PubMed Health⌕ Search

Biomedical subjects

H L Journée

Publications and source records attributed to H L Journée.

At least 19 recordsLinked to original sources

Influence of electrode impedance on threshold voltage for transcranial electrical stimulation in motor evoked potential monitoring.

Motor potentials evoked by transcranial electrical stimulation (TES) are used for monitoring the motor pathways, with emphasis on the spinal cord and brainstem. The stimulus voltage threshold is the voltage below which no motor response can be elicited. It has frequently been used as a monitoring parameter. However, its value can be limited, because it is affected by the impedance of the stimulus electrode. For example, the voltage threshold can change owing to formation of oedema of the scalp. The relationship between the TES voltage threshold and the electrode impedance of different electrode types was studied and discussed in the context of neuromonitoring: 323 impedance and voltage threshold pairs were studied, and TES was performed with disc cup EEG electrodes (six), corkscrew electrodes (type I: seven, type II: eight), multiple EEG needle electrodes (16) and a large needle electrode Cz' (anode) together with a ground strip over the forehead (cathode) (286). The study found the voltage threshold to be strongly dependent on electrode impedance when the impedance was higher than 460 omega (correlation: R2=0.87; p < 0.001). Below 460 omega, which included 91% of the category with the largest electrode surfaces, 25% of the multiple EEG electrodes and 75% of type II corkscrew electrodes, no significant correlation (R2=0.0064; p=0.15) was found. It was concluded that the correlation between the TES voltage threshold and electrode impedance can be markedly reduced by using TES electrodes with large contact surfaces, resulting in limit values for these parameters. This also may improve the reliability of TES motor evoked potential monitoring.

Electric Impedance↗

Improved neuromonitoring during spinal surgery using double-train transcranial electrical stimulation.

Motor evoked potentials (MEPs) evoked by transcranial electrical stimulation (TES) have become an important technique for monitoring spinal cord function intra-operatively, but can fail in some patients. A new technique of double-train stimulation is described. A multipulse transcranial electrical stimulus is preceded by a preconditioning pulse train that leads to larger MEP responses. An MEP monitoring system was adapted for double-train transcranial stimulation (DTS). MEP responses from 160 anterior tibial muscles obtained by double-train stimulation were analysed. All patients received propofol/remifentanil/O2/N2O anaesthesia. Fifty-two (83%) out of 63 single-train tibial MEPs with response amplitudes below 100 microV were magnified to over 100 microV, with an inter-train (inter-stimulus) interval ITI = 10-35 ms. These 63 amplitudes were magnified by an overall logarithmic mean factor of 15.5. For 97 MEPs with amplitudes above 100 microV, the logarithmic mean facilitation factor was 2.4. It was concluded that double-train TES stimulation can markedly facilitate responses to a single stimulus train (STS). The facilitation appears to be most effective when the responses to STS would otherwise be small or absent. This preconditioning stimulation technique is therefore useful when an STS leads to responses that are too small for effective monitoring.

Electric Stimulation↗

A new application of TCE-MEP: spinal cord monitoring in patients with severe neuromuscular weakness undergoing corrective spine surgery.

The importance of spinal cord monitoring during corrective scoliosis surgery is widely acknowledged. However, for patients with preoperative neurologic deficits, its use is technically difficult. In this article, we describe intraoperative transcranial electrical motor evoked potential (TCE-MEP) monitoring in nine patients with neuromuscular weakness who underwent corrective scoliosis surgery. In each patient, eight muscle groups were recorded and stable responses were obtained in all patients. We conclude that TCE-MEP permits monitoring of the spinal cord in patients with disturbed motor function.

Adolescent↗

Design and application of sensor for recording sounds over human eye and nose.

The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during voluntary breathing, during eyeball movements and during sustained orbicular muscular contractions. Furthermore, measurements are performed at the side of the nose. Major features of the hydrophonic transducer are high sensitivity to physiological sounds and a high degree of insensitivity to environmental sounds propagated through the air. It can be concluded that the hydrophone may be useful for the early detection of intracranial aneurysms and also for apnoea detection.

Auscultation↗

Noisy intracranial tumours.

Transorbital sound recordings were obtained from 21 patients with intracranial tumours, 28 patients with intracranial aneurysms and 20 control patients. The group of patients with tumours consisted of 12 patients with gliomas, of whom 6 had low-grade gliomas and 6 had high-grade gliomas, and 9 patients with meningiomas. All patients with gliomas, including the subgroup of patients with low-grade gliomas, as well as patients with aneurysms, had significantly different sound recordings in comparison to control patients. Recordings from glioma patients did not differ significantly from recordings of aneurysm patients. Radiological evaluation of the tumours was performed in order to establish which tumour characteristics were associated with abnormal sound recordings. It was found that the type of tumour, i.e., histology or malignancy grade, was a significant associated factor, whereas other tumour characteristics such as size, mass effect and amount of oedema were not. In conclusion, patients with specific types of intracranial tumours produced abnormal sounds which could not be distinguished from abnormal sounds recorded in patients with aneurysms. These results may be important for the interpretation of sounds recorded for the detection of intracranial pathology, especially for aneurysm screening.

Adult↗

ESTRACE--1: a stethoscope for functional checking of electrostimulators and low cost body surface mapping system.

