Derivatization in capillary electrophoresis.

In recent years capillary electrophoresis (CE) has been developed into a versatile separation technique, next to gas and liquid chromatography (LC), well suited for the determination of a wide variety of e.g., pharmaceutical, biomedical and environmental samples. The main advantages of CE over chromatographic separation techniques are its simplicity and efficiency. It is well recognized, however, that the sensitivity and selectivity of the detection are relatively weak points of CE. One way to overcome these limitations is the conversion (derivatization) of the analytes into product(s) with more favourable detection characteristics. Although, in principle, almost any detection mode can be combined with a derivatization procedure, in practice, fluorescence monitoring is favoured in most cases. This paper aims to give a short overview on the various reagents that can be used for pre-, post- and on-column derivatization in CE. First, a short introduction is given on CE as an analytical technique, followed by a discussion of the pros and cons of the various modes of derivatization, a comparison of derivatizations in CE with derivatizations in LC, the principles of fluorescence and prerequisites for a good fluorophore and the potential of using diode lasers in combination with a labelling procedure. With respect to the derivatization reagents the emphasis is on the labelling of amino, aldehyde, keto, carboxyl, hydroxyl and sulfhydryl groups.

Amines↗

On-line dialysis solid-phase extraction coupled to capillary electrophoresis.

A fully automated dialysis solid-phase extraction (SPE) sample preparation procedure is coupled on-line to capillary electrophoresis (CE) for the first time. The system is used to determine sulfonamides in serum and urine. The dialysis unit serves to remove proteins and particulate matter. Reconcentration of the analytes is performed with a small SPE column while (in)organic salts and other interferences are removed simultaneously. Finally, the analytes are desorbed and injected, via a homemade interface, into the CE system. Limits of detection (LOD) of 0.05-0.1 and 0.05-0.3 microg/mL are obtained in urine and serum, respectively. The within-day and between-day precisions are in the range of 2-6% and 3-8%, respectively, for a concentration of five times the LOD. The dialysis SPE-CE system was used over a period of six months for the analysis of over 500 serum and urine samples without problems such as clogging of the CE capillary or SPE column.

Body Fluids↗

Development and validation of transient isotachophoretic capillary zone electrophoresis for determination of peptides.

Although capillary zone electrophoresis (CZE) is known for its high resolution power and low mass detection limits, the concentration detection limits are rather poor when ultraviolet absorbance detection is used. To overcome this limitation, several on-column transient isotachophoresis (tITP) protocols have been developed and validated for the determination of both cationic and anionic model peptides, separately. Using this preconcentration method, up to 72% of the capillary can be filled with sample solution, without any loss in resolution. Thus, without any modification of the hardware set-up, the sensitivity is increased about two orders of magnitude. For the model cationic peptides (gonadorelin, angiotensin II) good linearity and reproducibility is observed in the 20 to 100 ng/mL concentration range. For the anionic peptides (N-t-Boc-Pentagastrin and two related peptides), a tITP method was developed using a dynamically coated capillary. The coating was prepared by adding Fluorad FC-135 to the leading electrolyte buffer. In this way a positively charged bilayer was formed on the inside of the capillary, producing an electroosmotic flow towards the outlet using reversed polarity conditions. In this way, acceptable analysis times were achieved. Using the developed tITP method, up to 72% of the capillary can be filled with sample solution as well. The anionic peptides are separated even better than when using CZE conditions. Linearity and reproducibility in the 20-100 ng/mL range proved to be excellent.

Angiotensin II↗

Evaluation of phytic acid as a buffer additive for the separation of proteins in capillary electrophoresis.

The use of phytic acid to improve protein analysis by capillary electrophoresis (CE) is becoming more and more popular. Due to its size and number of negative charges (up to 12) it provides a high ionic strength combined with a low conductance resulting in an efficient decrease of wall adsorption for proteins. Because of its twelve acidic groups, phytic acid can be used as a buffer over a wide pH range (pH 2-11). The limited wall adsorption of proteins using phytic acid-containing buffers is observed for buffers with a pH of 5.5 and higher. With a monoprotic buffer, most of the investigated proteins show wall adsorption at the pH values studied. In case of a phytic acid buffer, wall adsorption is reduced by a factor of 2-4. The use of phytic acid both as a modifier and as a pH buffer results in more pronounced differences between the various protein mobilities compared with the use of monoprotic buffers. As a result this feature can be used to improve resolution in protein separations.

