PubMed Health⌕ Search

Biomedical subjects

H J Rice

Publications and source records attributed to H J Rice.

5 recordsLinked to original sources

A dynamic and harmonic damped finite element analysis model of stapedotomy.

This study was undertaken in an attempt to better understand the mechanics of sound transmission at the footplate following stapedotomy. The insertion of a Teflon (polytetrafluoroethylene) stapes prosthesis introduces new constraints within the reconstructed ossicular chain which have an effect on the normal vibration patterns of the tympanic membrane. In a finite element model of the ear, constraints have been reproduced as a series of spring constants in the incus/prosthesis/footplate interfaces incorporating damping to simulate the impedance of the inner ear. At zero damping, the frequency response at the pseudo stapes footplate exhibit several maxima and minima between 800 Hz and 2.5 Hz. At higher damping values, these maxima and minima become smoothened out with two or three naturals occurring over the same frequency range. Severe ankylosis of a diseased footplate is reproduced by over-damped conditions. The umbo, incus and stapes footplate vibrate in phase with similar frequencies at light damping levels. The movement of the prosthesis at the pseudo-footplate can be large in the out of plane axis of the ossicular chain, unless sufficient support is provided at the reconstructed footplate. Clinically, this would suggest the vein graft interposed between the piston and stapedotomy hole should endow resistance and elasticity to the system.

Acoustics↗

An experimental technique for determining middle ear impedance.

A two-microphone technique was used to determine the middle ear impedance of a live subject. The procedure involved the application of standing wave tube theory and the assumption that the ear canal behaves like an homogeneous cylinder with plane acoustic wave propagation up to a certain frequency--2 kHz for the current analysis. During experimentation the subject lay on a bench with his head braced against a wooden fixture. Acoustic pressures were recorded from the ear canal by the use of a spectrum analyser and probe microphones with flexible tips. Resultant impedance curves show middle ear natural frequencies at 831 Hz and 1,970 Hz with high levels of damping. The reactive impedance curves show the influence of stiffness and ossicular mass on middle ear sound transmission. An advantage of the approach is that using features of the recorded data it is possible to calculate the effective probe tip to eardrum distance required for the calculation of the middle ear impedance. The two-microphone technique appears to be a promising tool for assessing healthy and diseased middle ear function.

Acoustic Impedance Tests↗

Development of a finite element model of the middle ear.

A representative finite element model of the healthy ear is developed commencing with a description of the decoupled isotropic tympanic membrane. This model was shown to vibrate in a manner similar to that found both numerically (1, 2) and experimentally (8). The introduction of a fibre system into the membrane matrix significantly altered the modes of vibration. The first mode "remains as a piston like movement as for the isotropic membrane. However, higher modes show a simpler vibration pattern similar to the second mode but with a varying axis of movement and lower amplitudes. The introduction of a malleus and incus does not change the natural frequencies or mode shapes of the membrane for certain support conditions. When constraints are imposed along the ossicular chain by simulation of a cochlear impedance term then significantly altered modes can occur. More recently a revised model of the ear has been developed by the inclusion of the outer ear canal. This discretisation uses geometries extracted from a Nuclear Magnetic resonance scan of a healthy subject and a crude inner ear model using stiffness parameters ultimately fixed through a parameter tuning process. The subsequently tuned model showed behaviour consistent with previous findings and should provide a good basis for subsequent modelling of diseased ears and assessment of the performance of middle ear prostheses.

Biomechanical Phenomena↗

Vibro-acoustic modelling of the outer and middle ear using the finite-element method.

In this study, a computer-based method called finite-element analysis is used to predict the forced-frequency response of the ear, with and without an ossicular replacement prosthesis (PORP 0362, Xomed Surgical Products). The method allows visualisation of the dynamical behaviour of the tympanic membrane (TM) and of the ossicles. The finite-element model is fully three-dimensional and includes both ligaments and muscles, and accounts for damping caused by the TM, ligaments, incudostapedial joint and the fluids of the inner ear. For validation, comparison is made with experimental measurements of umbo displacement taken from the literature. The translation and rotation (both anterior-posterior and inferior-superior) of the stapedial footplate are investigated. It is predicted that the translatory motion of the footplate decreases with increasing frequency, except when the frequency of the acoustic signal matches the natural frequencies of the ossicular chain or outer ear canal. The tilting motion of the stapedial footplate is also predicted to depend on frequency of excitation. The presence of a prosthesis changes the dynamical response considerably by shifting the natural frequencies of the ossicular chain. Ratios of stapes motion with and without the prostheses are plotted as a function of frequency allowing this effect to be clearly observed.

Ear, External↗