PubMed HealthSearch

Biomedical subjects

H Kedra

Publications and source records attributed to H Kedra.

15 recordsLinked to original sources

[Biocorundum--a new/type of poreless ceramic material of aluminum oxide for the manufacture of the elements of hip joint prosthesis. Biological and technological studies].

The Institute of Refractories Materials in Gliwice undertook researches in the field of technology of a new ceramic material of aluminium oxide for production of coxal joint endoprostheses. A poreless ceramic material of high chemical purity and density and required microstructure and good resistance to fracture, was achieved. The new ceramic material was called Biocorundum. By means of a similar technology also series of samples were produced for testing the biocompatibility of the material. Biological studies were carried out in the Department of Experimental Surgery and Biomaterials Research, Chair of Traumatologic Surgery, Medical Academy of Wroclaw. The studies comprised: 1. laboratory and toxicological tests in vitro of water extracts, 2. pathomorphological studies after intramuscular, peritoneal and intra-bone implantation of samples of the material in rats and piglets, 3. ultrastructural scanning studies of the implantation in rats and pigs and after 3- and 6-months long keeping in the Ringer solution. Preliminary studies and biological studies in vitro have shown a complete conformity of the material with the requirements. Tissue reactivity was studied on 36 Wistar rats. By pathomorphological studies a systematic macroscopic and microscopic estimation was possible. They have shown only minimal tissue reactivity to biocorundum implantation. In experimental studies on 14 piglets the biocorundum grafts were implanted into the tibia epiphysis for 3- and 6-months. Clinical, pathomorphological and X-ray studies were carried out. In all cases the Biocorundum grafts healed without any complications. On the basis of pathomorphological studies, the tissue reactivity around the grafts were estimated as minimal. This shows a high biocompatibility of the ceramic material. In X-ray studies were observed around the grafts small osteosclerotic changes and periosteum stratification. These changes resulted after surgical interventions in quickly growing piglets. Complementary studies of the surface of the material by scanning microscopy after 3 months long implantation and after 3 months long contact with the Ringer solution did not show any changes in comparison with the surface of the initial samples. After 6 months long implantation in individual samples rounding of the ceramic material grain edges were found, which could result from biological corrosive power. This agree with the findings of other studies on other ceramic aluminium oxide materials. The achieved results of complex studies of biocompatibility of the new poreless material developed in Poland--Biocorundum--have shown its complete biological suitability for production of elements of osteoarticul

Aluminum

[Use of fibrin glue in tracheal surgery. Experimental studies].

The experimental studies were undertaken in order to estimate the suitability of fibrin sealant in tracheal surgery and the compare tissue reactivity after using cyanoacrylic and fibrin adhesives. 14 piglets of the Poland white breed, weighing up to 25 kg, were used in the study. Under general tracheal anesthesis the tracheal wall was cut open by incision on the mid-line on the neck between the III-IV tubular cartilages along 3/4 of its circumference. The lips of the incision were closed by one atraumatic suture and tightened by fibrin sealant. Piglets dissecting examinations were carried out after 24 hours, 3, 7, 14, 30, 60 and 90 days after the operation. The results were estimated by macro- and microscopic studies. Comparative studies were carried out on the basis of our own similar experimental studies by means of cyanoacrylates. It was found that the Immuno fibrin adhesive is a very useful new material for tightening the tracheal wounds. The Immuno fibrin adhesive, in comparison with cyanoacrylates, has very good biological qualities, does not cause marginal tissue necrosis and increased chronic inflammatory changes. Fibrin sealant undergoes complete elimination from the wound after 7-10 days and is replaced by connective tissue.

Animals

Radiosterilized polyester knitted nets Dallop.

Polish surgical polyester knitted nets Dallop sterilized by radiation were implanted and tested on Wistar rats. The results of the experimental evaluation are positive and lead to the conclusion that the Dallop radiosterilized polyester nets may be used in humans. The evaluated knittings fulfill the most up-to-date biological requirements and may be utilized as implantation material for plastic and reconstructive surgery.

Abdomen

[Physical and biological examinations of polyester electret foil. Preliminary report].

The results of tissue reaction to polyester thermoelectret foil samples are evaluated. The electrostatic measurement of the foils was performed before implantation. The experimental animals were divided into four groups depending on the surface charge density of the foils. The autopsy of the animals was performed three days after the operation. The tissues of close contact to the foil were examined under the microscope and the electrostatic measurement of the foils.

Animals

[Clinical study of resorbable surgical sutures. A suggestion].

There has been attempted in the Institute of Surgery, Wrocław Medical School, in 1975 the clinica study with the purpose of comparative evaluation of two kinds of tissue-resorbable surgical sutures, namely catgut and polyglycolic acid threads. To standardize the basic methods of clinical examination to be followed by teams of experts, basing on literature data and own experience, a proposition was elaborated including indications and methods of choosing the groups of resorbable and non-resorbable threads, aseptic demands, and intraoperative, postoperative and laboratory examinations.

Biological Products