The reliability of plain radiography in experimental fracture healing.

OBJECTIVE: To investigate the reliability of radiographs in the evaluation of healing of closed fractures. DESIGN: A closed midshaft tibial fracture was created in 40 goats and stabilized with an external fixator. The animals were assigned to four groups: no injection, injection of 1 mg osteogenic protein-1 (OP-1), 1 mg OP-1 with collagenous carrier, or carrier alone. Radiographs were performed weekly until the animals were killed after 2 and 4 weeks. Healing was evaluated using radiographs, biomechanical testing, and histological examination. All radiographs were examined by two independent observers. Interobserver agreement was calculated and radiographic scores were compared with mechanical and histological scores using regression analysis. RESULTS: Regression analysis showed poor correlation between radiographic scores and biomechanical and histological data. Correlation coefficients varied between 0.39 and 0.63. Good agreement between the observers was seen in only three parameters: visibility of the fracture line, weightbearing ability, and a combined healing parameter. CONCLUSION: Plain radiography provides poor parameters for monitoring the fracture healing process.

Animals↗

The assessment of cortical heat during intramedullary reaming of long bones.

BACKGROUND: This experimental study was designed to compare different in vitro methods of measuring the cortical temperature when reaming the medullary cavity. This was done to validate an approved mathematical model which can be used to determine the temperature gradient in cortical bone in the presence or absence of sensors. METHODS: Artificial bone was used with an intramedullary heat source instead of a reamer. Temperatures were measured with thermocouples placed radially and axially in the cortical wall. This method with these two measurement positions were compared and used to validate an approved mathematical model. This model was used to determine the temperature gradient in cortical bone in the absence of sensors. RESULTS: The measurement of the cortical temperature with the thermocouples in a radial position only reflects maximally 14% of the temperature of the reamer (calculated 55%). The measurement with the thermocouples in axial position reflects maximally 65% (calculated 70%) of the reamer temperature, which is similar to undisturbed bone. CONCLUSION: The measuring method with the thermocouples in a radial position cannot be recommended. It is likely that a much higher temperature is generated and conducted through reaming than has been assumed until now.

Bone and Bones↗

Biomechanical and histological aspects of fracture healing, stimulated with osteogenic protein-1.

Fracture healing could be stimulated with osteoinductive bone morphogenetic proteins (bmp's), such as osteogenic protein-1 (OP-1), but little is known about its effectiveness in stimulation of fracture healing. In this study, biomechanical and histological aspects of fracture healing after an injection of OP-1 in the fracture gap were investigated. In 40 goats, a closed fracture was created in the left tibia. The fractures were stabilized with an external fixator and the animals were assigned to four different groups: no injection, injection of 1 mg OP-1, injection of 1 mg OP-1 with collagenous carrier material, and injection of carrier material alone. Twenty-one animals were sacrificed after 2 weeks and 19 after 4 weeks. Biomechanical testing was perfomed on both explanted tibiae. Four longitudinal samples of the fracture were sawn, processed for histology, and examined by two observers. Biomechanical evaluation showed a higher stiffness and strength at 2 weeks after injection of OP-1. Histological evaluation showed normal fracture healing patterns in all animals without adverse effects of the given injections. These data show that fracture healing can be accelerated with a single injection of OP-1, eventually resulting in normally healed bone.

Animals↗

Reaming debris in osteotomized sheep tibiae.

BACKGROUND: Reamed nailing gives better fracture healing than unreamed nailing in operative treatment of fractures and nonunions. This study investigates the effect of isolated reaming debris on fracture healing in an animal model. METHODS: Thirty sheep were treated with an osteotomy of the tibia with 5-mm distraction. In one group, the osteotomy gap was left empty; in the second group, the gap was packed with reaming debris from the ipsilateral femur; and in the third group, the gap was packed with cancellous bone from the iliac crest. At follow-up, callus volume was measured on standard radiographs. RESULTS: After 3 weeks, callus volume from the reaming debris group as well as the iliac crest group had increased significantly compared with the empty group. CONCLUSION: This study shows that isolated reaming debris supports callus building as much as conventional bone grafting, which might explain why fractures heal with more callus formation when treated with reamed nailing compared with unreamed nailing.

