PubMed HealthSearch

Biomedical subjects

H Nakamae

Publications and source records attributed to H Nakamae.

3 recordsLinked to original sources

Clinical evaluation of a teleradiology system utilizing personal computers and public telephone line.

Practical usefulness of a teleradiology system using CCD camera, personal computer and telephone line was evaluated in a daily clinical practice. Image quality of this system is diagnostic for the majority of abnormalities on radiological images including plain radiographs. Radiological consultation between hospitals in the same city as well as between distant cities using this moderately priced system was thought to be useful in 90% of cases. Teleradiology using compact systems like ours is expected to be useful in the urban clinical environment as well as in distant areas.

Evaluation Studies as Topic

[Basic study on MRI guided stereotaxic surgery].

In 1987, we started MRI guided stereotaxic surgery using BRW-MRI apparatus. As distortion of image had been noted around the periphery of MRI due to the characteristic static magnetic field, we examined accuracy of data before clinical application. The MRI machine was a MRT-15A, 0.15 Tesla resistive type made by Toshiba. The stereotaxic apparatus consisted of a head ring, which was fixed to the patient's head, a cubical localizer frame which was attached to the head ring for the scanning phase, and a programmed computer. The localizer frame had multitubular channels, which could be fixed and drained easily with whatever paramagnetic fluid was desired. Since the beginning of our use of the instrument, we have used petroleum jelly. This material produced sufficient localizer image for us to fully determine any MRI scan plane. Once the MRI scan target had been identified, it could be approached stereotaxically in a same way as was done in the CT-related one. In the examination, at first, we studied the MRI image of a grid phantom, or the localizer frame placed on the center of the magnetic field. In the MRI, distortion of the image was seen only at the periphery of the Z axis. Secondly, we calculated the three-dimensional coordinates of the center of tumors in axial, coronal and sagittal images for correlation. But, the target values did not differ by over 5.1 mm. Therefore we concluded that the distortion of the image had minimum effect on surgery. Thirteen surgical operations were performed for brain tumors. Among these surgical interventions biopsy alone was performed in 8 cases, and biopsy combined with brachytherapy was performed in 5 cases.(ABSTRACT TRUNCATED AT 250 WORDS)

Brachytherapy