Methods of implantable cardioverter-defibrillator-pacemaker insertion to avoid interactions.

Experience with combined transvenous pacemaker and implantable cardioverter-defibrillator insertion in 21 patients is described. Special techniques are needed to avoid potentially lethal pacemaker-implantable cardioverter-defibrillator interaction. Separation between leads for the two devices should be maximized. The electrophysiologic criteria for successful device function can be met, even when some leads for both devices must be placed by a transvenous approach.

Arrhythmias, Cardiac

Computer visualization of left ventricular geometry during the cardiac cycle.

Mathematical expressions regulating ventricular dimensions during the cardiac cycle have been defined. Classical, static images are limited in comparison with ventriculograms, are not intuitive for teaching, and do not effectively convey effects of hypertrophy or dilatation. Accordingly we developed Tachycardia, an interactive menu-driven graphics program. The program allows three-dimensional visualization of the kinetics of the thick-walled, ellipsoidal left ventricle (LV). The user may specify mass, ejection fraction, end-diastolic volume, major to minor axis ratio, and diastole to systole time ratio. Real-time animation of heart rates ranging from 50-150/min is achieved. A library contains animations representing the normal LV, including dilatation and concentric or eccentric hypertrophy. For comparison of differences in LV geometry among ventricles, multiple animations can be viewed simultaneously. We conclude that computerized animation provides an intuitive understanding of the dynamic geometry of the cardiac cycle. User definition of the visualization can provide clinical utility and teaching value.

Computer Graphics

Permanent pacing following cardiac transplantation.

Permanent pacemakers were inserted in 20 of 439 patients who had received 453 orthotopic cardiac allografts since 1980 at the Columbia-Presbyterian Medical Center. Mean age at transplantation was 45 +/- 4 (SEM) years (range 10 to 64). Pacemakers were inserted an average of 2.4 +/- 1 months after transplantation (range 0.4 to 29), 16 of 20 (80%) within the first month. Indications included sinus bradycardia or sinus arrest in 15 (75%), third-degree heart block in 2 (10%), and both sinus node and atrioventricular node dysfunction in 3 (15%). Rejection episodes and pacemaker insertion were associated in 8 patients (40%). Pacing modes included DDD (7 patients, 35%), AAI,R (7 patients, 35%), VVI,R (3 patients, 15%), DDD,R (2 patients, 10%), and VVI (1 patient, 5%). There was no pacing-related morbidity or mortality. Fourteen of 20 patients (70%) are alive and well 3 to 48 months (mean 24 +/- 4) after transplantation. Late follow-up indicated that atrioventricular node dysfunction resolved in one of two patients, sinoatrial node dysfunction improved or resolved in 7/13 patients, and no atrioventricular block developed in 11 (8 to 37 months, mean 22 +/- 3). Permanent pacing can be safely performed following orthotopic cardiac transplantation, predominantly for sinus node dysfunction. The requirement for pacing may reflect ongoing or new onset rejection and patients should therefore be evaluated accordingly. Dual-chamber pacing is probably not necessary unless atrioventricular node dysfunction is coexistent. Further, as most transplant recipients return to an active life-style, AAI,R may be the preferred mode of pacing.

Adolescent

Effects of crystalloid, blood, and University of Wisconsin perfusates on weight, water content, and left ventricular compliance in an edema-prone, isolated porcine heart model.

Coronary perfusion with blood and cardioplegic solutions was examined in isolated, arrested, hypothermic porcine hearts. Myocardial water content, heart weight, and left ventricular diastolic pressure-volume curves were measured before and after coronary perfusion. Statistics were based on exponential curve fitting to pressure-volume data and analysis of variance. Thirty-two pig hearts were divided into five experimental groups and a control group; after control measurements, each experimental group underwent three successive coronary perfusions with 1 L of unmodified blood or a solution of controlled osmolarity, 150 mOsm/L (diluted Plegisol solution), 280 mOsm/L (Plegisol solution and albumin), 334 mOsm/L (University of Wisconsin solution), or 380 mOsm/L (Stanford solution). After each perfusion, measurements were repeated. All experiments were completed within 90 minutes. The first perfusion was delayed 20 minutes after excision of the heart to allow for instrumentation. Each experimental group demonstrated a statistically significant increase in heart weight and myocardial water content and a significant decrease in left ventricular compliance after perfusion. Changes were less pronounced with blood than crystalloids. Edema effects were minimized but not prevented by hyperosmolarity. University of Wisconsin solution appeared unique in minimizing progressive edema after the first perfusion. Over the 81 perfusions studied, changes in left ventricular compliance were linearly related to heart weight and water content. We conclude that in this model, in which edema sensitivity is increased by delayed perfusion and venous occlusion, edema is minimized but not eliminated by whole blood and University of Wisconsin solution. The model appears useful in assessing properties of cardioplegia vehicles intended for use in the injured myocardium.