Animals↗

Traumatic rupture of the thoracic aorta: time to diagnosis and treatment.

Survival of patients with traumatic rupture of the thoracic aorta (TRTA) depends on early surgical repair. Six cases of TRTA were treated at our institution in 7 years. Time to diagnosis was 1.5, 3, 4, 36, 91 and 140 hours (mean = 46 hours). Diagnosis was made by computed tomography in one and by angiography in five cases. Time from arrival to treatment was 3, 9, 5, 46, 117 and 152 hours (mean = 55 hours). All six patients were treated by clamp and suture technique, with a mean cross clamp time of 48 minutes. Significant delay in diagnosis and treatment occurred in three patients. The reasons for delay were unrecognized signs for TRTA on the initial chest X-ray, a false-negative result of transoesophageal echography and not considering the diagnosis of TRTA. The diagnosis of TRTA requires a high index of suspicion and should always be considered in victims of high impact trauma.

Adult↗

Resorbable calcium phosphate particles as a carrier material for bone marrow in an ovine segmental defect.

Resorbable calcium phosphate ceramics are only osteoconductive; therefore, their combination with osteogenic substances may lead to stimulation of bone healing. In the present study this combination, using autologous bone marrow, was investigated. In 31 sheep, a 3-cm tibial segmental defect was created and stabilized with an intramedullary nail. The animals were divided into four groups: empty defects (group 1, n = 7), and defects filled with 10-mL dense resorbable calcium phosphate particles (group 2, n = 8), with 10-mL particles soaked in bone marrow (group 3, n = 8), or with 10-mL autologous bone (group 4, n = 8). On evaluation after 12 weeks, significantly higher values were seen in group 3 than in group 2 for callus volume (p = .016), bone mineral density ratio (p = .03), bone mineral content ratio (p = .04), torsional strength (p = .005), and torsional stiffness (p = .01). For all end points, the outcome of group 3 was lower than that of group 4. In the histology, there was direct contact between newly formed bone and remnants of the particles. There were no signs of inflammatory reactions. Although a stimulatory effect of bone marrow was seen, the combination of resorbable calcium phosphate particles with bone marrow does not provide an alternative for autologous bone grafting.

Animals↗

Evaluation of strength of healing fractures with dual energy Xray absorptiometry.

Dual energy xray absorptiometry was investigated as a method for evaluation of the strength of closed tibial fractures. In 40 goats, a closed midshaft fracture was created in the left tibia. The fractures were stabilized with an external fixator. After 2 weeks (n = 21) and after 4 weeks (n = 19), both tibias were explanted and, using dual energy xray absorptiometry, bone mineral density and bone mineral content were measured in a 1 cm region. With nondestructive bending tests, area ratio and stiffness index were determined and torsional strength and torsional stiffness were determined with a torsional test to failure. Linear regression analysis was used to calculate the squared correlation coefficients for the relations between dual energy xray absorptiometry and the outcome of the mechanical tests. The squared correlation coefficients for the relation between bone mineral density and torsional strength, torsional stiffness, and area ratio and stiffness index were 0.72, 0.76, 0.64, and 0.72, respectively. The squared correlation coefficients for the relation between bone mineral content and these mechanical parameters were 0.72, 0.77, 0.63, and 0.77, respectively. The results using dual energy xray absorptiometry indicate the strength of healing closed fractures. Additional research is required to investigate specific aspects of this technique.

Absorptiometry, Photon↗

Destination of debris during intramedullary reaming. An experimental study on sheep femurs.

This study was designed to further explain the better fracture healing in fractures treated with a reamed nail. It investigates the location and quantity of the reaming debris in an ex vivo animal model to test the autograft theory. In 10 cadaveric sheep femurs, a 5-mm semicircular gap was created at the midshaft. The medullary cavity was opened and the reaming debris that dropped from the gap during reaming and the debris from the proximal opening were collected and weighed separately. The mean harvest of reaming debris at the gap was 0.99 g +/- 0.12 g (24%) and from the proximal opening at the medullary cavity 3.08 g +/- 0.31 g (76%) (total 4.07 +/- 0.34 g). This study proves that a significant amount of reaming debris collects at an artificial fracture gap during reaming of the medullary cavity. This finding supports the theory of bone autografting.

