PubMed Health⌕ Search

Biomedical subjects

H J Issaq

Publications and source records attributed to H J Issaq.

At least 19 recordsLinked to original sources

A comparison of microLC/electrospray ionization-MS and GC/MS for the measurement of stable isotope enrichment from a [2H2]-glucose metabolic probe in T-cell genomic DNA.

Measurement of the proliferation of lymphocytes and other high-turnover cell populations in vivo can be accomplished through the incorporation of an isotopically labeled DNA precursor into actively dividing cells and the subsequent determination of the isotope enrichment in the isolated genomic DNA from selected cell populations. Two published gas chromatography/mass spectrometry (GC/MS) methods were successfully modified by our laboratory whereby a postinjection methylation reaction, rather than silylation or acetylation, was used to form a volatile derivative of deoxyadenosine (dA). We also developed a second robust microcapillary liquid chromatography-electrospray ionization (microLC-ESI)/MS method that is faster and more sensitive than the GC/MS method and does not require sample derivatization. Following administration of [6,6-(2)H(2)]-glucose to human immunodeficiency virus-infected patients, peripheral blood was drawn; cells were obtained by lymphapheresis and fractionated. DNA was isolated from the desired cell subtypes and enzymatically hydrolyzed to the free deoxyribonucleosides. The digest was analyzed using both capillary GC/MS and microLC/ESI-MS to measure the levels of the dA and [(2)H(2)]-dA or their reaction products. Sample enrichments were calculated by comparison to standard curves prepared from dA and [(2)H(2)]-dA. The microLC/ESI-MS method required fewer cells, less sample preparation, shorter analysis times, and a single calibration curve. Overall, the microLC/ESI-MS method is superior to the GC/MS method in terms of precision and accuracy, while providing a 4-fold increase in sensitivity (from 20 pmol at 0.2% [(2)H(2)]-dA enrichment to 5 pmol at 0.1% [(2)H(2)]-dA enrichment).

Chromatography, Liquid↗

Modulation of HIV-like particle assembly in vitro by inositol phosphates.

HIV-1 Gag protein assembles into 100- to 120-nm diameter particles in mammalian cells. Recombinant HIV-1 Gag protein assembles in a fully defined system in vitro into particles that are only 25-30 nm in diameter and that differ significantly in other respects from authentic particles. However, particles with the size and other properties of authentic virions were obtained in vitro by addition of inositol phosphates or phosphatidylinsitol phosphates to the assembly system. Thus, the interactions between HIV-1 Gag protein molecules are altered by binding of inositol derivatives; this binding is apparently essential for normal HIV-1 particle assembly. This requirement is not seen in a deleted Gag protein lacking residues 16-99 within the matrix domain.

Amino Acid Sequence↗

Peptide mapping by capillary zone electrophoresis: how close is theoretical simulation to experimental determination.

A multi-variable computer model is presented for the prediction of the electrophoretic mobilities of peptides at pH 2.5 from known physico-chemical constants of their amino acid residues. The model is empirical and does not claim any theoretical dependencies; however, the results suggest that, at least at this pH, peptides may be theoretically represented as classical polymers of freely joined amino acid residues of unequal sizes. The model assumes that the electrophoretic mobility can be represented by a product of three functions that return the contributions of peptide charge, length and width, respectively to the mobility. The model relies on accurate experimental determination of the electrophoretic mobilities of a diverse set of peptides, by capillary zone electrophoresis (CZE), at 22 degrees C, with a 50 mM phosphate buffer, at pH 2.5. The electrophoretic mobilities of a basis set of 102 peptides that varied in charge from 0.65 to 16 and in size from two to 42 amino acid residues were accurately measured at these fixed experimental conditions using a stable 10% linear polyacrylamide-coated column. Data from this basis set was used to derive the peptide charge, length, and width functions respectively. The main purpose of this endeavor is to use the model for the prediction of peptide mobilities at pH 2.5, and for simulation of CZE peptide maps of protein digests. Excellent agreement was obtained between predicted and experimental electrophoretic mobilities for all categories of peptides, including the highly charged and the hydrophobic. To illustrate the utility of this model in protein studies it was used to simulate theoretical peptide maps of the digests of glucagon and horse cytochrome c. The resulting maps were compared and contrasted with their experimental counterparts. The potential of this approach and its limitations are discussed.

