PubMed Health⌕ Search

Biomedical subjects

H Kauczor

Publications and source records attributed to H Kauczor.

7 recordsLinked to original sources

Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by (3)He MRI.

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional input parameters. The time course of p(O(2)) during short periods of breathholding is found to be linear in a pig as well as in a human volunteer. We also measured the wall relaxation time in the lung and deduced a lower limit of 4.3 min.

Adult↗

Analysis of intrapulmonary O(2) concentration by MR imaging of inhaled hyperpolarized helium-3.

Inhalation of hyperpolarized (3)He allows magnetic resonance imaging (MRI) of ventilated airspaces. (3)He hyperpolarization decays more rapidly when interacting with paramagnetic O(2). We describe a method for in vivo determination of intrapulmonary O(2) concentrations ([O(2)]) based on MRI analysis of the fate of measured amounts of inhaled hyperpolarized (3)He in imaged regions of the lung. Anesthetized pigs underwent controlled normoventilation in a 1.5-T MRI unit. The inspired O(2) fraction was varied to achieve different end-tidal [O(2)] fractions (FET(O(2))). With the use of a specifically designed applicator, (3)He (100 ml, 35-45% polarized) was administered at a predefined time within single tidal volumes. During subsequent inspiratory apnea, serial two-dimensional images of airways and lungs were acquired. At least once in each animal studied, the radio-frequency excitation used for imaging was doubled at constant FET(O(2)). Signal intensity measurements in regions of interest of the animals' lungs (volume range, 54-294 cm(3)), taken at two different radio-frequency excitations, permitted calculation of [O(2)] in these regions of interest. The [O(2)] fractions in the regions of interest correlated closely with FET(O(2)) (R = 0.879; P < 0.0001). O(2)-sensitive (3)He-MRI may allow noninvasive study of regional distribution of ventilation and alveolar PO(2) in the lung.

Administration, Inhalation↗

Pulmonary nodules: detection with low-dose vs conventional-dose spiral CT.

The purpose of the study was the evaluation of low-dose spiral CT in the detection and assessment of contours of pulmonary nodules. In a prospective investigation 71 consecutive chest CT examinations were acquired both at 30 and 200 mA. Films were interpreted independently by two radiologists. According to the size, nodules were divided into four categories: </= 3, 4-5, 6-10, and > 10 mm; nodule shape was registered. With both protocols, 240 nodules were detected. The correlation coefficient for both methods was 0.89. Discrepancies were found most frequently in nodules near to pulmonary vessels. Nodule size estimation did not differ more than one size category. Eight spiculated nodules were identified by both techniques. Low-dose spiral CT of the chest has a high sensitivity in the detection of pulmonary nodules. If clinical circumstances require dose minimization, low-dose spiral CT may be advocated as an alternative screening method to conventional dose spiral CT.

Adolescent↗

MRI using hyperpolarized noble gases.

The aim of this study was to review the physical basis of MRI using hyperpolarized noble gases as well as the present status of preclinical and clinical applications. Non-radioactive noble gases with a nuclear spin 1/2 (He-3, Xe-129) can be hyperpolarized by optical pumping. Polarization is transferred from circularly polarized laser light to the noble-gas atoms via alkali-metal vapors (spin exchange) or metastable atoms (metastability exchange). Hyperpolarization results in a non-equilibrium polarization five orders of magnitude higher than the Boltzmann equilibrium compensating for the several 1000 times lower density of noble gases as compared with liquid state hydrogen concentrations in tissue and allows for short imaging times. Hyperpolarization can be stored sufficiently long (3 h to 6 days) to allow for transport and application. Magnetic resonance systems require a broadband radio-frequency system - which is generally available for MR spectroscopy - and dedicated coils. The hyperpolarized gases are administered as inhalative "contrast agents" allowing for imaging of the airways and airspaces. Besides the known anesthetic effect of xenon, no adverse effects are observed in volunteers or patients. Pulse sequences are optimized to effectively use the non-renewable hyperpolarization before it decays or is destroyed, using fast low-flip-angles strategies to allow for dynamic/breath-hold imaging of highly diffusible (He) or soluble (Xe) gases with in vivo T1-times well below 1 min. Since helium is not absorbed in considerable amounts, its application is restricted to the lung. Xe-129 is also under investigation for imaging of white matter disease and functional studies of cerebral perfusion. Magnetic resonance imaging using hyperpolarized gases is emerging as a technical challenge and opportunity for the MR community. Preliminary experience suggests potential for functional imaging of pulmonary ventilation and cerebral perfusion.

