PubMed Health⌕ Search

Biomedical subjects

H Kolem

Publications and source records attributed to H Kolem.

13 recordsLinked to original sources

Localized spectroscopy from anatomically matched compartments: improved sensitivity and localization for cardiac 31P MRS in humans.

Several pioneering studies have demonstrated that localized 31P NMR spectroscopy of the human heart might become an important diagnostic tool in cardiology. The main limitation is due to the low sensitivity of these experiments, allowing only crude spatial resolution. We have implemented a three-dimensional version of SLOOP ("spectral localization with optimal pointspread function") on a clinical instrument. SLOOP takes advantage of all available a priori information to match the size and the shape of the sensitive volumes to the anatomical structures in the examined subject. Thus, SLOOP reduces the contamination from adjacent organs and improves the sensitivity compared to conventional techniques such as ISIS or chemical shift imaging (CSI). Initial studies were performed on six healthy volunteers at 1.5 T. The good localization properties are demonstrated by the absence of resonances from blood in the heart spectra, and by PCr-free spectra from the liver. Compared to conventional CSI, the signal-to-noise ratio of the SLOOP heart spectra was improved by approximately 30%. Taking into account the varying excitation angle in the inhomogeneous B1 field of the surface coil, the SLOOP model computes the local spin saturation at every point in space. Therefore, no global saturation correction is required in the quantitative evaluation of local spectra. In this study, we found a PCr/gamma-ATP ratio in the left ventricular wall of 1.90 +/- 0.33 (mean +/- standard deviation).

Adenosine Triphosphate↗

Effect of physical exercise on cartilage volume and thickness in vivo: MR imaging study.

PURPOSE: To quantify, with magnetic resonance (MR) imaging, the in vivo changes in cartilage volume and thickness after physical exercise. MATERIALS AND METHODS: The patellae of eight volunteers were imaged six times at physical test by using a spoiled fat-suppressed gradient-echo sequence with an acquisition time of 4.10 minutes. The volunteers then performed 50 knee bends, and two more data sets were acquired 3-7 minutes and 8-12 minutes after exercise. The patellar cartilage volume was determined after three-dimensional reconstruction, and the thickness was assessed with a three-dimensional minimal-distance algorithm. RESULTS: Whereas repositioning had a small effect on the measurements (mean coefficient of variation, 1.4%), a statistically significant decrease in cartilage volume was observed 3-7 minutes (mean decrease, 6.0%; P < .05) and 8-12 minutes (mean decrease, 5.2%; P < .05) after exercise. The deformation was homogeneous throughout the joint surface. In one asymptomatic volunteer, a cartilage lesion became more pronounced after exercise. CONCLUSIONS: MR imaging can be used to investigate the response of articular cartilage to physical exercise in vivo. Patients or volunteers should be allowed a sufficient period of physical rest if quantitative measurements of cartilage volume and thickness are to be undertaken in longitudinal studies.

Adult↗

[Preoperative marking of non-palpable mammary lesions on the magnetic resonance image using a body coil].

PURPOSE: To evaluate the efficacy of a MRI localization procedure using a non-dedicated body coil in lesions only visible in MRI. MATERIAL AND METHODS: In 18 patients, we performed a contrast enhanced (i.v. 0.2 mmol Gd-DTPA/kg b.w.) breast MRI on a 1.0 Tesla system (Magnetom Impact, Siemens, Erlangen, Germany) using a body coil and a GRE 3D sequence. In prone position, the patients were placed in a customized positioning device offering lateral access to the breast. The localizations were done with a MRI-compatible wire (n = 21). In addition, all patients underwent the same imaging protocol using a dedicated breast coil (without localization). For both MRI modalities, the signal intensities of the lesion, the normal breast tissue, and the background noise were measured. The lesion-to-fat contrast (LFC), the lesion-to-fat contrast (LFC), the lesion-to-breast tissue contrast (LBC) and the percentage of signal change pre and post contrast administration were calculated and compared. The localisation results were correlated to pathologic findings. RESULTS: There was no difference in lesion detection (lesion size: 0.5 to 1.2 cm) between the body coil and the dedicated breast coil. Regarding the LFC and LBC, the body coil was superior to the dedicated breast coil (no statistical significance). However, the background noise was higher using the body coil. In all cases the localisation was successful. CONCLUSION: In our preliminary experience, detection of breast lesions and wire-localization of the lesion by MRI is efficient and reliable using a non-dedicated body coil.

Adult↗

Duration of lithium treatment and brain lithium concentration in patients with unipolar and schizoaffective disorder--a study with magnetic resonance spectroscopy.

Twenty psychiatric patients on lithium medication were examined with 7-Li-magnetic resonance spectroscopy of the brain. Patients on long-term lithium treatment (> 6 months) were compared with a short-term group who had been taking lithium for between 4 and 8 weeks. Patients met DSM-III-R criteria for either recurrent unipolar depressive disorder (DSM-III-R 296.3x) or schizoaffective disorder, depressive type (DSM-III-R 295.70). The brain:serum lithium ratio was 0.76 +/- 0.26; there was no significant difference between short-term and long-term treatment. In the group of long-term treatment patients there was a positive correlation between lithium dose per day and brain lithium concentration (R = .72, p < .01), and between lithium plasma concentration and brain lithium concentration (R = .65, p < .05). In the short-term group, however, there was no significant correlation for these parameters. No differences between unipolar and schizoaffective disorder were found.