Amino Acid Sequence↗

Multidimensional high performance liquid chromatography--capillary electrophoresis separation of a protein digest: an update.

The trypsin digest of a mixture of two proteins, namely cytochrome c and myoglobin, was first separated in the first dimension by high-performance liquid chromatography (HPLC). Fractions from the HPLC were collected every 30s with the aid of a fraction collector into a 96-well microtiter plate. After concentration, all the collected fractions were analyzed simultaneaosly in the second dimension by a 96-array capillary electrophoresis system. The labeled peptides were detected by laser-induced fluorescence. An internal standard, allura red, was added to all the fractions, prior to capillary electrophoretic analysis. The internal standard serves two functions, migration time correction and signal intensity correction. The data are presented in two different formats, as an electropherogram of all the fractions and in a two-dimensional (2-D) format. The 2-D plot of the data shows the density of each spot, which corresponds to the concentration of the migrating peptides. The total experimental time for the HPLC and capillary electrophoretic analyses ist less than 1 h, which ist much faster than using 2-D slab-gel electrophoresis or single-capillary capillary electrophoresis.

Chromatography, High Pressure Liquid↗

The role of separation science in proteomics research.

In the last few years there has been an increased effort into the separation, quantification and identification of all proteins in a cell or tissue. This is a review of the role gel electrophoresis, high performance liquid chromatography (HPLC), and capillary electrophoresis (CE) play in proteomics research. The capabilities and limitations of each separation technique have been pointed out. Instrumental strategies for the resolution of cell proteins which are based on efficient separation employing either a single high-resolution procedure or a multidimensional approach on-line or off-line, and a mass spectrometer for protein identification have been reviewed. A comparison of the advantages of multi-dimensional separations such as two-dimensional polyacrylamide gel electrophoresis, HPLC-HPLC, and HPLC-CE to the separation of cell and tissue proteins are discussed. Also, a discussion of novel approaches to protein concentration, separation, detection, and quantification is given.

Chromatography, High Pressure Liquid↗

Nicotine metabolism and CYP2D6 phenotype in smokers.

We tested the hypothesis that the polymorphic enzyme CYP2D6 is related to nicotine metabolism in 261 healthy subjects enrolling in a smoking cessation clinic. Subjects completed a questionnaire, were given dextromethorphan, and contributed a urine and blood sample. The CYP2D6 phenotype (based on a determination of dextromethorphan and metabolites in an aliquot of overnight urine) and genotype (based on characterization of CYP2D6 variant alleles by a PCR-based method on a subset) were determined. Seventeen poor metabolizers (6.5%) were observed among 261 phenotyped smokers. Nicotine and it chief metabolites, cotinine and trans-3'-hydroxycotinine were measured in the urine and adjusted for pH. All of the nicotine metabolite levels were significantly related to usual and recent smoking. Neither levels of smoking nor nicotine metabolites overall exhibited a relationship to the CYP2D6-deficient metabolizer phenotype. The ratio of nicotine:cotinine + trans-3'-hydroxycotinine, stratified by time since the last cigarette, was unrelated to gender, age, education, race (white/African American), recent alcohol or caffeine consumption, or smoking practices. Subjects in either the lowest quintile or decile metabolic ratio (ultrametabolizers) exhibited a significantly lower nicotine:cotinine + trans-3'-hydroxycotinine ratio after adjustment for recent smoking, pH, and other factors. These data suggest that the polymorphic CYP2D6 gene is not a major contributor to nicotine metabolism in tobacco smokers but may influence the disposition of nicotine in the small subset of the population who are CYP2D6 ultrametabolizers.

Adult↗

Effect of temperature on the separation of DNA fragments by high-performance liquid chromatography and capillary electrophoresis: a comparative study.

This study investigates the effect of experimental temperature on the separation of DNA fragments, 21-587 bp, by both high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The results show that the temperature plays an important role in the HPLC separation of DNA fragments. The optimum temperature was found to be between 40 and 50 degrees C for HPLC, while 25 degrees C was the optimum temperature for the CE separation. Also, although CE migration times became shorter, efficiency and resolution decreased with an increase in temperature from 25 to 50 degrees C, but the separation was not significantly affected. Also, the optimum HPLC temperature might be different depending on the fragment sizes to be resolved.

Chromatography, High Pressure Liquid↗

A decade of capillary electrophoresis.