Adult↗

Detection of coronary artery calcifications predicting coronary heart disease: comparison of fluoroscopy and spiral CT.

The aim of this study was to evaluate the clinical relevance of coronary artery calcifications detected by spiral CT, congruence with fluoroscopy (FS) and coronary angiography, and comparison with studies reporting on application of double-helical CT and ultrafast CT. Forty patients underwent spiral CT (2-mm slice thickness, table feed 3 mm/s), coronary angiography, and FS (performed in the usual manner). Stenosis and calcifications were evaluated semiquantitatively. Nineteen patients suffering from a stenosis >/= 75 % were verified at coronary angiography. All had coronary artery calcification on spiral CT. Fluoroscopy did not detect 8 of 19 patients with a stenosis >/= 75 % (1 vessel: n = 1; 2 vessels: n = 3; 3 vessels: n = 4). In spiral CT sensitivity was 100 % and specificity was 33 % (FS: 58 and 48 %). Positive predictive value was 83 % for spiral CT (FS: 50 %), and negative predictive value was 100 % (FS: 56 %). A significant linear increase in the calcification score was found for increasing maximal stenosis (p < 0.005). Spiral CT is more sensitive than FS in the recognition of hemodynamic relevant stenoses using the detection of coronary artery calcifications. Statistical parameters are comparable to ultrafast-CT. Spiral CT is a suitable non-invasive diagnostic technique in coronary heart disease. Coronary calcifications found incidentally in symptomatic patients at chest CT should be reported to the referring physician for further cardiological workup.

Adult↗

Automatic detection of ground glass opacities on lung HRCT using multiple neural networks.

The purpose of this study was to implement neural networks and expert rules for the automatic detection of ground glass opacities (GG) on high-resolution computed tomography (HRCT). Different approaches using self-organizing neural nets as well as classifications of lung HRCT with and without the use of explicit textural parameters have been applied in preliminary studies. In the present study a hybrid network of three single nets and an expert rule was applied for the detection of GG on 120 HRCT scans from 20 patients suffering from different lung diseases. Single nets alone were not capable to reliably detect or exclude GG since the false-positive rate was greater than 100 % with regard to the area truly involved, more than 50 pixels throughout, and the true-positive rate was greater than 95 %. The hybrid network correctly classified 91 of 120 scans. Mild GG was false positive in 15 cases with less than 50 pixels, which was judged not clinically relevant. The pitfalls were: partial volume effects of bronchovascular bundles and the chest wall. Motion artefacts and diaphragm were responsible for 11 misclassifications. Hybrid networks represent a promising tool for an automatic pathology-detecting system. They are ready to use as a diagnostic assistant for detection, quantification and follow-up of ground glass opacities, and further applications are underway.

Expert Systems↗

[The aftercare of breast carcinoma. The value of plain thoracic radiography, abdominal sonography and mammography].

7865 follow-up examinations were performed on 420 patients who had had surgery for carcinoma of the breast; there were 2755 radiographs of the chest, 2660 sonographic examinations of the upper abdomen and 2450 contralateral mammograms. The most common findings were metastases seen on the chest radiographs during the 13-24 and 25-60 months intervals in 4.7% of cases. The incidence increased with initially higher tumour stages and in ductal carcinomas. Sonography of the upper abdomen showed 4.3% of liver involvement, mostly between the second and fifth year; this was independent of tumour stage or the histology of the primary tumour. Positive mammography of the contralateral breast was found in 3% within the first three months after surgery. A contralateral carcinoma was more common in case of lobular primary tumours. There was no direct correlation with the initial tumour stage. We evaluated the routine use of these imaging procedures as part of the follow up of carcinoma of the breast in relation to the additional cost.

Abdomen↗