PubMed HealthSearch

Biomedical subjects

H Köymen

Publications and source records attributed to H Köymen.

5 recordsLinked to original sources

SVD-based on-line exercise ECG signal orthogonalization.

An orthogonalization method to eliminate unwanted signal components in standard 12-lead exercise electrocardiograms (ECG's) is presented in this work. A singular-value-decomposition-based algorithm is proposed to decompose the signal into two time-orthogonal subspaces; one containing the ECG and the other containing artifacts like baseline wander and electromyogram. The method makes use of redundancy in 12-lead ECG. The same method is also tested for reconstruction of a completely lost channel. The online implementation of the method is given. It is observed that the first two decomposed channels with highest energy are sufficient to reconstruct the ST-segment and J-point. The dimension of the signal space, on the other hand, does not exceed three. Data from 23 patients, with duration ranging from 9 to 21 min, are used.

Algorithms

Distribution of aortic mechanical prosthetic valve closure sound model parameters on the surface of the chest.

It has been previously proposed that heart valve closure sounds can be modeled by a sum of decaying sinusoids, based on the hypothesis that the heart cavity, heart walls, major vessels, and other structures in the chest constitute a frequency selective linear acoustic system and this system is excited by the rapidly decelerating valve occluder. In this study, distribution of the parameters of this model for the second heart sound is investigated. For this purpose, heart sounds of 10 patients who have a St. Jude-type bileaflet mechanical heart valve prosthesis in aortic position are recorded. Recordings are performed at 12 different locations on the surface of the chest. To reliably assign representative parameters to each recording site, signal averaging, model order selection, and a special filtration technique are employed. The results of the analyses are discussed in relation to the above hypothesis on the heart sound generation mechanism. It is observed that site-to-site variation of frequencies of modes does not exceed the accuracy limit of proposed analysis method, but energies of these modes vary on the surface of the chest, and as a result of statistical analysis, it appears that energy of some modes are significantly different between two recording sites.

Adolescent

Multichannel ECG data compression by multirate signal processing and transform domain coding techniques.

In this paper, a multilead ECG data compression method is presented. First, a linear transform is applied to the standard ECG lead signals which are highly correlated with each other. In this way a set of uncorrelated transform domain signals is obtained. Then, resulting transform domain signals are compressed using various coding methods, including multirate signal processing and transform domain coding techniques.

Algorithms

A new technique for line interference monitoring and reduction in biopotential amplifiers.

It has been reported that power line frequency must be accurately known if line interference is to be accurately subtracted from the output of a bipotential amplifier. In this paper, hardware developed to record the common mode line frequency signal on the body simultaneously with the ECG lead signals of a 15-channel computerized cardiograph is described. This interference reference signal and its quadrature, obtained by software, are linearly combined to be subtracted from any one of the channels to reduce line interference to below the quantization level of the 12 b A/D converter. Coefficients of the linear combination are estimated using linear regression which is applied to the relatively isoelectric regions of the data, excluding the QRS complexes. Since the interference reference signal is available in real time, simultaneously with the ECG signals, another software approach is also adopted in which an adaptive interference reduction algorithm is used to cope with varying interference. A recursive least squares algorithm with forgetting factor is used to update the coefficients. This updating mechanism is gated by the output of a software QRS detector. Results regarding the performance of both the off-line and the adaptive algorithms are given, and the effects of nonisoelectric portions of the ECG lead signals on the estimation of the coefficients are quantified.

Algorithms