Adenosine

Effect of AICD patch electrodes on the diastolic pressure-volume curve in pigs.

Although the automatic implantable cardioverter defibrillator (AICD) is effective against malignant ventricular arrhythmias, the effects of AICD patches on left ventricular diastolic properties have not been defined. Accordingly, extrapericardial (group E, n = 5) or intrapericardial (group I, n = 6) AICD patches were implanted through a median sternotomy in 11 anesthetized pigs. Six weeks later, using a left thoracotomy, the hearts were arrested with hypothermic cardioplegia. A balloon catheter was inserted into the left ventricle through the aortic root, and pressure-volume curves were measured before and after sequential removal of patches and pericardium. A dense intrapericardial fibrotic reaction in group I was not present in group E. Normalized left ventricular filling volumes in group E were significantly larger at pressures of 5.1 to 10, 15.1 to 20, and 20.1 to 28 mm Hg compared with group I (p less than 0.05). We conclude that intrapericardial AICD patches adversely affect left ventricular diastolic pressure-volume relations and recommend that AICD patches be placed in the extrapericardial location clinically whenever possible.

Animals

Transvenous pacemakers in children: relation of lead length to anticipated growth.

Although transvenous pacing is feasible in infants and children, uncertainty remains as to how to allow for future growth at the time of lead insertion. Accordingly, we retrospectively reviewed the relation between age and transvenous lead length. Standard posteroanterior chest roentgenograms were reviewed for 26 patients with transvenous pacemakers inserted at Babies Hospital and Presbyterian Hospital between 1985 and 1989. Sixteen of these were children (age range, 0.75 to 15 years) and 10 were adults (age range, 27 to 90 years). The intravascular length of right ventricular pacing leads was measured as projected on the roentgenogram. In 10 children, the presence of lead loops in the right atrium required the lead length that would have resulted from conventional placement to be estimated. Results for right ventricular pacing lead lengths were correlated with age using linear regression analysis. Average uncorrected lead length measured on the roentgenogram was 345 +/- 35 mm (standard deviation) in adults and 222 +/- 51 mm in children. The use of right atrial loops increased implanted lead length by an estimated 79 mm, from 188 +/- 26 to 267 +/- 43 mm. The difference between lead length in children and adults was analyzed. Approximately 190 mm of additional right ventricular pacing lead in infants and 100 mm in 10-year-old children was needed for growth to adult size. We conclude that an 80-mm right atrial lead loop will allow 6 to 12 years (mean, 8 years) of growth in infants and children without the need for reoperation to adjust lead length.

Adolescent

Transvenous pacing in infants and children with congenital heart disease.

A technique for transvenous pacemaker implantation in children with complex heart disease is described. The use of small positive-fixation leads, introducers, retained guidewires, and atrial lead loops to allow for growth all have an important role in management of this often challenging problem.

Cardiac Catheterization

Simulated left ventricular aneurysm and aneurysm repair in swine.