Buffers↗

Particle-loaded membranes for sample concentration and/or clean-up in bioanalysis.

Solid-phase extraction nowadays is a major sample preparation tool. The latest development in this area is the introduction of particle-loaded membranes (membrane-extraction disks). The potential of these extraction membranes in bioanalysis is discussed with respect to recoveries, reproducibility, sensitivity and speed. A comparison is made between liquid-liquid extraction and solid-phase extraction using traditional sorbents and extraction disks, and off-line and on-line techniques. Particle-loaded membranes are available in disks with diameters of 4-90 mm. The 25-90 mm disks are mainly used for off-line extractions of mainly environmental samples, while the 4 mm disks are available in the so-called drug tubes that can be used in the same way as conventional extraction cartridges for the extraction of drugs from biological fluids. The main advantage of using drug tubes is the smaller desorption volume and, therefore, the increased sensitivity. Cutting smaller disks, from the commercially available disks, allows the use of on-line extractions in column-switching systems. The main conclusion is that in many cases particle-loaded membranes are more efficient than packed solid-phase extraction cartridges.

Chemical Fractionation↗

Pre-, on- and post-column derivatization in capillary electrophoresis.

This survey gives a short overview of the various reagents and procedures that can be used for pre-, post- and on-column derivatization in capillary electrophoresis. First there is an introduction about capillary electrophoresis as an analytical technique; this is followed by a discussion of the pros and cons of the various modes of derivatization and a comparison with liquid chromatography. In the following paragraphs the reagents for a number of functional groups are discussed. The emphasis is on derivatization of the amino group. Most of the information on the reagents and derivatization procedures is listed in tables together with information on the detection mode, analytes, sensitivity and samples. In addition to the amino group, information is given on labeling of aldehyde, keto, carboxyl, hydroxyl and sulfhydryl groups.

Amino Acids↗

Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 l samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (> 2 l for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n = 3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 microgram/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10 x 2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 microgram/l in surface water.

Adsorption↗

Determination of the anticancer drug metabolite WR1065 using pre-column derivatization and diode laser induced fluorescence detection.

A liquid chromatographic (LC) procedure using alumina as stationary phase in both the pre- and the analytical column, is reported for the determination of WR1065, the active metabolite of the amino- and thiol-containing anticancer drug WR2721. After pre-column derivatization of the thiol group, the analyte is determined by LC with diode laser induced fluorescence detection in the near-infrared. Selective removal of excess label is achieved by means of column switching; it allows the detection of 5 x 10(-9) M WR1065 in water and 10-fold diluted, deproteinated plasma samples. The detection limit is determined by the derivatization reaction and not by the fluorescence detection of the labelled analyte. Endogeneous thiols do not interfere.

Antineoplastic Agents↗

Automated column liquid chromatographic determination of amoxicillin and cefadroxil in bovine serum and muscle tissue using on-line dialysis for sample preparation.

A fully automated method is described for the determination of amoxicillin and cefadroxil in bovine serum and muscle tissue. The method is based on the on-line combination of dialysis and solid-phase extraction for sample preparation, and column liquid chromatography with ultraviolet detection. In order to enhance the UV detectability of the analytes, post-column addition of 0.1 M sodium hydroxide is performed. The method shows good linearity and repeatability for both analytes in serum as well as in muscle tissue; the limits of detection in these samples are 0.05 microgram/ml and 0.2 microgram/g, respectively. The method has a sample throughput of 30 samples per 24 h.

Amoxicillin↗

General strategies and selection of derivatization reactions for liquid chromatography and capillary electrophoresis.

The general strategies, reasons and the different possibilities for the derivatization of biomedically important compounds are reviewed. Different approaches apply for small versus large analyte molecules, different advantages and disadvantages are visualized with pre- and post-column arrangements. Particular interest is focused upon solid-phase derivatization reagents.

Chromatography, High Pressure Liquid↗

Liquid chromatographic analysis of carboxylic acids using N-(4-aminobutyl)-N-ethylisoluminol as chemiluminescent label: determination of ibuprofen in saliva.