Adult↗

Repeatability of patellar cartilage thickness patterns in the living, using a fat-suppressed magnetic resonance imaging sequence with short acquisition time and three-dimensional data processing.

A fast, reproducible, and noninvasive method is required for quantifying cartilage thickness clinically and for studying the deformation of articular cartilage during and after mechanical loading in vivo. The objective of the current investigation was to test the repeatability of regional distribution patterns of patellar cartilage thickness in the living on the basis of a fat-suppressed magnetic resonance imaging sequence with a short acquisition time and three-dimensional digital data processing. The knees of eight healthy volunteers were transversally imaged with a fat-suppressed FLASH-3D (fast low angle shot) sequence (acquisition time: 4 minutes and 10 seconds). In each case, the joint was newly positioned before each of the six replicate measurements was taken. The patellar cartilage was reconstructed three-dimensionally, and the distribution of cartilage thickness was determined with a three-dimensional minimal-distance algorithm. Whereas the cartilage volume ranged from 3,198 to 7,149 mm3, the mean coefficient of variation for the 6-fold volume measurement was 1.35%. On average, 75.1% (+/- 4.1%) of all test pixels could be attributed to the same cartilage thickness interval (0.5 mm) by image analysis; 14.8% (+/- 2.4%) deviated by one interval; 6.6% (+/- 1.5%), by two intervals; and 3.5% (+/- 1.8%), by more than two intervals. We conclude that, on the basis of a magnetic resonance imaging sequence with an acquisition time of less than 5 minutes, the quantitative distribution of cartilage thickness can be determined with high precision in vivo.

Adult↗

Oblique proton chemical shift imaging for the presurgical localization of mesial temporal epilepsy.

Precise localization of the epileptogenic zone in patients suffering from mesial temporal lobe epilepsies is a prerequisite for surgery. For this purpose, a scheme for selecting the volume of interest in an oblique plane covering the head, body, and tail of the hippocampal formation (HF) was implemented in a water-suppressed proton chemical shift imaging (CSI) acquisition. This approach, evaluated by consecutively acquired CSI spectra of both temporal lobes, demonstrates that it can potentially be a routine technique for clinical diagnosis. Since the method produces localized spectral detail of the HF, it facilitates a convenient comparison of CSI lateralization to that assessed by HF atrophy (due to sclerosis) using the MRI-volumetry technique.

Adult↗

[MR mammography. Preoperative marking of non-palpable breast lesions with the Magnetom open at 0.2 T].

PURPOSE: To answer the following questions: whether reliable detection of lesions is possible in low-field-MRI-system (Magnetom Open 0.2 T) equipped with currently available hard- and software components in comparison to high field system (Magnetom Impact 1.0 T). Furthermore, whether localization of lesions suspect in MR-mammography can be realized in MR system of low field (Magnetom Open 0.2 T). PATIENTS AND METHODS: In 11 patients, suspect lesions were diagnosed in diagnostic MR-mammography acquired with high field system (Magnetom Impact 1.0 T) and were compared to low field MR-mammographies of 0.2 T (Magnetom Open 0.2 T). In six of the 11 patients a suspect lesion was localized using wire marking. RESULTS: All lesions considered suspect in diagnostic MR-mammography (Magnetom Impact 1.0 T) were also clearly identified in the 0.2 T system (Magnetom Open). In six cases wire marking was performed without any complications and with an accuracy of < or = 0.5 cm distance to the lesion. CONCLUSION: Although studies in the 0.2 T system clearly showed inferior SNR (34.6 vs. 83.1) and CNR (14.6 vs. 43.5) compared to studies with the high field system, all lesions considered suspect in diagnostic MR-mammography were reliably identified also in 0.2 T studies. Due to its open construction permitting permanent access to the breast and due to sufficient image quality, the Magnetom Open is suitable for interventions on the breast.

Biopsy↗

A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 2: Validation using CT arthrography.

Established methods for the measurement of articular cartilage thickness are invasive and cannot be sequentially applied in living subjects. In the present study, the distribution of cartilage thickness throughout entire joint surfaces was determined from MR images obtained with a fat-suppressed gradient-echo sequence at a resolution of 0.31 x 0.31 x 2.00 mm3, and compared to that derived from CT arthrography. A minimal distance algorithm was employed to produce 3D cartilage thickness maps of seven cadaveric human knee joints. The mean amount of deviation of the cartilage volumes was 5.6% (+/- 4.6), statistical analysis showing that there was high agreement between the two methods (r = 0.995, slope = 1.037, y-intercept = -90.5 mm3). The 3D thickness maps yielded a striking agreement between the two methods, the maximum values generally yielding a deviation of none or one thickness interval of 0.5 mm. This investigation shows that accurate 3D assessment of articular cartilage thickness can be performed with MRI, this technique having the advantage that it is suitable for investigating living subjects.

