PubMed Health⌕ Search

Biomedical subjects

H Köster

Publications and source records attributed to H Köster.

At least 37 records · Page 2Linked to original sources

Identification of apolipoprotein E polymorphisms using temperature cycled primer oligo base extension and mass spectrometry.

The isothermal Primer Oligo Base Extension (PROBE) reaction combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for diagnostic product detection as recently introduced by our group is modified to incorporate temperature cycling during the primer extension step, resulting in enhanced levels of diagnostic product generation. Utilizing temperature cycled PROBE, the identities of two apolipoprotein E polymorphisms (codons 112 and 158) for differentiation of epsilon 2/epsilon 3, epsilon 3/epsilon 3, epsilon 3/epsilon 4, and epsilon 4/epsilon 4 genotypes were simultaneously determined. Primers specific for each site are extended by a series of bases unique to the identity of that variable site, producing low mass diagnostic products (M(r) < 9000) highly amenable to detection by mass spectrometry. The temperature cycled PROBE method has yielded unambiguous and correct diagnoses for all samples tested thus far. The increased amount of diagnostic product generated per primer by the cycling method makes possible faster spectrum acquisition due to the increased signal intensity, critical for future automated measurement of such samples.

Apolipoproteins E↗

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the detection of polymerase chain reaction products containing 7-deazapurine moieties.

Double-stranded DNA fragments of different length with and without the incorporation of 7-deazapurine deoxynucleotides have been prepared via the polymerase chain reaction (PCR) using exo(-)Pseudococcus furiosus DNA polymerase, unmodified primers, and c7-dATP and c7-dGTP as the only purine triphosphates. In spite of the presence of some unmodified purine moieties due to the primers, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry revealed remarkable differences between the modified and unmodified DNA fragments. The incorporation of 7-deazapurine nucleotides resulted in a significant reduction of fragmentation and therefore in increased signal intensities and higher mass resolution. The molecular weights could be determined with an accuracy of up to 0.03%. Mass resolution was sufficient to resolve the (M + H)+ signals of the two single strands of a 7-deazapurine-containing 99-base-pair DNA duplex. Thus, MALDI-TOF mass spectrometry offers a very fast and accurate way to detect and analyze short PCR products sufficient in length for many diagnostic applications without gel electrophoresis and labeling.

Autoradiography↗

High-resolution MALDI Fourier transform mass spectrometry of oligonucleotides.

The matrix-assisted laser desorption/ionization (MALDI) method has been used with an external ion source Fourier transform mass spectrometer (FIMS) to analyze single-stranded, mixed-base oligomers of DNA. It is demonstrated that ultrahigh mass resolution (830 000 fwhm) can be achieved for small oligomers, and high resolution (136 000 fwhm) can be achieved for a 25-mer at m/z 7634. MALDI-FTMS can clearly separate the molecular ion peaks from analyte-matrix adduct peaks and alkali metal-containing species that result from replacement of hydrogen ions with sodium or potassium ions at multiple sites along the phosphate backbone. Previous MALDI-FTMS studies of oligonucleotides had two limitations: (1) low sensitivity due to difficulty in trapping the high kinetic energy ions made by the laser and (2) fragmentation of the ions due to the long delay (tens to hundreds of milliseconds) between their formation and detection. Both of these problems are alleviated in the present study. With the external ion source FTMS instrument, ions made by MALDI are injected at low energy into the analyzer cell by a rf-only quadrupole ion guide, captured by gating the voltage on the trapping plates, and cooled by a 0.5-s pulse of argon gas. Under these conditions, fragmentation is minimized, and DNA ions can be trapped in the FTMS analyzer cell for greater than 50 s. Sensitivity is also improved, as demonstrated by detection of 1 pmol of a single-stranded, mixed-base 20-mer of DNA, with a signal-to-noise ratio greater than 20:1.

Base Sequence↗

Analysis of ligase chain reaction products via matrix-assisted laser desorption/ionization time-of-flight-mass spectrometry.

