PubMed HealthSearch

Biomedical subjects

H J Marais

Publications and source records attributed to H J Marais.

3 recordsLinked to original sources

Isolated atrial infarction in a patients with single vessel disease of the sinus node artery.

Atrial infarction is found in approximately 17 percent of autopsy-proven cases of myocardial infarction, but is a frequently missed clinical diagnosis. The antemortem diagnosis of atrial infarction occurring in the absence of ventricular infarction has not been previously reported. We present a patient with ischemic chest discomfort associated with paroxysmal atrial fibrillation. Electrocardiographic and enzymatic changes were consistent with atrial infarction. Cardiac catheterization demonstrated single vessel critical stenosis at the origin of the sinus node artery. Combined atrial and ventricular infarction occurs frequently and should be considered in the setting of paroxysmal supraventricular arrhythmias occurring early in the course of ventricular myocardial infarction. Lone atrial infarction is a rare but distinct clinical entity. The tetrad of typical ischemic chest discomfort, paroxysmal supraventricular arrhythmia, P-Ta segment shifts, and elevated cardiac enzyme levels without evidence for ventricular infarction strongly suggests isolated atrial infarction.

Aged

Coronary angioscopy during cardiac catheterization.

Coronary angioscopy should permit direct inspection of the luminal cross section and identification of disease. The feasibility of introducing a 5F Olympus Ultrathin fiberscope into the obstructed right coronary artery in five patients after routine cardiac catheterization by the brachial approach was therefore tested. An 8.3F USCI woven Dacron angioplasty guiding catheter was modified to enlarge its lumen. After engaging the right coronary ostium with the catheter, an attempt was made to pass the angioscope coaxially to the tip of the catheter. Visualization of the coronary lumen was then achieved in three patients by manually injecting 5 to 10 cc of normal saline solution through the guiding catheter at 2 to 3 cc/s. White atheromatous plaque could be seen near the site of obstruction in each case. In two patients, a lack of sufficient flexibility in the distal 2 cm of the angioscope prevented passage to the catheter tip. Preliminary experience with a videoendoscopic system suggests that this monitoring technique is essential for the adequate performance of angioscopy and for recording dynamic changes during blood displacement. Geometric distortion of the image and nonlinearities in magnification and light reflex with a decreasing lens to object distance make quantitative evaluation of the lumen difficult. Lack of an angulation system further contributes to this problem and, more importantly, restricts passage of the angioscope to the proximal 1 to 2 cm segments of coronary arteries. Although coronary angioscopy may have research and clinical applications in the future, these technical problems should first be addressed.

Angiography