Adult↗

[Three-dimensional thickness and volume measurements of the knee joint cartilage by MR tomography: reproducibility in volunteers].

OBJECTIVE: To determine the reproducibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. METHODS: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagittally imaged with a resolution of 2 x 0.31 x 0.31 mm3, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. RESULTS: The mean variation of the cartilage volumes of the replicate measurements was 1.4% (+/- 0.8%) in the patella, 1.7% (+/- 1.5%) in the femur, 3.0% (+/- 1.2%) in the medial tibial plateau and 3.5% (+/- 2.0%) in the lateral tibial plateau. The comparison of the distribution patterns of cartilage thickness yielded a high degree of agreement. Only in rare cases deviations of more than 0.5 mm were observed. CONCLUSIONS: The results show that the presented method for determining the quantitative distribution of articular cartilage yields a high degree of precision. It offers new possibilities in screening risk groups, monitoring the course of degenerative joint disease and the investigation of functional adaptation of the cartilage to mechanical loading.

Adult↗

Localized proton NMR spectroscopy in the striatum of patients with idiopathic Parkinson's disease: a multicenter pilot study.

Single voxel proton MRS was used to study brain metabolism in the striatum of patients diagnosed with idiopathic Parkinson's disease (PD). Peak metabolite ratios in long echo time spectra were evaluated in 151 patient spectra and 97 age-matched control spectra collected at four participating institutions using identical hardware and clinical protocols. Combining data from all ages (27-83 years old) showed no significant difference between patient and control ratios. However, in an elderly subset of patients (51-70 years old), a significant decrease in striatal N-acetylaspartate (NAA)/choline (Cho) was observed. Also, a significant decrease in the mean NAA/Cho ratio was observed in patients versus controls for patients not being treated with Sinemet (Du Pont Pharm, Wilmington, DE) (hereafter referred to as levodopa/carbidopa). This result is consistent with the hypothesis that NAA may provide a reversible spectroscopic marker for neuronal dysfunction, although a prospective follow-up study will be needed to confirm this. Quantitation of MRS would be useful to exclude the possibility that a change in Cho levels affected the NAA/Cho ratios.

Adult↗

Temporal lobe epilepsy: presurgical localization with proton chemical shift imaging.

PURPOSE: To assess two-dimensional phase-encoded proton chemical shift imaging for potential clinical application in presurgical localization of temporal lobe epilepsy (TLE). MATERIALS AND METHODS: Interictal chemical shift imaging studies were performed in 25 patients (17 unilateral, eight bilateral epileptogenic abnormalities) and 12 healthy volunteers. Results were compared with those of electroencephalography. For each temporal lobe, the volume of interest (VOI) included mesial, lateral, anterior, and posterior areas. RESULTS: The epileptogenic zone was characterized by an abnormal pattern of decreased signal intensity in the N-acetylaspartate (NAA) peak, either increased or unchanged choline (Cho) level relative to creatine (Cr) signal intensity, and, occasionally, elevated lactate level. NAA/Cho was the most sensitive and reliable quantitative marker for abnormality. The sensitivity and specificity of this technique compared with EEG were 90% and 85%, respectively. The difference in NAA/Cho between epileptogenic and normal temporal lobes was highly significant (P < .001). No statistically significant difference was found between normal temporal lobes and patients' uninvolved temporal lobes. CONCLUSION: NAA/Cho is an excellent marker for localizing the epileptogenic zone in TLE.

Adolescent↗

[Clinical magnetic resonance spectroscopy: feasibility and methods using whole body tomographs].

MR Spectroscopy offers the unique possibility of monitoring the metabolism of various organs non-invasively. Using examples of 1H and 31P MR spectra, experimental and commercially available techniques are presented and evaluated with regard to their potential clinical application. An example of a 1H human brain spectrum with a pathological lactate level illustrates the requirements for MRS examinations in terms of spatial and spectral resolution. STEAM, Spin-Echo, and Chemical Shift Resolved Imaging (CSI) techniques for 1H MRS are compared. In the field of 31P MRS, typical CSI spectra of the brain and liver are presented. First experimental results with a new double-oblique 3D-CSI technique for measurement of PCr/ATP ratios of different anatomical regions of the human heart are shown. The advantages of using double-resonance techniques for Nuclear Overhauser Enhancement (NOE) and decoupling are shown by the example of the phosphodiesters of the liver. The energy metabolism of skeletal muscle under exercise is resolved with 5 sec/spectrum, showing breakdown and synthesis of photocreatine (PCr) and inorganic phosphate (Pi). Appropriate instrumentation and technique are available to many clinics today; great interest now is directed towards the diagnostic value of MRS for certain indications.

Brain↗

Comparison of in vivo and in vitro Hahn T2 measurements in rat lung.

We compared in vivo and in vitro Hahn echo T2 measurements in rat lungs in both imaging and nonimaging modes. All measurements could be characterized by multiexponential functions consisting of either two or three exponentials. Essentially the same values of the time constants were observed for spontaneously breathing rats and for excised lungs.

Animals↗