Patch reconstruction of left ventricular aneurysm may be superior to linear closure, but this hypothesis has not been tested experimentally. Accordingly, six anesthetized domestic pigs were instrumented to measure regional left ventricular wall thickening, stroke volume, systolic left ventricular pressure, and myocardial oxygen consumption. With total bypass and cardioplegia, a 6 by 8 cm Dacron patch was inserted into the anteroapical left ventricle. Simulations were as follows: left ventricular aneurysm, patch open; patch reconstruction, 50% patch plication; standard repair, ventriculotomy edges approximated. Global function, from stroke work (stroke volume x integral of left ventricular pressure)-left ventricular end-diastolic pressure curves, was depressed in all three simulations compared with control. A tendency for stroke work to be greater for standard repair than for left ventricular aneurysm and patch reconstruction at higher preloads was not statistically significant. Mechanical efficiency, from stroke work/myocardial oxygen consumption (joules per milliliter oxygen per beat), was 2.43 +/- 0.52 (mean +/- standard error of the mean) (control), 2.22 +/- 0.94 (standard repair), 1.27 +/- 0.39 (patch reconstruction), and 1.09 +/- 0.37 (left ventricular aneurysm) (no significant differences). Regional work was calculated as regional left ventricular wall thickening x integral of left ventricular pressure. The slope of the regional work-end-diastolic wall thickness relation decreased in the posterior wall 14.0 +/- 2.9 (control) versus 8.4 +/- 2.0 (left ventricular aneurysm), 6.9 +/- 1.4 (patch reconstruction), and 7.4 +/- 1.4 (standard repair) (p less than 0.05). In the anterior wall, contractility did not change significantly (7.4 +/- 1.2, control; 7.8 +/- 2.7, left ventricular aneurysm; 5.0 +/- 0.4, patch reconstruction; and 5.3 +/- 0.4, standard repair). Decreased end-diastolic wall thinning anteriorly suggested tethering. These results in the normal left ventricle suggest that patch ventriculoplasty is of no greater benefit than linear repair. Either repair may impede function of adjacent myocardium through restriction of regional diastolic lengthening.

Animals

Long-term function of human cardiac allografts assessed by two-dimensional echocardiography.

Previous studies from our laboratory demonstrated increasing left ventricular mass in cyclosporine-treated cardiac allograft recipients over 30 days after transplantation, but the long-term evolution of this process and possible effects on allograft function are unknown. Accordingly, quantitative two-dimensional echocardiography was performed 2 and 23 days and 15 months postoperatively in 14 recipients treated with cyclosporine and prednisone. Changes in left ventricular ejection fraction, end-diastolic volume, mass, and end-systolic wall stress were analyzed. Comparison of studies at 2 and 23 days revealed significant (p less than 0.01) increases in ejection fraction (54% +/- 8% [standard deviation] to 62% +/- 4%), end-diastolic volume (84% +/- 32 ml to 96 +/- 31 ml), and left ventricular mass (118 +/- 45 gm to 136 +/- 41 gm). Comparison of studies at 23 days and 15 months revealed no significant change in end-diastolic volume or left ventricular mass, whereas ejection fraction decreased slightly (62% +/- 4% to 57% +/- 4%, p less than 0.01). End-systolic wall stress decreased when data at 2 days and 15 months were compared (83 +/- 24 gm/cm2 versus 66 +/- 18 gm/cm2, p less than 0.05), but no change in contractility was apparent from the ejection fraction/end-systolic stress relation. We conclude that left ventricular mass and end-diastolic volume increase early after transplantation in cyclosporine-treated cardiac allograft recipients, but these changes are not predictive of long-term results, which are characterized by no significant late variation in left ventricular mass, end-diastolic volume, or contractility.

Adolescent

Pharmacologic antagonism of beta-adrenergic blockade in dogs. I. Hemodynamic effects of isoproterenol, dopamine, and epinephrine in acute propranolol administration.

Hemodynamic effects of isoproterenol, dopamine, and epinephrine were studied before and after acute beta-adrenergic blockade in 16 open-chest, anesthetized mongrel dogs. Beta blockade was induced with 1 mg. per kilogram of intravenous propranolol. Cardiac output measurements were obtained by thermal dilution, and pressure recordings were obtained in the right ventricle, pulmonary artery, left atrium, left ventricle, and aorta. Derived parameters included stroke volume, pulmonary and systemic vascular resistances, and peak left ventricular dP/dt. In the presence of propranolol, epinephrine became a lethal drug in large doses and did not increase cardiac output in standard doses. Dopamine, in 25 to 50 mcg. per kilogram per minute doses, increased arterial pressure and systemic resistance; cardiac output was diminished compared with dopamine, 10 mcg. per kilogram per minute, prior to propranolol, as a result of increased resistance and decreased LV contractility. Isoproterenol, 0.6 to 0.9 mcg. per kilogram per minute, 15 to 20 times standard dosages, had moderately positive inotropic effects and increased cardiac output. Left ventricular systolic pressure with isoproterenol after propranolol was reduced when compared with effects of smaller doses prior to propranolol. These observations suggest that none of the catecholamines studied would be optimal for circulatory support in heart failure in the presence of propranolol. The present results define a pharmacologic basis for design of appropriate drug combinations for circulatory support in beta-blocked animals.

Adrenergic beta-Antagonists