novel approach for the development of biomaterials.

In this study the quantitative adhesion of a strain of Staphylococcus epidermidis, Streptococcus mutans and Pseudomonas aeruginosa to and the ease of removal from different TiNOX coatings was investigated by means of a parallel plate flow chamber and in situ image analysis. Quality of adhesion was determined by counting bacteria which remained attached to the surface after exposure to an air-liquid interface. S. epidermidis and S. mutans showed a bipolar adhesion pattern with highest numbers of adhesion at low and high resistivity with lowest adhesions at a resistivity of 10(4) microohms cm. P. aeruginosa was the least adherent organism. These results indicate that the affinity of these three strains under the current experimental conditions is minimal for TiNOX coatings with a specific resistivity. TiNOX coatings with pre-adsorbed fibrinogen showed different numbers of S. epidermidis adhered to the different coatings. However, the affinity of this strain for fibrinogen-coated TiNOX remains low when the resistivity is around 10(4) microohms cm. This indicates that the specific influence of the resistivities of the TiNOX coatings is transferred through the adsorbed fibrinogen film to the interface with adhering bacteria.

Adsorption↗

Pathogenesis and prevention of biomaterial centered infections.

One of the major drawbacks in the use of biomedical materials is the occurrence of biomaterials centered infections. After implantation, the host interacts with a biomaterial by forming a conditioning film on its surface and an immune reaction towards the foreign material. When microorganisms can reach the biomaterials surface they can adhere to it. Adhesion of microorganisms to an implant is mediated by their physico-chemical surface properties and the properties of the biomaterials surface itself. Subsequent surface growth of the microorganisms will lead to a mature biofilm and infection, which is difficult to eradicate by antibiotics. The purpose of this review is to give an overview of the mechanisms involved in biomaterials centered infection and the possible methods to prevent these infections.

Journal Article↗