Animals↗

New segmental long bone defect model in sheep: quantitative analysis of healing with dual energy x-ray absorptiometry.

An appropriate animal model is required for the study of treatments that enhance bone healing. A new segmental long bone defect model was developed for this purpose, and dual energy x-ray absorptiometry was used to quantify healing of this bone defect. In 15 sheep, a 3-cm segmental defect was created in the left tibia and fixed with an interlocking intramedullary nail. In seven animals, the defect was left empty for the assessment of the spontaneous healing response. In eight animals serving as a positive control, autologous bone grafting was performed. After 12 weeks, healing was evaluated with radiographs, a torsional test to failure, and dual energy x-ray absorptiometry. The mechanical test results were used for the assessment of unions and nonunions. Radiographic determination of nonunion was not reliably accomplished in this model. By means of dual energy x-ray absorptiometry, bone mineral density and content were measured in the middle of the defect. Bone mineral density was 91+/-7% (mean +/- SEM) and 72+/-6% that of the contralateral intact tibia in, respectively, the autologous bone-grafting and empty defect groups (p = 0.04). For bone mineral content, the values were, respectively, 117+/-18 and 82+/-9% (p = 0.07). Torsional strength and stiffness were also higher, although not significantly, in the group with autologous bone grafting than in that with the empty defect. Bone mineral density and content were closely related to the torsional properties (r2 ranged from 0.76 to 0.85, p < or = 0.0001). Because interlocking intramedullary nailing is a very common fixation method in patients, the newly developed segmental defect model has clinical relevance. The interlocking intramedullary nail provided adequate stability without implant failure. This model may be useful for the study of treatments that affect bone healing, and dual energy x-ray absorptiometry may be somewhat helpful in the analysis of healing of this bone defect.

Absorptiometry, Photon↗

Bone tissue response to biodegradable polymers used for intra medullary fracture fixation: a long-term in vivo study in sheep femora.

Since the degradability of the synthetic polymers used for fracture fixation is still unclear, a research project with biodegradable interlocking nails with a longterm implantation period has been started. In 21 female sheep a complete mid-shaft osteotomy of the left femur was performed to mimic a fracture of the femoral shaft. For the fixation, an intramedullary stainless-steel interlocking nail, a PLA rod or a PLA/PGA rod was used. After 30 months of implantation the histological results of these three materials were examined. In contrast to most reports the degradation rate of both polymers was much lower than the suggested ultimate period of two years. Even the tissue response was more pronounced than expected and this reaction can imply certain risks for repulsion. One can conclude that the volume quantity of polymeric implant in the bony tissue must be reduced if possible to avoid severe foreign body responses. The immunologic responses and the clinical consequences need more studies. The degradation behavior of the polymer is still not under control.

Animals↗

Myocardial contusion as a result of isolated sternal fractures: a fact or a myth?

Isolated sternal fractures are seen with an increasing frequency in traffic road accidents especially after the introduction of the seatbelt legislation. In most cases, the victims are young, otherwise healthy individuals. The medical records of all patients who were treated with a diagnosis of sternal fracture over the past 10 years were retrospectively reviewed. All patients with a radiologic diagnosis of sternal fracture were admitted for cardiac monitoring for at least 24 hours. ECG, determinations of cardiac enzyme levels CK (creatinephosphokinase) and CK-MB and evaluation by a cardiologist were routinely performed. An echocardiography was performed when indicated by the cardiologist. A total of 86 patients had sustained a sternal fracture during the 10-year study period. There were 39 males and 47 females with a mean age of 50 years (range 15-97 years). Serial 12-lead electrocardiograms, which were performed in 83 (97%) patients, revealed no information about myocardial contusion or cardiac arrhythmias with consequent therapy. In eight patients, a significant elevation in cardiac enzyme levels (elevation of CK-MB fraction above 10% of CK) was observed. All were normalized within 24 hours without development of any arrhythmias. Echocardiography was performed in 31 patients. In two patients, dyskinesia of the right ventricle (without enzyme elevations or arrhythmias) was observed. Within 24 hours these abnormalities resolved. The cardiac rhythm was monitored in 61 (71%) patients for a total of 1550 hours. No arrhythmias were observed. The cardiac enzyme studies, ECG and echocardiography revealed no consequent information about arrhythmias. In case of a sternal fracture, we recommend a chest X-ray to exclude other associated intrathoracic injuries. If no abnormalities are identified, admission to hospital is not necessary.

