PubMed Health⌕ Search

Biomedical subjects

H Leeb

Publications and source records attributed to H Leeb.

At least 19 recordsLinked to original sources

Neutron capture cross section measurement of 151Sm at the CERN neutron time of flight facility (n_TOF).

The151Sm(n,gamma)152Sm cross section has been measured at the spallation neutron facility n_TOF at CERN in the energy range from 1 eV to 1 MeV. The new facility combines excellent resolution in neutron time-of-flight, low repetition rates, and an unsurpassed instantaneous luminosity, resulting in rather favorable signal/background ratios. The 151Sm cross section is of importance for characterizing neutron capture nucleosynthesis in asymptotic giant branch stars. At a thermal energy of kT=30 keV the Maxwellian averaged cross section of this unstable isotope (t(1/2)=93 yr) was determined to be 3100+/-160 mb, significantly larger than theoretical predictions.

Journal Article↗

Inversion of dynamical electron diffraction data including absorption

A method to invert the dynamical diffraction of high-energy electrons inside a crystal, which takes into account absorption, is discussed. It is shown that, working at fixed energy, the projected potentials associated with both the elastic and the absorptive scattering can be uniquely obtained from the scattering matrix. Inversion is possible for any principal orientation of the incident beam. Model examples are given.

Journal Article↗

Retrieval of the projected potential by inversion from the scattering matrix in electron-crystal scattering.

The retrieval of a unique crystal potential from the scattering matrix S in high-energy transmission electron diffraction is discussed. It is shown that, in general, data taken at a single orientation are not sufficient to determine all the elements of S. Additional measurements with tilted incident beam are required for the determination of the whole S matrix. An algorithm for the extraction of the crystal potential from the S matrix measured at a single energy and thickness is presented. The limiting case of thin crystals is discussed. Several examples with simulated data are considered.

Journal Article↗

Three-dimensional morphometry in scanning electron microscopy: a technique for accurate dimensional and angular measurements of microstructures using stereopaired digitized images and digital image analysis.

A method for accurate dimensional and angular measurements of microstructures analysed in the scanning electron microscope is described. The method considers central and parallel projections and involves (a) digital image acquisition of stereopaired images from the scanning electron microscope's photodisplay, (b) generation of 3D-image representations, (c) setting of measuring points in the digitized stereopaired images, (d) computation of exact space coordinates (x/y/z) from the corresponding point coordinates (xL/yL; xR/yR), (e) determination of distances and angles between consecutive corresponding points using vector equations, and (f) transfer of computed data into spreadsheets of the data analysis software using dynamic data exchange with simultaneous graphical display of the frequency distribution of variables. Measurements performed on specimens with known dimensions (grid with 10 microm wide square meshes, polystyrene beads with 0.33 microm diameter) and angles (synthetic crystals of K(Al,Cr)[SO4], CuSO4.5H2O and NaCl) revealed a high accuracy in dimensional as well as angular measurements (total error 1 +/- 0.5%). In Monte Carlo experiments the overall error was found to depend strongly on the size of the measured structure relative to the size of the measurement field (field width).

Image Processing, Computer-Assisted↗