PubMed Health⌕ Search

Biomedical subjects

H L Manning

Publications and source records attributed to H L Manning.

24 records · Page 2Linked to original sources

Effect of chest wall vibration on breathlessness in normal subjects.

This study evaluated the effect of chest wall vibration (115 Hz) on breathlessness. Breathlessness was induced in normal subjects by a combination of hypercapnia and an inspiratory resistive load; both minute ventilation and end-tidal CO2 were kept constant. Cross-modality matching was used to rate breathlessness. Ratings during intercostal vibration were expressed as a percentage of ratings during the control condition (either deltoid vibration or no vibration). To evaluate their potential contribution to any changes in breathlessness, we assessed several aspects of ventilation, including chest wall configuration, functional residual capacity (FRC), and the ventilatory response to steady-state hypercapnia. Intercostal vibration reduced breathlessness ratings by 6.5 +/- 5.7% compared with deltoid vibration (P less than 0.05) and by 7.0 +/- 8.3% compared with no vibration (P less than 0.05). The reduction in breathlessness was accompanied by either no change or negligible change in minute ventilation, tidal volume, frequency, duty cycle, compartmental ventilation, FRC, and the steady-state hypercapnic response. We conclude that chest wall vibration reduces breathlessness and speculate that it may do so through stimulation of receptors in the chest wall.

Adult↗

Dyspnea: a sensory experience.

Dyspnea--an unpleasant or uncomfortable awareness of breathing or need to breathe--is a common symptom of patients with cardiopulmonary disease. Although often thought of as a single symptom, dyspnea probably subsumes many sensations. Experimental conditions used to induce dyspnea are characterized by discrete groups or clusters of descriptive phrases. Similarly, as the language of dyspnea is refined further, different disease states may be distinguishable by the nuances of breathlessness described by patients. Evidence is gathering that the sensations of dyspnea are modified by information from a variety of receptors throughout the respiratory system. The sense of effort, although still important in the breathlessness associated with mechanical loads, is insufficient to explain the dyspnea arising from a number of experimental and clinical conditions. As our understanding of the interactions between effort and afferent information from the respiratory system grows, new therapeutic interventions to alleviate dyspnea are likely to follow.

Dyspnea↗

New medium for isolating iron-oxidizing and heterotrophic acidophilic bacteria from acid mine drainage.

A new solid medium is described for growing iron and heterotrophic bacteria from acid mine drainage (AMD). Examination of AMD from five states revealed several kinds of colonies of iron-oxidizing bacteria: (i) smooth, (ii) smooth with secondary growth sectors or branching, (iii) star-shaped, (iv) radiating lobe, and (v) flat-rough. All AMD samples yielded whitish colonies that could not use ferrous iron, sulfur, or hydrogen, nor could they grow on nutrient agar, brain heart infusion agar, or Trypticase soy agar. Glucose and sucrose supported growth if the sugar-salts medium was at pH 3.0. The new iron medium has several advantages over others: (i) easy preparation, (ii) rapid growth, (iii) larger colonies, (iv) differentiation of colony morphology, and (v) detection of a new group of heterotrophic acidophilic bacteria.

Culture Media↗

A K alpha dual energy x-ray source for coronary angiography.

The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 lines of lanthanum excited by a high-energy electron beam and the other using the K alpha lines of barium and cerium, were studied. A Monte Carlo electron-photon simulation was used to calculate x-ray spectra and energy deposition profiles from targets of these elements bombarded by electrons in the energy range 140 keV to 1 MeV. A general dual-energy imaging model was developed that used these calculated source spectra to numerically investigate the dependence of the subtraction image signal-to-noise ratio on such factors as the ratio of K-line to x-ray continuum yield, continuum spectral shape, x-ray filtering, and detector response. A signal averaging technique for enhancing the signal-to-noise ratio was also evaluated. The results of these calculations were used to identify an optimum electron beam, target, filter, and detector configuration. A compact electron accelerator capable of providing the required electron beam parameters was designed. Calculations indicate that under ideal conditions the optimized system would be capable of imaging 2 mg/cm2 of iodine contrast agent in 20 g/cm2 of tissue with a signal-to-noise ratio of 5, a detector pixel size of 0.25 mm2, and a total image acquisition time of 10 ms. These parameters are consistent with those needed to image the human coronary arteries after an intravenous injection of iodine contrast agent. These capabilities, along with the relatively modest hardware requirements of this system, make it attractive as an x-ray source for dual energy transvenous coronary angiography.

Computer Simulation↗

Considerations regarding the application of capillary optics to medical radiography.

The generation of monoenergetic or quasimonoenergetic x-ray spectra has been accomplished by several methods including the use of K-edge filtration, characteristic radiation, crystal monochromators, and multilayer mirrors. In this paper some practical questions are discussed regarding the possibility of obtaining narrow-band spectra using x-ray reflection in glass capillary optics which have been reported recently in connection with the focusing and generation of parallel x-ray beams. Derivation of formulas for double and triple reflection with and without additional K-edge filtration imply that these methods are superior to the use of filtration alone. It is shown that the double reflection scheme is most sensitive to the angular divergence of the beam emanating from the capillary array used to generate the incident parallel beam. Simulations using three reflections predict output spectra which are relatively insensitive to blurring due to angular divergence. A small amount of K-edge filtration in combination with three reflections provides considerable sharpening of the x-ray spectrum. Aside from the spectral selectivity provided by the capillary array, the reduced divergence of the primary transmission may have advantages for scatter rejection in situations where the air gap between the patient and detector is increased by an amount consistent with the resolution requirements of the application. In parallel beam situations, the use of capillary arrays between the patient and detector may also be useful for the rejection of divergent scattered radiation.

Capillary Action↗