N-(4-Aminobutyl)-N-ethylisoluminol was used for labelling of carboxylic acids. The derivatization reaction was carried out with 1-hydroxybenzotriazole as pre-activator of the carboxylic acid function and N-ethyl-N'-(3-dimethylaminopropyl)carbodiimide as the coupling reagent. Optimum conditions for the derivatization were determined by using factorial design analysis, with ibuprofen as the test compound. Chemiluminescence detection was carried out using a post-column on-line electrochemical hydrogen peroxide generation system and the addition of microperoxidase as the catalyst. The detection limit of derivatized ibuprofen in human saliva was 0.7 ng per 0.5 ml of saliva, with a recovery of 96.1 +/- 1.3%. The method was linear over at least three decades (2.5 ng to 2.5 micrograms) and the repeatability was satisfactory (R.S.D. = 5.2% at the 25 ng level; n = 4).

Blood Proteins↗

Determination of aflatoxin M1 using a dialysis-based immunoaffinity sample pretreatment system coupled on-line to liquid chromatography. Reusable immunoaffinity columns.

A liquid chromatographic column-switching system containing a dialysis unit and an anti-aflatoxin immunoaffinity precolumn (immuno precolumn) is described for the automated determination of aflatoxin M1 in milk samples. Both a flat membrane dialysis unit working according to the flowing donor-flowing acceptor principle and a laboratory made hollow-fibre dialysis unit working according to the stagnant donor-flowing acceptor principle were evaluated. The hollow-fibre unit is superior with respect to repeatability (3% relative standard deviation) and detection limit (10 ng/l for aflatoxin M1 in milk), in spite of the fact that the overall recovery is only 6%. Interfering compounds, which would destroy the activity of the immuno precolumn, are efficiently removed from the system by the dialysis step; a single immuno precolumn can then be used for over 70 milk analyses. No decrease in the performance of either the immuno precolumn or the hollow-fibre dialysis unit is observed.

Aflatoxin M1↗

Determination of oxidized, reduced and protein-bound glutathione in eye lenses by high-performance liquid chromatography and electrochemical detection.

A method for the detection of oxidized, reduced and protein-bound glutathione in eye lenses has been developed. Homogenized lens samples are deproteinated with acetonitrile and perchloric acid. Protein-bound glutathione is reduced by 1,4-dithiothreitol. Separation of the different forms of glutathione and dithiothreitol is performed by ion-pair reversed-phase high-performance liquid chromatography with sodium octylsulphate as the ion-pairing agent. The compounds are detected amperometrically using on-line-generated bromine, which oxidizes thiols and disulphides. In this way two samples can be analysed in triplicate in a single day. The lower detection limits are 80 and 48 nmol per gram wet lens for reduced and oxidized glutathione, respectively. The amounts of free reduced and protein-bound glutathione in calf lenses, determined with this method, are 6.8 +/- 0.4 and 0.96 +/- 0.03 mumol per gram wet lens, respectively. That of oxidized glutathione is less than 0.048 mumol per gram wet lens.

Animals↗

Evaluation of eluents in thermospray liquid chromatography-mass spectrometry for identification and determination of pesticides in environmental samples.

The influence of different eluents in positive and negative ion mode thermospray liquid chromatography-mass spectrometry was studied with several groups of pesticides, including carbamates, chlorotriazines, phenylureas, phenoxy acids and organophosphorus and quaternary ammonium compounds, and the corresponding degradation products. Using the positive ion mode in combination with reversed-phase eluents the base peaks generally corresponded either to [M + H]+ for the chlorotriazines and their hydroxy metabolites or to [M + NH4]+ for the carbamates, the phenylureas, the organophosphorus pesticides and their oxygen analogues. In the negative ion mode different processes such as (dissociative) electron-capture and anion attachment mechanisms occurred. Fragment ions such as [M - CONHCH3]- for the carbamates, [M - H]- for the chlorotriazines, phenylureas and chlorinated phenoxy acids and [M].-, [M - R]- (R being a methyl or ethyl group) for organophosphorus pesticides were usually formed. Depending on the eluent additive used (ammonium acetate, ammonium formate and/or chloroacetonitrile), three different adduct ions were formed: [M + CH3COO]-, [M + HCOO]- and [M + Cl]-. Normal-phase eluents with cyclohexane, n-hexane and/or dichloromethane provided more structural information and enhanced the response of several compounds. The positive ion mode was useful for the detection of chlorinated phenoxy acids and chlorophenols which could not be detected in the positive ion mode using reversed-phase systems. The base peaks generally corresponded to [M].+, [M + H]+ or [M - Cl]+. For the characterization of difenzoquat, a quaternary ammonium pesticide of which trace level analysis is troublesome, a post-column ion-pair extraction system was used. An aqueous mobile phase with a sulphonate-type counter ion was applied and an extraction solvent containing cyclohexane-dichloromethane-n-butanol (45:45:10) was used in thermospray liquid chromatography-mass spectrometry. Illustrative examples of the determination of residue levels of pesticides in soil matrices are shown.