Accidents, Traffic↗

Randomised trial of glutamine-enriched enteral nutrition on infectious morbidity in patients with multiple trauma.

BACKGROUND: Infections are an important cause of morbidity and mortality in patients with multiple trauma. Studies in both animals and human beings have suggested that glutamine-enriched nutrition decreases the number of infections. METHODS: Patients with multiple trauma with an expected survival of more than 48 h, and who had an Injury Severity Score of 20 or more, were randomly allocated glutamine supplemented enteral nutrition or a balanced, isonitrogenous, isocaloric enteral-feeding regimen along with usual care. Each patient was assessed every 8 h for infection, the primary endpoint. Data were analysed both per protocol, which included enteral feeding for at least 5 days, and by intention to treat. FINDINGS: 72 patients were enrolled and 60 received enteral feeding (29 glutamine-supplemented) for at least 5 days. Five (17%) of 29 patients in the glutamine-supplemented group had pneumonia compared with 14 (45%) of 31 patients in the control group (p<0.02). Bacteraemia occurred in two (7%) patients in glutamine group and 13 (42%) in the control group (p<0.005). One patient in the glutamine group had sepsis compared with eight (26%) patients in the control group (p<0.02). INTERPRETATION: There was a low frequency of pneumonia, sepsis, and bacteraemia in patients with multiple trauma who received glutamine-supplemented enteral nutrition. Larger studies are needed to investigate whether glutamine-supplemented enteral nutrition reduces mortality.

Adult↗

[Bone transplantation and bone replacement materials].

There is a growing need for immediately available material with appropriate qualities for reconstruction of large bone defects. Autologous spongy bone grafts are optimal as to biocompatibility, but are in short supply. Allogenic and xenogenic bone grafts evoke an immunological reaction after implantation and are not biocompatible. In the last thirty years ceramic implants and composites have been developed for bone substitution. New calcium phosphate bone substitutes undergo processes of resorption and precipitation of carbonate apatite that play a part in formation of new bone. These materials are easy to use because of their pastelike consistence. Resorption properties are influenced by particle size, crystallinity and composition. So far, no serious adverse reactions were reported. More clinical experience is necessary especially with composites and combinations with antibiotics, bone growth factors and collagen, to specify the place of these modern calcium phosphates in bone replacement and bone substitution.

Apatites↗

[Resorbable rods and screws for fixation of ankle fractures. A randomized clinical prospective study].

A prospective randomized clinical trial was performed to evaluate the use of self-reinforced absorbable composites (Biofix) in the fixation of ankle fractures. The aim of this study was to demonstrate that fixation with Biofix rods and screws is as good as the standard A.O. fixation. The benefits of Biofix rods and screws are: a reduction in costs since no secondary operation is needed, prevention of stress-shielding and thereby diminishing the risk of bone porosity. Patients aged between 16 and 75 years old with closed, non-comminuted fractures of the lateral and/or medial malleolus and dislocation of the fracture fragments greater than 2 mm were included in the study. 22 patients were treated with Biofix rods and screws and the control group of 19 patients with a standard technique. After 3, 6 and 12 months, rontgenograms were taken. At the same time functional results were evaluated following the criteria of Olerud and Molander. Two patients were withdrawn from the trial for non-medical reasons. 22 patients (12 from the Biofix group, 10 from the AO group) operated two or more years ago were contacted to see if any complications had occurred since they were last seen. In 4 cases a Biofix screw broke down just beneath the head during insertion. This did not result in an insufficient fixation of the fracture. There were no early post-operative complications. The functional and rontgenological results in both groups were equal. In three cases a sterile sinus developed at the site of screw insertion. Biofix rods and screws, made of polylactic acid, are a good alternative for the fixation of fractures of the ankle. The use of resorbable fracture fixation material has the advantage that a second operation to remove osteosynthesis material is not necessary. The long term results are good. There is, however, a possibility of development of tissue reaction to the resorbable material.