In a project on the mapping of body surface potentials evoked by implanted spinal cord stimulators and transcutaneous electrostimulators, a simple device was developed for use in polyclinical practice for easy checking of the function of these stimulators. The device is an electrical stethoscope and consists of an instrumentation amplifier, bandpass filter, a distortion circuit and a headphone. In vivo measurements demonstrate the generation of an amplitude-dependent tone by the distortion circuit. The apparatus is in many aspects similar to a stethoscope: simple to understand and a practical tool for a fast Go/No-Go test. The device can be optionally connected with a PC and enables body surface mapping documentation within a few minutes.

Adult↗

Stimulation characteristics, complications, and efficacy of spinal cord stimulation systems in patients with refractory angina: a prospective feasibility study.

OBJECTIVES: In a prospective study with a 1-year follow-up we evaluated: (1) the feasibility of a method for the adjustment of spinal cord stimulator (SCS) parameters, (2) complications of SCS, and (3) efficacy of SCS. METHODS: In patients receiving an SCS for severe angina unresponsive to standard therapies, SCS characteristics were evaluated within 1 week and at 4, 14, 26, and 52 weeks after SCS treatment. Step-by-step adjustment of pulse output parameters was performed at the electrode configuration at which paresthesias occurred ("sensory threshold"), covered the anginal area ("adjusted setting"), or provoked pain ("motor threshold"). In addition, the number of anginal attacks and intake of glyceryl trinitrate (GTN) tablets were recorded at regular intervals. RESULTS: Twenty-two patients with either a bipolar (14) or a unipolar (8) system were evaluated. In the 14 patients with bipolar systems, alteration in paresthesias required 26 reprogrammings of the configuration. In the eight patients with bipolar systems who completed the follow-up without lead dislocation, the mean "sensory threshold" was 3.3 V (1.7-5.6), the mean "adjusted stimulation" output was 4.5 V (2.8-7.6), and the mean "motor threshold" was 4.9 V (2.8-7.7) after 4 weeks SCS. The mean stimulation duration per 24 hours was 14.1% (5%-24%), and the mean standardized impedance was 821 omega (748-893) after 4 weeks SCS. The unipolar group demonstrated comparable results. After 1-year follow-up the parameters had not changed significantly. During the 1-year follow-up, 6 of 22 patients experienced lead dislocation that required surgery. In all patients, anginal attacks (P < 0.003) and GTN intake (P < 0.005) were reduced significantly with SCS. The effect lasted during the 1 year. CONCLUSIONS: During a 1-year follow-up, the stimulation parameters did not change significantly in the 16 patients without lead dislocations. Our standardized method appears to be feasible for follow-up of SCS. Moreover, SCS seems to be an effective adjuvant therapy for intractable angina, despite a relatively frequent dislocation of the electrode.

Aged↗

Ultrasound myography: application in nerve conduction velocity assessment and muscle cooling.

A new application of ultrasound for studying muscle twitch induced by electrical stimulation is described and some preliminary results are presented. The method, called "ultrasound myography" (UMG), uses Doppler ultrasound to measure muscle movement velocity. The Doppler signals were measured simultaneously with the electromyography (EMG) signals from the thenar muscle of a healthy subject. Averaged EMG and full-wave rectified UMG responses to repeated electrical stimuli were measured after cooling of the hand and adaptation to room temperature. Latency times over the wrist of cold hands adapted to a surrounding temperature of 8 degrees C were 4.5 ms and 16.9 ms for the EMG and averaged rectified UMG responses, respectively. Both latency times decreased considerably after 1 h adaptation to a room temperature of 21 degrees C:20% for the EMG response and 35% for the UMG response. The conduction velocities of the median nerve in the forearm determined by both methods yield comparable results. The results of both methods are discussed. It is concluded that UMG possibly offers a new method in clinical practice for the assessment of nerve conduction velocities in the forearm, and basically is a new simple-to-use technique for noninvasive analysis of deep biomechanical processes.

Adult↗

The acoustic detection of intracranial aneurysms: a clinical study.

A new recording method for the acoustical detection of intracranial aneurysms is presented. A study examining the capability of the method to discriminate between patients with an aneurysm and control patients by a simple, objective parameter is reported. Sound signals were recorded over the eyes, and a real-time spectral analysis was performed on these signals. For this study, recordings performed on 26 patients with an aneurysm were compared with recordings on 26 age- and sex-matched control patients without intracerebral abnormalities. As a result of measures taken to reduce artifacts and to improve the signal-to-noise ratio, the measurements were performed reliably, with little inconvenience for the patients; all measurements could be used for analysis. The power spectra measured in the control patients showed a typical, smoothly descending pattern; those measured in the aneurysm patients clearly differed from this pattern, showing peaks of varying width, height, and dominant frequency. For the objective judgment of the power spectra, the power median is introduced. The sensitivity and specificity of this parameter were determined. Possible methods to improve the results will be discussed.

Adult↗

Sympathetic dysfunction in patients with persistent pain after prolapsed disc surgery. A thermographic study.

Vasomotor function in the lower limbs was tested by means of thermography in 48 patients with and without residual complaints after surgery for a prolapsed intervertebral disc. There is a definite correlation between the severity of the complaints and the thermographic responses which corresponds well with the evidence for a sympathetic reflex dystrophy of the legs (causalgia).

Adult↗

Tumours of the thalamic region. A retrospective study of 27 cases.

Twenty seven patients with thalamic tumours were evaluated retrospectively in the Neurosurgical Clinic of the University Hospital in Groningen between 1969 and 1983. The diagnosis was based on neuroradiological studies. The authors recommend stereotactic biopsy of thalamic tumours followed by irradiation in selected cases.

Adolescent↗