A rapid and accurate detection of ligation products generated in ligase chain reactions (LCR) by using matrix-assisted laser desorption/ionization time-of-flight-mass spectrometry (MALDI-TOF-MS) is reported. LCR with Pfu DNA ligase was performed with a wild-type template and a template carrying a single point mutation within the Escherichia coli lacI gene as a model system. Starting from about 1 fmol of template DNA the ligation product generated in the positive reactions was analyzed with HPLC and MALDI-TOF-MS, whereby the need of proper sample purification prior to mass spectrometric analysis was demonstrated. A purification procedure with a high potential for automation using streptavidin-coated magnetic particles and ultrafiltration was introduced. Plasmid DNA and short single-stranded oligonucleotides have been used as template. A point mutation could be discriminated from the wild-type template due to the absence or presence of ligation product. This approach allows the rapid-specific detection of template DNA in femtomole amounts and moreover can distinguish between sequence variations in DNA molecules down to point mutations without the need for labeling, gel electrophoresis, membrane transfer, or hybridization procedures.

Base Sequence↗

Detection of hepatitis B virus DNA in serum samples via nested PCR and MALDI-TOF mass spectrometry.

In a blind study, nested polymerase chain reaction (PCR) was performed with control DNA and DNA preparations from serum samples of six patients. The detection limit was determined to be 100 molecules of template in 1 ml of serum. Hepatitis B virus (HBV) related products of nested PCR were purified by ultrafiltration and immobilisation on streptavidin coated magnetic beads. The immobilized PCR products were denatured from the beads and analyzed via matrix assisted laser desorption/ionisation time-of-flight (MALDI-TOF) mass spectrometry. The results of MALDI-TOF MS analysis were in agreement with the results obtained by polyacrylamide gel electrophoresis (PAGE) and with the data obtained by serological analysis. The detection strategy introduced here has a high potential for automation and represents a fast and reliable method of detection for HBV DNA in serum without the need for time consuming gel electrophoresis and labeling or hybridization procedures.

DNA, Viral↗

A strategy for rapid and efficient DNA sequencing by mass spectrometry.

Two methods of solid-phase Sanger DNA sequencing followed by detection with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry are demonstrated. In one method, sequencing ladders generated on an immobilized synthetic template were resolved up to the 63-mer including the primer. Detection sensitivity and resolution were sufficient for sequence analysis in the given range. This approach is particularly suitable for comparative (diagnostic) DNA sequencing. A second method that has the potential for high throughput de novo DNA sequencing is also presented; it uses immobilized duplex probes with five-base single-stranded overhangs to capture an unknown DNA template serving as primers for Sanger DNA sequencing. The power of mass spectrometry is demonstrated not only by its very high speed, but also by its ability to identify sequences that are not readable using gel electrophoresis.

Base Sequence↗

Efficient preparation of short DNA sequence ladders potentially suitable for MALDI-TOF DNA sequencing.

Duplex probes with five-base single-stranded overhangs were developed for positional sequencing by hybridization [Broude et al., Proc Natl Acad Sci USA 91:3072-3076, 1994]. The partially duplex probes can be employed to capture single-stranded oligonucleotide targets and form primer-template complexes. Recently we showed that partially duplex probes can prime Sanger sequencing reactions on immobilized, but non-ligated long single-stranded targets (approximately 500 nucleotide) [Fu et al., Proc Natl Acad Sci, in press]. Here immobilized, non-ligated partially duplex probes were used to capture and sequence short single-stranded targets. This strategy is capable of rapidly preparing large numbers of samples for future mass spectrometric DNA sequencing.

Base Sequence↗

A DNA sequencing strategy that requires only five bases of known terminal sequence for priming.

We have previously reported an enhanced version of sequencing by hybridization (SBH), termed positional SBH (PSBH). PSBH uses partially duplex probes containing single-stranded 3' overhangs, instead of simple single-stranded probes. Stacking interactions between the duplex probe and a single-stranded target allow us to reduce the probe sizes required to 5-base single-stranded overhangs. Here we demonstrate the use of PSBH to capture relatively long single-stranded DNA targets and perform standard solid-state Sanger sequencing on these primer-template complexes without ligation. Our results indicate that only 5 bases of known terminal sequence are required for priming. In addition, the partially duplex probes have the ability to capture their specific target from a mixture of five single-stranded targets with different 3'-terminal sequences. This indicates the potential utility of the PSBH approach to sequence mixtures of DNA targets without prior purification.

