PubMed Health⌕ Search

Biomedical subjects

H L Kisacik

Publications and source records attributed to H L Kisacik.

7 recordsLinked to original sources

Obesity is associated with impaired coronary collateral vessel development.

BACKGROUND: Chronic myocardial ischaemia due to coronary artery stenosis or occlusion has been shown to increase the growth of coronary collateral circulation. Collateralization leads to increased oxygen delivery to the area at risk and hence may reduce ischaemia, prevent infarction and preserve contractile function. However, there is considerable variation among patient subsets in terms of the presence or degree of collateralization. We aimed to evaluate the relationship between obesity and coronary collateral development in patients with ischaemic heart disease. METHODS AND RESULTS: In all, 215 patients (mean age, 57.8+/-8.9 y) with body mass index (BMI)> or =30 kg/m(2) were enrolled into our study. A total of 90 age- and sex-matched patients (mean age, 58.7+/-10 y) with BMI<25 kg/m(2) and significant coronary artery disease were selected as a control group. The mean age and distribution of risk factors for coronary heart disease were not significantly different between two groups other than poorer HDL cholesterol and triglyceride profile in obese patients. The mean BMI was significantly higher in the patient group (33.3+/-2.4 vs 22.8+/-1.7, P<0.001). The mean number of diseased vessels and maximum lesion severity were not significantly different between the two groups. The mean Rentrop collateral score of the patient group was significantly worse than the control group (1.08+/-0.68 vs 2.10+/-0.72, P<0.001). CONCLUSIONS: Our findings suggest that collateral vessel development is poorer in obese patients (defined as BMI> or =30 kg/m(2)) with ischemic heart disease compared to normal range BMI, and the risk of having poor collateral vessel development is significantly increased. However, this might be reflecting the cluster of risk factors, associated with metabolic syndrome, in which insulin resistance plays a major role.

Age Distribution↗

Persisting fever in a patient with brucella endocarditis: occult splenic abscess.

Brucella endocarditis, despite its high mortality rate with combined medical and surgical treatment, has a low occurrence rate in cases of brucellosis and has been endemic in regions surrounding Turkey. Rarely, patients with infective endocarditis with common microorganisms develop a splenic abscess. A patient is reported on with brucella endocarditis and persistent fever. An occult splenic abscess was found. This is the second reported case in the literature of brucella endocarditis with splenic abscess.

Abscess↗

Complications associated with percutaneous placement of intra-aortic balloon counterpulsation: can unsheathed insertion reduce limb ischaemia?

Complications related to percutaneous placement of intra-aortic balloon pump counterpulsation are still high despite major refinements in catheter design and techniques. One hundred and forty-eight patients in whom intra-aortic balloon pumping was inserted were classified into two groups on the basis of the insertion technique. Group I included 103 patients in whom the conventional percutaneous insertion was used. A sheathless insertion technique was used in group II (n = 45). The overall complication rate was 16.6% (25 of 150), in which lower limb ischaemia was the most common complication. The limb ischaemia was noted in 12 patients (11.5%) in group I and 4 patients (8.9%) in group II (statistically not significant). Peripheral vascular disease, diabetes mellitus and female gender were found to be significant predictors of limb ischaemia (p = 0.01, p = 0.02 and p = 0.03, respectively). In conclusion, sheathless insertion of intra-aortic balloon pump catheters does not reduce the incidence of limb ischaemia.

Adult↗

UHL's anomaly.

Uhl's anomaly is a rare congenital hypoplasia of the right ventricular (RV) myocardium. It can be seen together with some other congenital anomalies. Here we first report a 16-year-old male patient with Uhl's anomaly which appears with cardiac tamponade.

Adolescent↗

Comparison of exercise stress testing with dobutamine stress echocardiography and radionuclide ventriculography for diagnosis of coronary artery disease.

