Development of an HPLC method for simultaneous analysis of five antineoplastic agents.

Simultaneous analysis of common antineoplastic agents potentially hazardous to healthcare workers is of much interest for the evaluation of the overall health risk to these workers. Such analysis could be applied to both air and surface monitoring samples to provide a broader indication of risk to combinations of these agents. It was determined that the ability to simultaneously evaluate five frequently used, potentially hazardous agents was sufficient for general evaluation of exposures to healthcare workers. The approach used to select the five agents was to obtain a list of the agents used most frequently in both a cancer hospital and an outpatient cancer treatment center, then review the list to determine which agents were potentially more hazardous to human health. From these reviews, it was decided to attempt to develop an analytical method able to detect and quantify the presence of 5-fluorouracil, ifosfamide, cyclophosphamide, doxorubicin HCl, and paclitaxel. A reverse-phase high performance liquid chromatograph (HPLC) with a Waters Symmetry C8 column and a UV wavelength of 195 nm was selected for method development. The mobile phase was 22.75 percent acetonitrile in water buffered to a pH of 6.0. The HPLC analytical method developed is able to detect all five agents of interest, and at minimum detectable concentrations of 0.5-microgram/mL for each of the five agents.

Ambulatory Care Facilities↗

A new monitoring method using solid sorbent media for evaluation of airborne cyclophosphamide and other antineoplastic agents.

Cyclophosphamide is a known human carcinogen. In July 1999, in a report at a conference on cytotoxic drugs in Sweden, it was indicated that cyclophosphamide (CP) was not effectively controlled by high efficiency particulate air (HEPA) filters.((1)) This then raised a concern that the existing air monitoring methods, which utilize polytetrafluoroethylene (a.k.a. PTFE, or Teflon) or glass fiber filters for evaluation of antineoplastics such as CP in air may also be ineffective for collection and quantification of such agents. It was decided that further evaluation of the existing filter method for monitoring antineoplastics in air be conducted. This evaluation determined that the filter method of monitoring was minimally effective for some antineoplastic agents, and that an alternate method of monitoring should be sought. The method subsequently developed utilizes a solid sorbent tube, Anasorb 708, a methacrylic acid polymer. Evaluation of this sorbent tube for adsorption and desorption properties found it had a greater than 90 percent recovery for both CP and ifosfamide. Other agents evaluated included 5-fluorouracil, doxorubicin, and paclitaxel. All three agents were able to be detected and measured by use of Anasorb 708 solid sorbent tube. Validation of the method was then conducted with air pulled through the tubes via attachment to an air manifold system at air flows ranging from 1.5 to approximately 4.0 liters per minute for up to 24 hours. This evaluation did validate the Anasorb 708 tube as an effective media for collection of airborne concentrations of CP from less than 1 microgram up to approximately 2 mg (2000 microgram) per tube. This corresponds to a concentration range of approximately 0.7 microgram/m(3) (0.0007 mg/m(3)) to 0.7 mg/m(3) in a 5.76 m(3) volume of air. This method can provide accurate information on airborne concentrations of CP for purposes of conducting risk assessments or evaluation of risk management methods.

Adsorption↗

Monitoring method for surface contamination caused by selected antineoplastic agents.

A method of evaluating surface contamination caused by selected antineoplastic agents was studied. The antineoplastic agents tested were cyclophosphamide, ifosfamide, doxorubicin hydrochloride, fluorouracil, and paclitaxel. Each agent was reconstituted and prepared as a stock solution. A 0.1-mL portion of each solution was spread evenly over a 600-cm2 area of a stainless steel surface, a resin countertop surface, and a vinyl flooring surface. After drying, the surfaces were wiped with each of two types of commercially available wiping materials (What-man no. 42 filters and Kimberly-Clark Kimwipes). A blend of methanol, acetonitrile, and buffered water was used both as the wetting agent for wiping the surfaces and as a desorbing solution. The desorbate was analyzed for drug concentration by reverse-phase high-performance liquid chromatography (HPLC). Mean +/- S.D. percent total recovery ranged from 72.4% +/- 17.6% to 95.3% +/- 2.9% for the vinyl surface wiped with filters, 91.5% +/- 5.4% to 104.7% +/- 0.8% for the resin surface wiped with filters, 73.9% +/- 2.3% to 95.3% +/- 1.7% for the stainless steel surface wiped with filters, and 18.2% +/- 1.4% to 372.8% +/- 8.0% for the stainless steel surface wiped with Kimwipes. Results were best for ifosfamide and cyclophosphamide. Kimwipes were deemed ineffective for this monitoring method because an ingredient interfered with the quantitative analytical tests. A wipe-sampling, desorption, and HPLC method for monitoring surface contamination by selected antineoplastic agents was sufficiently accurate and sensitive to evaluate surfaces typically found in both the pharmacy and drug administration areas of oncology treatment facilities.

Antineoplastic Agents↗

A comparison of two surface sample collection devices for use in polymerase chain reaction based detection of Pneumocystis carinii in house dust.

A polymerase chain reaction assay was optimized to detect P. carinii cysts in composite dust samples. The optimal assay was capable of detecting as few as 10(3) P. carinii cysts in 50 mg of dust. Two dust collection devices were evaluated for efficiency and precision of collection of bulk dust and compatibility with the optimized PCR protocol for P. carinii DNA detection. A handheld vacuum cleaner equipped with a high-retention bag was found to be superior to a 37-mm filter cassette attached to an electrically powered vacuum pump in terms of dust collection efficiency (87% [n = 37] versus 81% [n = 35]), although the precision of the two devices as assessed by the standard deviation was similar (6.2% versus 6.3%). However, the vacuum cleaner method was not as compatible with the PCR-based detection assay as the filter cassette method. The filter cassette appears to be a better device for use in conjunction with PCR-based detection of P. carinii DNA in bulk dust samples from both smooth and carpeted surfaces.

DNA, Fungal↗