PubMed Health⌕ Search

Biomedical subjects

H Kunov

Publications and source records attributed to H Kunov.

At least 37 records · Page 2Linked to original sources

Lateralization based on interaural phase differences: effects of frequency, amplitude, duration, and shape of rise/decay.

Experiments in lateralization were performed to evaluate the relative contribution of envelope and phase cues in binaural hearing with particular reference to the effects of frequency, amplitude, shape of rise/decay, and duration of peak amplitude. Pure-tone signals were presented with interaural phase shifts ranging between 90 degrees and 360 degrees. For a given value of phase shift, the leading signal was presented randomly to the right or left ear over a block of 100 trials, and the laterality of the resultant image was judged. Rise/decay time was varied from 5 to 200 ms across blocks. The results confirmed our previous finding that a rise/decay time of at least 200 ms is required to secure a psychophysically steady-state signal. This value will, however, depend on the values chosen for the other signal parameters. Within limits, decreasing intensity could be compensated for by decreasing rise/decay, suggesting the psychophysical importance of the initial segment of the signal (precedence effect). For low frequencies of 650 to 1250 Hz, performance is sensitive to interaural phase shift and largely independent of frequency. For higher frequencies of 1500 and 2000 Hz, lateralization is independent of the phase cue and also largely insensitive to change in rise/decay time. Finally, performance remains unchanged with variation in peak duration ranging from 25 to 200 ms.

Dominance, Cerebral↗

Electrotonic parameters of rat dentate granule cells measured using short current pulses and HRP staining.

The passive electrotonic parameters of nerve cells in the dentate gyrus of the rat were studied in vitro. Intracellular recordings from 30 granule cells and 3 pyramidal basket cells followed by intracellular injection of horseradish peroxidase (HRP), allowed calculations of input resistance (RN), membrane time constant (tau m), electrotonic length (L), ratio of dendritic to somatic conductance (rho), membrane specific capacitance and resistance (Rm, Cm), and specific axoplasmic resistance (Ri). The analysis of the voltage decays from long saturating (100 ms) and short (0.5 ms) current pulses showed that the short-pulse method gave better resolution for the measurement of the time constants and avoided some of the time-dependent nonlinearities but required larger currents than the long pulse. Morphological analysis of 49 branching points taken from the dendritic trees of granule cells showed that the branching power, n, is equal to 1.56 +/- 0.186 and was fairly constant throughout the tree. Given the fact that all dendrites have approximately the same length and number of branch points, the granule cell dendritic tree can be meaningfully collapsed into an equivalent cable. Moreover, electrophysiological data suggested that the cable had a "sealed" end or at least a high-impedance termination. Based on an equivalent cable model with a sealed end and a lumped soma impedance, a method was implemented to analyze the multiexponential decays from hyperpolarizing current pulses and to solve the equations of the model. This was done successfully in only 40% of the cells and yielded the following mean values for L = 1.13 and rho = 7.58. From the measurements of the soma surface area (S) and the equivalent cable diameter (D), the average specific membrane parameters were calculated: Rm = 2,726 alpha x cm2, Cm = 5.24 microF/cm2, Ri = 101 alpha x cm. The input resistance and time constant of the granule cells as measured from the short-pulse technique averaged to RN 58.57 M alpha and tau m = 16.21 ms. The failure of the model to fit 60% of the cells was interpreted to be due to the presence of a somatic shunt resulting from electrode injury, tonic synaptic activity, a lower somatic membrane specific resistance, or electronic coupling.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

The effect of hearing protection on narrowband signal detection in industrial noise.

A method for evaluating the effectiveness of insert protectors at suprathreshold intensities was developed. Normal listeners and workers with clinically diagnosed, bilateral, noise-induced hearing loss attempted to detect a 1 or 3 kHz narrowband signal, 500 msec in duration. The signal was presented binaurally over headphones, either in quiet or against a background of industrial noise taped on site. The level of the noise was fixed at 84 dBA. The level of the signal was varied across blocks of 50 trials from near threshold to clearly audible. Comparisons were made between the detectability of the signal when insert protectors were worn, and listening without protection. The results indicated that in both normal and hearing impaired listeners the slopes of the psychometric functions were fairly steep, covering a range of only about 5 dB. The value of attenuation of the insert protector derived from the displacement of the function for listening in quiet with the protector, relative to listening with the open ear was constant throughout the range of suprathreshold signal intensities used. In 84 dBA of background noise normal subjects showed an improvement of about 3 dB when they wore protectors. By contrast the wearing of protectors in noise by hearing impaired listeners resulted in substantial decrements in signal detection.

Audiometry↗

The effect of displacement current on the measurement of reversal potential in squid giant axon.

The measurement of the sodium reversal potential (Erev), as that potential where the early current reverses during voltage clamp, was found to exceed the true Erev by 4.1 +/- 2.4 mV (mean +/- SD) in squid giant axon. This error was found in both intact and internally perfused axons and is due to interference from the displacement current. This was shown by subtraction of the current records obtained before and after treatment with tetrodotoxin (TTX). The error in Erev is proportional to (Td/gNA)12 where Td is the time constant of the displacement current.

Animals↗

Effects of rise/decay time on the lateralization of interaurally delayed 1-kHz tones.

Experiments in lateralization were performed to evaluate the relative contribution of onset and phase cues in binaural hearing. A 1-kHz signal was presented with interaural stimulus delays ranging from 0 to 1000 microseconds, corresponding to phase shifts of 0 degree to 360 degrees. For a given value of delay, the leading signal was presented randomly to the right or left ear over a block of 100 trials, and the laterality of the resultant image was judged. The percentage of correct judgments was plotted as a function of delay with rise/decay time as a parameter. Values of rise/decay time ranged from 0 to 500 ms. The results indicated that rise/decay times of at least 200 ms are necessary to avoid contributions from the onset cue to the formation of lateralization judgments. For rise/decay times shorter than 200 ms, a conflict occurs between phase and onset cues in the region of phase shifts from 180 degrees to 360 degrees. At the limit with very short rise/decay times, the onset cue completely overrides the phase cue.

Acoustic Stimulation↗

The "eardrum artifact" in ipsilateral reflex measurements.

A source of error in ipsilateral reflex measurements with impedance methods is explained. It is shown that the inherent non-linearity of the cavity represented by the ear canal and tympanic membrane gives rise to an artifact in the measurement of acoustic impedance which is synchronous with the stimulus. The magnitude of the artifact increases with the intensity of the stimulus, but is relatively insensitive to the frequency of the stimulus. A practical method for measuring the magnitude of the artifact is described.

Acoustic Impedance Tests↗