Base Sequence↗

A filtration method for plasmid isolation using microtiter filter plates.

A method for the simultaneous isolation of plasmid DNA from as many as 96 Escherichia coli clones in less than 2 h is described. It is based on a modified version of the alkaline lysis procedure originally described by Birnboim and Doly (Nucleic Acids Res. 7, 1513-1523, 1979). The handling of DNA samples is facilitated by the use of microtiter plates with membrane filter bottoms. All centrifugation steps are replaced by filtrations ("the filtration method"). The yield of plasmid DNA from 0.35 ml of an overnight culture is sufficient for restriction analysis of the plasmid clones. Up to 400 nucleotides' readable sequences could be obtained in cycle sequencing reactions with an unmodified sequencing protocol on an automated ABI sequencer.

Bacteriological Techniques↗

Matrix-assisted laser desorption/ionization mass spectrometry of immobilized duplex DNA probes.

Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry was used to analyze short DNA duplex probes with one strand immobilized on solid supports (straptavidin-coated magnetic beads or controlled pore glass beads). Only the non-immobilized strand could be detected. Partial denaturation was found when the duplex probes were mixed with 3-hydroxypicolinic acid, ammonium citrate matrix. The strategy has several applications, such as fast DNA sequence analysis and DNA diagnostics.

Base Sequence↗

Functionalized membrane supports for covalent protein microsequence analysis.

Methods were developed for high yield covalent attachment of peptides and proteins to isothiocyanate and arylamine-derivatized poly(vinylidene difluoride) membranes for solid-phase sequence analysis. Solutions of protein or peptide were dried onto 8-mm membrane disks such that the functional groups on the surface and the polypeptide were brought into close proximity. In the case of the isothiocyanate membrane, reaction between polypeptide amino groups and the surface isothiocyanate moieties was promoted by application of aqueous N-methylmorpholine. Attachment of proteins and peptides to the arylamine surface was achieved by application of water-soluble carbodiimide in a pH 5.0 buffer. Edman degradation of covalently bound polypeptides was accomplished with initial and repetitive sequence yields ranging from 33 to 75% and 88.5 to 98.5%, respectively. The yields were independent of the sample load (20 pmol to greater than 1 nmol) for either surface. Significant loss of material was not observed when attachment residues were encountered during sequence runs. Application of bovine beta-lactoglobulin A chain, staphylococcus protein A, or the peptide melittin to the isothiocyanate membrane allowed for extended N-terminal sequence identification (35 residues from 20 pmol of beta-lactoglobulin). A number of synthetic and naturally occurring peptides were sequenced to the C-terminal residue following attachment to the arylamine surface. In one example, 10 micrograms of bovine alpha-casein was digested with staphylococcal protease V8 and the peptides were separated by reverse-phase chromatography. Peptide fractions were then directly applied to arylamine membrane disks for covalent sequence analysis. From as little as 2 pmol of initial signal it was possible to determine substantial sequence information (greater than 10 residues).

Amines↗

Applications of dioxetane chemiluminescent probes to molecular biology.

DNA probes and synthetic oligonucleotides in general present one of the key tools in modern molecular biology research and increasingly also in commercial applications. Along with the many applications that have been developed for and with DNA probes, faster and more sensitive detection methods are being developed. One of the most promising recent developments presents a method based on enzymatically triggered chemiluminescence. Details of this chemistry along with applications in molecular biology and immunology will be discussed and compared to conventional methods.

Chemistry Techniques, Analytical↗

Solid-phase sequence analysis of proteins electroblotted or spotted onto polyvinylidene difluoride membranes.