Since the introduction of the first commercial capillary electrophoresis (CE) instrument a decade ago, CE applications have become widespread. Today, CE is a versatile analytical technique which is successfully used for the separation of small ions, neutral molecules, and large biomolecules and for the study of physicochemical parameters. It is being utilized in widely different fields, such as analytical chemistry, forensic chemistry, clinical chemistry, organic chemistry, natural products, pharmaceutical industry, chiral separations, molecular biology, and others. It is not only used as a separation technique but to answer physicochemical questions. In this review, we will discuss different modes of CE such as capillary zone electrophoresis, micellar electrokinetic chromatography, capillary gel electrophoresis, capillary isoelectric focusing, and capillary electrochromatography, and will comment on the future direction of CE, including array capillary electrophoresis and array microchip separations.

Amino Acids↗

Solid-state UV laser-induced fluorescence detection in capillary electrophoresis.

Two solid-state UV lasers were applied to the laser-induced fluorescence (LIF) detection of various groups of compounds after separation by capillary electrophoresis. These lasers are thermoelectric-cooled, highly compact, and inexpensive. Such lasers provide few mW of quasi-continuous wave (CW) power which are sufficient and stable for LIF detection. Native fluorescence detection of tryptophan-containing proteins and peptides and related indoles was achieved at the nM level with the laser operating at 266 nm. Detection of fluorescamine-labeled amino acids and peptides was also possible at the nM level with the laser operating at 355 nm. Amino acids at a concentration as low as 10 ng/mL could be labeled with fluorescamine. Solid-state UV-LIF detection of the tryptic digest of cytochrome c after fluorescamine derivatization was demonstrated.

Amino Acids↗

Peptide mobility and peptide mapping in capillary zone electrophoresis. Experimental determination and theoretical simulation.

The electrophoretic mobilities of 58 peptides that varied in size from 2 to 39 amino acids and varied in charge from 0.65 to 7.82 are presented. The measurements were conducted at 22 degrees C using a 10% linear polyacrylamide-coated column and a 50 mM phosphate buffer at pH 2.5. Excellent separation of peptides and highly reliable peptide maps of protein digests are routinely obtained using these experimental conditions. The electrophoretic data were used to test existing theoretical models that correlate electrophoretic mobility with physical parameters. The results indicate that the Offord model that correlates electrophoretic mobility with the charge-to-size parameter q/M2/3 offers the best fit of our reliable experimental data. Furthermore, we also obtained the capillary zone electrophoretic profile of the endoproteinase Lys-C digests of a peptide sequencing standard, melittin, and horse myoglobin under the same experimental conditions as described above. The resulting peptide maps were compared with corresponding theoretical simulation.

Amino Acid Sequence↗

A simple two-dimensional high performance liquid chromatography/high performance capillary electrophoresis set-up for the separation of complex mixtures.

A two-dimensional high performance liquid chromatography/capillary electrophoresis (HPLC/CE) instrumental set-up was assembled from commercially available equipment. Fractions of the effluent from the HPLC system are collected into microtiter plates with a microfraction collector. The fractions are then dried under vacuum at room temperature, reconstituted, and analyzed by capillary zone electrophoresis (CZE). This method allows the collection of samples by time, drops, or external signal (peaks). Any size or type of HPLC or CE column can be used with no limitation on the amount of sample injected into the HPLC. Any CE detection, laser-induced fluorescence (LIF), mass spectrometry (MS), ultraviolet (UV) or other, can be used. This set-up is practical, simple, robust and allows the separation of complex mixtures. Preliminary results show the utility of this system for the analysis of protein digest.

Chromatography, High Pressure Liquid↗

Capillary electrophoresis of natural products-II.

Capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) were used for the separation of widely different compounds from natural materials including compounds from tea, acids from different matrices, flavonoids and alkaloids, toxins and toxicological compounds, proteins and polypeptides, biogenic amines, phenolic compounds in alcoholic beverages, Chinese medicinal drugs, compounds in cells and cell extracts, and miscellaneous other applications. A section dealing with recent reviews related to natural products is also included.

Alkaloids↗

Capillary electrophoresis analysis of isomeric truxillines and other high molecular weight impurities in illicit cocaine.