Dobutamine stress echocardiography, Tc-99m radionuclide ventriculography (RNVG), and exercise stress testing were performed prospectively in 63 patients with suspected coronary artery disease to compare the values of exercise testing, dobutamine stress echocardiography and RNVG in the non-invasive diagnosis of coronary artery disease. The sensitivities of dobutamine stress echocardiography and RNVG were found to be higher than that of exercise testing (93-62%, p < 0.001; 83-62%, p < 0.05). The sensitivities of dobutamine stress echocardiography and RNVG were similar (p > 0.05). There were no differences between the sensitivities of the three techniques in multiple vessel disease (p > 0.05). The specificities of dobutamine stress echocardiography and RNVG were higher than that of exercise testing (for both of the tests 86-62%, p < 0.05). The diagnostic accuracy of dobutamine stress echocardiography and RNVG were similar (p > 0.05). The results of dobutamine stress echocardiography RNVG were concordant with each other in 46 patients (76%, kappa = 65%) in sectional analysis. Dobutamine stress echocardiography and RNVG tests were comparable with each other in 85% of the 189 segments (kappa = 64%). The expected 5% decrease at peak doses of dobutamine was not detected in stress echocardiography in 25 patients and in RNVG in 26 of the patients. Dobutamine stress echocardiography and RNVG are superior to exercise testing in the diagnosis of single vessel disease and there is no significant difference between the two techniques. When the ejection fraction is considered in dobutamine stress echocardiography and RNVG, it does not make an additional contribution to the diagnosis of coronary artery disease.

Adult↗

Comparison of exercise stress testing with dobutamine stress echocardiography and exercise technetium-99m isonitrile single photon emission computerized tomography for diagnosis of coronary artery disease.

To compare the value of exercise electrocardiography with dobutamine stress echocardiography and exercise technetium-99m isonitrile single-photon emission computed tomography for coronary artery disease, 70 patients with either suspected or proven coronary artery disease underwent dobutamine stress echocardiography, exercise technetium-99m isonitrile single-photon emission computed tomography (mibi-SPECT) and treadmill exercise electrocardiography (ECG). Dobutamine echocardiography and exercise mibi-SPECT revealed a higher overall sensitivity than exercise testing (90 vs 57%, p < 0.001; 96 vs 57%, p < 0.001, respectively). Dobutamine stress echocardiography showed a higher specificity than both exercise mibi-SPECT and treadmill exercise electrocardiography (90 vs 71%, p > 0.05; 90 and 62% p < 0.05, respectively) but the difference between dobutamine stress echocardiography and exercise mibi-SPECT was not statistically significant. Diagnostic accuracy of dobutamine stress echocardiography and exercise mibi-SPECT was higher than that of exercise testing (90 vs 59%, p < 0.001; 89 vs 59%, p < 0.001, respectively). Dobutamine stress echocardiography and exercise mibi-SPECT have superiority over exercise testing in the diagnosis of coronary artery disease and dobutamine stress echocardiography is an alternative for exercise mibi-SPECT.

Adult↗

Comparison of exercise stress testing with simultaneous dobutamine stress echocardiography and technetium-99m isonitrile single-photon emission computerized tomography for diagnosis of coronary artery disease.

The object of our study was to compare the value of exercise stress testing with simultaneous dobutamine stress echocardiography and technetium-99m isonitrile single-photon emission computed tomography for the diagnosis of coronary artery disease. Sixty-nine patients with either suspected or proven coronary artery disease underwent simultaneous dobutamine technetium-99m isonitrile single-photon emission computed tomography and stress echocardiography, and treadmill exercise electrocardiography. Dobutamine echocardiography and technetium-99m isonitrile single-photon emission computed tomography revealed a higher overall sensitivity than exercise testing (94 vs 60%, P < 0.001), but dobutamine stress echocardiography showed a higher specificity than both technetium-99m isonitrile single-photon emission computed tomography and exercise testing (86 vs 64%, P < 0.05, for both tests). In addition, the diagnostic accuracy of dobutamine stress echocardiography and technetium-99m isonitrile single-photon emission computed tomography was higher than that of exercise testing (91 vs 61%, P < 0.001; 86 vs 61%, P < 0.001, respectively). Dobutamine stress echocardiography and technetium-99m isonitrile single-photon emission computed tomography are superior to exercise testing in the diagnosis of coronary artery disease, and dobutamine stress echocardiography can act as an alternative to technetium-99m isonitrile single-photon emission computed tomography.

Adult↗