PubMed Health⌕ Search

Biomedical subjects

H Kanitani

Publications and source records attributed to H Kanitani.

7 recordsLinked to original sources

Bone changes around hydroxyapatite and titanium implants after abutment placement in rabbits-observations using histological and three-dimensional examinations.

We have previously developed a computer-aided system for examination of the three-dimensional bone structure around implants and observed the bone changes in the healing period after implant placement. This paper describes the bone changes around hydroxyapatite (HA) and titanium (Ti) implants after abutment placement using histological and three-dimensional examinations. Twenty-four HA and Ti implants were embedded in the tibias of adult male New Zealand white rabbits. After 8 weeks, the abutment had passed through periosteum and was placed under the skin. Rabbits were sacrificed 4 and 8 weeks following abutment placement. In conclusion, histological examination showed that, at 4 weeks after abutment placement, bone resorption around the implant neck was seen in both HA and Ti implants, and at 8 weeks, excessive bone formation was seen around the implant neck. Three-dimensional bone examination showed that abutment placement may affect bone formation and cause additional bone hypertrophy in the bone marrow area.

Animals↗

Three-dimensional bone structure around hydroxyapatite and titanium implants in rabbits.

Long-term support of dental implants requires adequate bone thickness in the area surrounding the implant. A three-dimensional examination, including calculations of percent bone-implant contact and percent bone volume, was conducted to clarify the bone structure around pure titanium (Ti) and dense hydroxyapatite (HA) implants. The implants were installed in the tibiae of rabbits, and the bone structure was examined after 2, 4, 6 and 8 weeks. The bone formation following implantation differed in the cortical bone and cancellous bone areas. In the cortical bone area, the percent bone-implant contact and percent bone volume were comparatively consistent for both Ti and HA implants during the observation period. In the cancellous bone area, both findings were influenced by the implantation period, and the chronological bone structure in the cancellous bone area also differed between Ti and HA implants. The percent bone-implant contact and percent bone volume in the Ti implant increased over 8 weeks, whereas the dense HA implant increased for the first 4 weeks and then decreased. The implant materials, Ti and HA, affected the bone remodeling in the cancellous bone area.

Analysis of Variance↗

In vitro adherence of Streptococcus constellatus to dense hydroxyapatite and titanium.

Bacterial adherence to dense hydroxyapatite (HA) and titanium (Ti) rods was examined in vitro using Streptococcus constellatus ATCC27832. Streptoccus constellatus is associated with dental abscess and was isolated from the peri-implantitis. The dense HA was etched with 5% hydrofluoric acid for 0, 10, 20, 30, 40, and 50 s Adherence to the untreated dense HA was twice as high as the adherence to the Ti. The adherence to saliva-treated Ti was 13% higher than that to untreated Ti. The adherence was increased by acid-treatment of the dense HA, following a sigmoid curve from 20 to 50 s of treatment time. The dense HA has the capacity to receive more bacterial adherence than Ti and furthermore, the etched dense HA becomes more adherent.

Abscess↗

Three-dimensional examination of bone structure around hydroxyapatite implants using digital image processing.

This study introduced a new method for three-dimensional (3D) examination of the bone structure around an implant and presented 3D bone-implant contact rates. A block of nondecalcified implant tissue was ground gradually at an interval of 80 micrograms for the collection of serial two-dimensional (2D) images. An image of the stained block surface was instantly recorded by a charge-couple device (CCD) camera and computer-aided system. A 3D model was reconstructed from 60-70 sheets of serial 2D images. The 3D bone structure around the implant was shown in perspective and displayed all sides of the implant. The bone-implant contact rate depended on the cutting position and direction in the specimen. The 3D model will be necessary and valuable for the biomechanical study of dynamic bone changes around implants.

Animals↗

Influence of bone quality on the stress distribution. An in vitro experiment.

Adequate bone quality and stress distribution to the bone are of decisive importance for implant success. The purpose of this in vitro study was to investigate the influence of bone quality on the stress distribution using 2 implant-bone mimicking models, simulating compact and cancellous bone quality. The resin model was made of an acrylic resin only simulating compact bone quality. The hybrid model was made of 2 kinds of materials, acrylic resin covered with a 1-mm layer of urethane to simulate cancellous bone quality. An implant was embedded in each model, and the abutment and suprastructures were connected to the implant. A strain gauge was placed perpendicular to the implant on the surface of the model and a small accelerometer was attached to the abutment. When an impact load was applied to the suprastructure, both strain and acceleration were measured. Both abutment acceleration and surface strain in the hybrid model decreased rapidly as time progressed when compared to the resin model. Abutment accelerations in the resin model were significantly lower than those in the hybrid model. In the hybrid model, the strain increased as the loading site was moved closer to the strain gauge. The influence of loading sites on strain in the resin model was greater than in the hybrid model. Therefore, the occlusal stress was distributed more widely in the hybrid model than in the resin model. This may indicate that occlusal stress in compact bone may have a tendency to concentrate in particular regions.

Acrylic Resins↗

Rapid bone resorption adjacent to hydroxyapatite-coated implants.

This paper describes rapid bone resorption in the peri-implantitis of HA implants based on both our clinical observations of and histological research on extracted dense hydroxyapatite (HA) implants. The surfaces of extracted HA implants were rough, although they were smooth at fixture placement. Plaque formed on the necks of the implants, whereas little plaque was seen on the bottoms. The plaque consisted of cocci and rods, including filamentous bacteria. Few spirochetes were observed. Although surrounding bone was formed rapidly around the HA implant, bone thickness gradually decreased compared with the titanium implant. These facts suggest that the rigid biointegration of HA with the thin surrounding bone--that is, the overstressing of the bone--causes rapid bone resorption rather than plaque accumulation on HA.

Adult↗

Cross-reactivity between human sialyl Lewis(x) oligosaccharide and common causative oral bacteria of infective endocarditis.

The expression of sialy-Lewis(x) (sLe(x); Neu5Ac alpha 2-3 Gal beta 1-4) (Fuc alpha 1-3) GlcNAc-R) on oral bacteria producing infective endocarditis was determined by a whole-cell enzyme linked immunosorbent assay and an immunoelectron microscopy using the well-characterized anti-sLe(x) monoclonal antibody SNH-3 (mAb SNH-3; IgM class). mAb SNH-3 reacted strongly with whole cells of oral bacteria: Streptococcus sanguis, Streptococcus mutans, Streptococcus mitis, Streptococcus salivarius, Streptococcus intermedius, Streptococcus constellatus, Streptococcus anginosus, Streptococcus pyogenes, Actinobacillus actinomycetemcomitans, Eikenella corrodens and Porphyromonas gingivalis. The negatively stained immuno-electron micrograph of Streptococcus pyogenes showed many reactive gold particles on the cell surface. Our findings demonstrated the existence of immunologic mimicry between the sLe(x) oligosaccharide and cell surface antigens of many species associated with infective endocarditis. We propose the hypothesis that if these bacteria escape their normal habitats, the surface components that mimic the sLe(x) oligosaccharide might bind to host antigens of the selectin family which could promote binding to endothelial cells and, consequently, initiation of the events leading to infective endocarditis.

Antibodies, Monoclonal↗