PubMed Health⌕ Search

Biomedical subjects

H L Boyd

Publications and source records attributed to H L Boyd.

4 recordsLinked to original sources

Normal values for left ventricular volumes obtained using gated PET.

BACKGROUND: Accurate assessment of left ventricular (LV) volumes provides important insights into myocardial function, being particularly important for diseases of the heart in which there is progressive dilatation of the LV, such as remodeling after myocardial infarction. We have recently validated a method for measuring LV volumes using gated positron emission tomography (PET) with oxygen-15 labeled carbon monoxide (C15O). The present study was performed to establish normal values for LV volumes, in absolute units, using this technique. METHODS: Forty subjects [21 males and 19 females; age 49 +/- 13 years (mean +/- SD), range 24-80; body surface area (BSA) range 1.50-2.18 m2] were studied. End diastolic (EDV) and end systolic volumes (ESV) were calculated by determining the edge of the end diastolic and end systolic blood pool images (obtained using PET with C15O) and summing the volume of the voxels comprising the blood pool. RESULTS: For the overall study population, EDV was 109 +/- 20 ml and ESV 37 +/- 12 ml. When stratified according to gender, these values were: in males, EDV was 117 +/- 18 ml and ESV 42 +/- 18 ml; in females, EDV was 100 +/- 19 ml and ESV 32 +/- 8 ml. The differences between gender groups (EDV: p = 0.0027, ESV: p = 0.0029) were eliminated when volumes were corrected for BSA. CONCLUSIONS: These data will form a database of normal values for comparison with pathological conditions of the heart. PET quantification of LV volumes offers a means of measurement of function using an imaging modality that can also assess regional myocardial perfusion and metabolism during the same study session.

Adult↗

Non-invasive measurement of left ventricular volumes and function by gated positron emission tomography.

To date cardiac positron emission tomography (PET) studies have focussed on the measurement of myocardial blood flow, metabolism and receptors while left ventricular (LV) function and dimensions have been derived from other modalities. The main drawback of this approach is the difficulty of data co-registration, which limits clinical interpretation. The aim of this study was to evaluate whether it is possible to measure absolute cardiac volumes, and consequently LV function parameters such as ejection fraction, and wall motion with gated PET. Nineteen patients underwent a PET scan and planar radionuclide ventriculography (MUGA) within 9+/-9 days. A 9-min scan (16 gates/cardiac cycle) was acquired after inhalation of 3 MBq/ml of oxygen-15 labelled carbon monoxide at the rate of 500 ml/min over 4 min using a multislice PET camera. Noise reduction was performed on the gated image to enhance the definition of the ventricles before reslicing to the short-axis view. A threshold value was used to detect the edge of the LV at each gate. LV volumes at each gate were estimated by summing the volume of voxels within the LV boundary. PET measurements of LV volumes were as follows: LV end-diastolic volume ranged from 72 to 233 ml and LV end-systolic volume ranged from 24 to 203 ml. Phantom experiments supported the validity of this approach for estimating volumes. LV ejection fraction measured with MUGA was 38.4%+/-16.3% (range 15%-71%) and that measured with PET was 39.6%+/-17.7% (range 9%-72%) (P=NS). The LV ejection fraction measurements were highly correlated (r2=0.824). These results indicate that: (1) absolute end-diastolic and end-systolic volumes can be quantified using gated PET and (2) LV ejection fraction can be accurately measured by gated PET simultaneously with the other physiological PET parameters.

Coronary Disease↗