Carbamates↗

On-line immunoaffinity sample pre-treatment for column liquid chromatography: evaluation of desorption techniques and operating conditions using an anti-estrogen immuno-precolumn as a model system.

An immunoaffinity precolumn (immuno-precolumn) containing an immobilized antibody directed against estrogen steroids, was used as a model system for the evaluation of different desorbing techniques, suitable for on-line coupling to column liquid chromatography (LC). Desorption of estrogen analytes from the immuno-precolumn proved to be impossible with the buffers and chaotropic solutions frequently used in affinity desorption. Micellar solutions are effective in obstructing the antibody-antigen reaction, but their use as desorbing solutions was not found to be practical because of the large interferences introduced into the chromatograms. Desorption with aqueous solutions at elevated temperature, created by microwave action or conventional heating, although effective is not practical in this instance, because the agarose used in this study as the stationary phase for the immuno-precolumn is prone to heat decomposition. The most effective and practical approach is desorption with a methanol-water mixture (95 + 5 v/v). On-line dilution of the eluate allows the concentration of the desorbed analytes using a reversed-phase LC system with subsequent separation and ultraviolet detection. The performance of the system with spiked urine and plasma samples, which were introduced directly into the system, was evaluated and the results were compared with immunoselective desorption.

Antibodies↗

Liquid chromatographic determination of pentachlorophenol in serum, using pre-column phase-transfer catalysed dansylation and post-column photolysis with fluorescence detection.

Dansylation of pentachlorophenol was carried out after solid-phase extraction of acidified human serum and desorption with dichloromethane, in a dichloromethane-water two-phase system using tetrabutyl-ammonium bromide as the phase-transfer catalyst. Derivatisation was complete within 2 min at room temperature. After evaporation of an aliquot of the organic phase, the residue was dissolved in methanol and injected into a reversed-phase chromatographic system, equipped with a post-column photochemical reactor. In the reactor, dansylated pentachlorophenol is converted into highly fluorescent products. The recovery of the analyte from serum was 85 +/- 4%. Calibration graphs for horse and human serum were linear over two decades, with correlation coefficients ranging from 0.996 to 0.999. The detection limit of pentachlorophenol in horse and human serum was 400 pg ml-1. The reproducibility of the total procedure for a human serum sample containing 4 ng ml-1 was 4.5%.

Catalysis↗

Post-column reactors for sensitive and selective detection in high-performance liquid chromatography: categorization and applications.

The increasing interest in the rapid trace analysis of large series of biomedical samples using column liquid chromatographic techniques requires the use of well balanced combinations of sample pretreatment, separation and detection techniques. In such work, selectivity, sensitivity and reproducibility are the key parameters. The application of automated or semi-automated on-line pre-column technology and/or post-column reaction detection are excellent ways to meet these requirements. A critical review is presented of the theoretical background of on-line post-column reactors with emphasis on their categorization, viz., open-tubular, packed-bed, segmented-stream and hollow-fibre membrane reactors. The evaluation of these reactor systems is performed by discussing selected applications of, for instance, systems based on electrochemical and redox, hydrolytic, photochemical, ion-pairing, true chemical derivatization, peroxyoxalate chemiluminescence and solid-phase reactions. As automation is becoming even more important, a number of labelling procedures, which can be performed in an on-line pre-column mode, are briefly discussed and a comparison is made between the potential of on-line pre- and post-column procedures.

Chemistry, Clinical↗

Reversed-phase ion-pair analysis of 5-fluorouracil in pig bile, liver homogenate, plasma and urine after administration by isolated liver perfusion.

5-Fluorouracil is at present one of the most administered cytostatic drugs in cancer chemotherapy. However, due to its high toxicity, local administration of the drug, e.g. by isolated liver perfusion, may be advantageous. A bioanalytical procedure, suitable for the routine analysis of 5-fluorouracil in pig bile, liver homogenates, plasma and urine is described using reversed-phase ion-pair chromatography with absorbance detection at 268 nm. Using a protein precipitation procedure with acetonitrile, a determination limit of 3500 ng g-1 was achieved for liver samples, and 5 ng ml-1 for plasma samples using a liquid-liquid extraction step.

Animals↗