Electroblotted proteins noncovalently bound to polyvinylidene difluoride (PVDF) membranes are typically sequenced using adsorptive sequencer protocols (gas-phase or pulsed-liquid) that do not require a covalent linkage between protein and surface. We have developed simple chemical protocols where proteins are first electroblotted onto unmodified PVDF membranes, visualized with common protein stains, and then immobilized for solid-phase sequence analysis. Adsorbed, stained proteins are first treated with phenylisothiocyanate (PITC) to modify alpha and epsilon amines. The protein is then overlayed with a solution of 1,4-phenylene di-isothiocyanate (DITC), followed by a few microliters of a basic solution containing a poly(alkylamine). As the polymer dries onto the surface both polymer and remaining protein amino groups are crosslinked by DITC. The protein is thus immobilized to the membrane surface by entrapment in a thin polymer coating. The coating is transparent to the degradation chemistry, and extensive enough to remain immobilized even in the absence of any covalent link between polymer and surface. Partial modification with PITC allows for identification of N-terminal and internal lysine residues during sequencing. The process was tested with a variety of poly(alkylamines), linear and branched, with molecular weights ranging from 600 to over 100,000. Proteins bound in this manner were successfully sequenced using covalent (solid-phase) sequencer protocols with cycle times as short as 26 min.

Absorption↗

A reliable method for random mutagenesis: the generation of mutant libraries using spiked oligodeoxyribonucleotide primers.

A new procedure for the production of a defined library of random mutants is described. Long spiked oligodeoxyribonucleotides (oligos), in which a predetermined level of the three 'wrong' phosphoramidites are used at each position, are made as primers for a standard oligo-directed mutagenesis protocol. Spiked oligo synthesis on a DNA synthesizer is achieved using an in-line mixing procedure that only requires five phosphoramidite reservoirs and which avoids contamination of any of the pure phosphoramidite reagents. Immutable positions (i.e., positions in the oligo for which pure reagents are used) can be specified, and a silent 'marker' base can be included that allows an early estimate of the mutagenesis efficiency. The randomness of the library in respect to the number, type, and position of the altered bases, is easily verified by DNA sequencing. This procedure has been used to generate a random mutant library of the gene encoding a sluggish triosephosphate isomerase. Among the transformants from this library, a number of second-site suppressor mutations have been found that increase the specific catalytic activity of the starting isomerase. This approach provides a more complete library than a method using chemical mutagenic reagents.

Base Sequence↗

Chemiluminescent detection of DNA: application for DNA sequencing and hybridization.

A non-radioactive DNA detection chemistry is described and its application is shown for DNA hybridization and standard dideoxy DNA sequencing. The method employes a biotin-streptavidin system which binds an enzyme specifically to a target DNA and upon exposure to substrate, the enzyme catalyzes a chemiluminescent reaction. The image is captured within seconds by a Polaroid or X-ray film. The method is capable of detecting DNA in the hundred attomol range.

Base Sequence↗

Escherichia coli RNA polymerase binding to a DNA terminus prevents formation of a closed promoter complex.

A 302 bp DNA fragment and a 113 bp subfragment of the former, both containing the fd gene VIII promoter (P VIII), were found to exhibit temperature-dependent differential behaviour in RNA chain initiation from P VIII. At 37 degrees C no significant differences were observed, while at 17 degrees C chain initiation was strongly suppressed only with the 113 bp fragment. This phenomenon depended on the presence of the (blunt) DNA terminus upstream from P VIII (position -70). Footprinting revealed that at 17 degrees C RNA polymerase was bound to this DNA fragment in a different mode. Contacts were observed only upstream from position -25. On the contrary, at 37 degrees C only the promoter complex footprint was visible. These results indicate that at 17 degrees C formation of the non-initiating complex is more favourable than formation of the promoter complex (which is closed at 17 degrees C; Hofer, B., Müller, D. and Köster, H. (1985) Nucleic Acids Res. 13, 5995-6013) and that formation of both complexes is mutually exclusive. No footprints of RNA polymerase were observed at other DNA termini. This indicates a sequence-specificity for the interaction at the terminus of the 113 bp fragment. The footprint pattern, together with features of the DNA sequence, suggests that the contacts involved in this interaction are similar to those promoter contacts formed upstream from position -20 and that DNA without a -10 region can be specifically recognized by RNA polymerase.

Bacterial Proteins↗