The analysis of by-products and impurities in illicit cocaine, including the isomeric truxillines, is important for derivation of both strategic and tactical intelligence. In the present study, various capillary electrophoresis techniques were investigated for this purpose. The use of the anionic beta-cyclodextrin sulfobutyl ether IV as a run buffer additive at pH 8.6 gave a good separation of the truxillines and similar high molecular weight impurities in less than eight minutes. These impurities were first isolated from the bulk cocaine matrix using liquid-liquid extraction and size-exclusion high performance liquid chromatography. There was a red shift in the UV spectra obtained for the truxillines using photodiode array (PDA) UV detection during CE analysis. This anomalous behavior is attributed to photo-degradation of the truxillines during the PDA-UV irradiation process. Laser-induced fluorescence detection using a UV krypton/fluoride laser provided greater selectivity and sensitivity versus UV detection for certain uncharacterized high molecular weight impurities.

Cocaine↗

Metabolic conversion of 1,1-dichloro-2,2-bis(p-chlorophenyl)ethane (DDD) to 1,1-dichloro-2,2-bis(p-chlorophenyl)ethylene (DDE) in the male F344/NCr Rat.

1,1-Dichloro-2,2-bis(p-chlorophenyl)ethane (DDD) and 1,1-dichloro-2, 2-bis(p-chlorophenyl)ethylene (DDE) levels were measured by capillary gas chromatography with electron capture detection in liver and blood serum of male F344/NCr rats exposed for 2 weeks to DDD at dietary concentrations ranging from 8.51 ppm to 2,000 ppm. DDD burdens in serum ranged from <0.006 microM (limit of detection) in control rats to 1.1 microM in the rats fed DDD at 2,000 ppm. The corresponding liver burdens in these animals ranged from <0.006 micromol/kg liver (controls) to 11 micromol/kg liver in rats fed DDD at 2,000 ppm. Levels of DDE in serum or liver were undetectable (<0. 006 microM in serum; <0.006 micromol/kg liver) in rats fed control diet or diet containing 8.51 or 25.5 ppm DDD. The liver and serum burdens of DDE increased with dietary DDD concentration, reaching a maximum of 0.53 microM in serum and 4.7 micromol/kg liver in rats fed 2,000 ppm DDD. As a percentage of total DDD equivalents detected in liver or serum, the DDE burdens increased to a maximum of 36% and 31% in the serum and liver, respectively, of rats fed 689 ppm DDD. The possibility that the DDE might have been generated artifactually in the diet prior to administration to the rats was ruled out by analysis with capillary gas chromatography of the diet containing 2, 000 ppm DDD. The identification of DDE as a metabolite in liver extracts of rats fed 2,000 ppm DDD was confirmed with GC-MS. The results confirmed the presence of DDE as a metabolite of DDD.

Animal Feed↗

Electrokinetic chromatography without electroosmotic flow.

This review summarizes the various aspects of conducting electrokinetic chromatography in coated columns with suppressed electroosmotic flow. The specific features of the technique will be presented and the potential applications explored. The equations of migration, resolution and zone spreading for neutral solutes will be presented, compared, and contrasted with those of conventional electrokinetic chromatography in bare-silica columns. The principle of separation is the same in electrokinetic chromatography with or without electroosmotic flow; however, there are many significant differences that will be highlighted.

Chromatography, Liquid↗

Uptake and tissue distribution of chromium(III) in mice after a single intraperitoneal or subcutaneous administration.

The tissue levels of chromium were followed after single intraperitoneal or subcutaneous injection of 1 mmol CrCl3/kg body wt. in Swiss male mice. Blood levels were similar after both treatment modes, with half-lives of 31-41 h. Organs not directly exposed by i.p. treatment contained similar amounts in the two groups, with kidneys > lungs > heart > brain. However, after i.p. treatment peritoneal organs (liver, spleen, pancreas and testis) had 40- to 200-fold more chromium compared with s.c. Assay of subsurface liver tissue and of testes removed via the scrotum indicated infiltration of the organs, rather than surface adsorption, of peritoneal chromium. Relative chromium concentrations after i.p. treatment were liver > pancreas = spleen > testis and after s.c. liver > spleen > testis > pancreas. Thus, s.c. treatment with CrCl3 is as effective as i.p. in terms of absorption into the blood. Treatment i.p., leading to direct uptake into peritoneal organs, is an effective way to deliver high chromium doses to these organs, but does not model likely human exposure.

Animals↗