Adolescent↗

Quantification of fracture healing with three-dimensional computed tomography.

Quantitative methods are necessary for an objective evaluation of fracture healing. Three-dimensional computed tomography (CT) for the measurement of callus volume and density could be such a method and was investigated in an animal model. In 23 goats a closed tibial fracture was created and stabilized with a cast. The animals were killed at 2, 4 and 6 weeks for radiographical, CT and biomechanical analysis. From the CT scans a three-dimensional reconstruction of the callus was made to measure its volume and mean density. At 2 weeks the callus volume had already reached its maximum. In contrast, callus density, torsional strength and torsional stiffness increased over time (P < 0.0001, analysis of variance, ANOVA). Multiple regression analysis showed that the callus volume was not related to the torsional properties. However, callus density was a significant explanatory variable for both torsional strength (R2 = 0.72, P < 0.0001) and torsional stiffness (R2 = 0.82, P < 0.0001). Therefore, callus density as measured by three-dimensional CT is a predictor of the extent of fracture consolidation. CT with three-dimensional reconstruction of the callus seems a valid technique for the quantification of fracture healing.

Analysis of Variance↗

Representative assessment of long bone shaft biomechanical properties: an optimized testing method.

Whole bone bending tests are commonly used in mechanical evaluation of long bones. Reliable information about the midshaft can only be obtained if the bending moment is uniformly distributed along the shaft, and if the distribution of the bending stress is not adversely influenced by rigid clamping of the bone ends. A testing device was developed to determine bending stiffness of long bones in 24 directions, perpendicular to the bone axis. For optimal distribution of bending moment and stress, four-point bending was performed, and bone ends were simply supported, not rigidly clamped. The method was validated by repeated testing of a stainless steel rod, and a sheep femur. Left-right ratios were assessed twice in 2 groups of 5 sheep: one control group, and one group in which the left femur was stabilized with a stainless steel interlocking nail for 2.5 yr, after a midshaft osteotomy. Test results obtained with the steel rod reproducibly were close to predicted values. Measurements with the sheep femurs were reproducible and precise for 3 of the 4 parameters of the bending test. Stiffness parameters were significantly higher in the operated sheep than in the control group. We conclude that the method described here provides accurate and reproducible information, which is representative for the long bone shaft.

Animals↗

Biodegradable interlocking nails for fracture fixation.

Serious problems such as stress shielding, allergic reactions, and corrosion are associated with the use of metallic fracture fixation devices in fractured long bones. Metal implants often are removed during a second retrieval operation after fracture healing has completed. A biocompatible implant that degrades slowly during implantation would obviate the need for a second operation and save the patient from considerable physical, psychologic, and financial discomfort. The biodegradable implant must provide the fractured limb sufficient support for a certain time, allowing early loading. A gradual transfer of load from the biodegradable implant to the bone would result in a better product of bone healing and avoid stress shielding. In an animal model using adult sheep, two types of biodegradable polymer interlocking nails were tested in comparison with a stainless steel interlocking nail. Fracture healing, mechanical properties of the bones, degradation behavior in vivo and in vitro, and tissue response were monitored during a 2 1/2-year followup study. To detect shifts in acid base relations caused by the release of acid compounds, pH measurements were performed. Fracture healing was unimpaired, and the mechanical test results of all three groups were excellent. Histologic analysis showed a mild inflammatory response, but no pH shifts were observed. The results of this study justify additional research on these promising materials.

Absorbable Implants↗