PubMed Health⌕ Search

Biomedical subjects

H O Stolberg

Publications and source records attributed to H O Stolberg.

26 records · Page 2Linked to original sources

Inability of caliper measurement to enhance observer agreement in the interpretation of coronary cineangiograms.

Important clinical decisions are made on the basis of the interpretation of the degree of stenosis in the coronary cineangiogram. Thus, minimization of observer variation (both intra and inter) is crucial. The purpose of this investigation was to determine if measurement of stenotic lesions by caliper (CM) as compared with the usual eyeball method (EM) would reduce observer variation. Five observers, using the AHA scoring system, estimated maximal luminal narrowing in 14 segments on 10 films providing 2 reports on each film by EM and 2 by CM, thus making observations on 2800 segments. This allowed analysis of intraobserver variation for each reporter for method EM and CM, and for interobserver variation by each method. Since chance agreement is an important component in an observational study, a correction for this was made using the Kappa statistic. The results revealed that the mean Kappa by EM was 0.71 compared to 0.63 by CM (1 being perfect agreement and 0 no agreement). Agreement was much greater in proximal rather than distal segments. Interobserver agreement was consistently higher by EM K = 0.62 than CM K = 0.53 (p = 0.0007). A delineation of the types of disagreement and their clinical significance are important considerations in the evaluation of observer variation. It is concluded that the use of a caliper does not enhance either intra or interobserver agreement.

Cineangiography↗

Intracoronary nitroglycerin reversal of life-threatening ergonovine maleate-induced coronary artery spasm.

Ergonovine maleate was given to a patient suspected as a case of Prinzmetal's variant angina following demonstration of normal coronary arteries by angiography. Profound shock, heart block, and severe pain accompanied marked spasm of the left coronary artery. Direct infusion of nitroglycerin into the left coronary artery reversed the spasm when sublingual and intraaortic nitroglycerin failed to prevent further hemodynamic and clinical deterioration.

Angina Pectoris, Variant↗

Relief of coronary artery spasm by nitroglycerin: time-dependent variability in drug action.

The arteriographic distinction between a fixed atheromatous obstruction and localized vasospasm in the coronary artery is often decided by the response of the lesion to nitroglycerin. We studied the time course of nitroglycerin in four patients with coronary artery spasm as revealed by selective angiography. Following complete dissolution of a 0.6 mg tablet of nitroglycerin sublingually a slight increase in heart rate occurred as early as two minutes, variable changes in overall vessel diameter were observed within four minutes, but the localized spasm remained fixed. It was not until six minutes had elasped that reinjection showed disappearance of spasm and uniform patency of the vessel in all cases. These observations stress the importance of waiting an appropriate period of time (at least six minutes) following complete absorption of sublingual nitroglycerin before any conclusion can be rationally drawn regarding the nature of a stenotic lesion as seen angiographically.

Adult↗

Ionic versus nonionic contrast use.

It has taken many years of research, development and intense scientific investigation to produce intravascular contrast media. Research on relations between chemical structure, animal toxicity, and water-solubility has produced a number of highly water-soluble, iodinated compounds for use in diagnostic radiology as intravascular contrast agents. The currently used intravascular agents may be classified into four groups according to their chemical structure: 1. Ionic monomers 2. Ionic monoacid dimers 3. Nonionic monomers 4. Nonionic dimers It is the objective of this publication to review the history and development of intravascular contrast media as well as their properties, general effects and clinical use. The four types of contrast media differ significantly in their chemical structure and physico-chemical properties, and these differences determine their osmotoxicity, chemotoxicity, and ion toxicity. We analyze the organ specific toxic effects of intravascular contrast media upon the central nervous system, the cardiovascular system, and the renal system. We also review the secondary effects, clinical manifestations, and the incidence of adverse events associated with different types of contrast. The choice of contrast media has become critical since the introduction of nonionic agents because their toxicological and pharmacological properties differ from those of the ionic agents. The application of basic concepts involved in the use of contrast media in excretory urography, computed tomography, angiography, and angiocardiography is discussed, and the advantages of the use of nonionic contrast agents are outlined. Economic and ethical issues are presented with emphasis upon strategies to reduce the risk associated with the injection of intravascular contrast and to curtail consumption according to rational principles of use.

Contrast Media↗

The limited utility of the plain chest film in the assessment of left ventricular structure and function.

The determination of radiographic cardiac size as an estimation of the state of cardiac function is one of the more common correlations made. Despite the widespread use of these measurements, the correlation between cardiac function and radiographic appearance, and the validity of clinical judgments based on this correlation, has not been fully determined. Similarly, the increment in left ventricular chamber size necessary to produce a change in the plain film appearance of the left ventricle has not been defined. The results of a two observer, blind, retrospective analysis of plain film radiographs of the chest, and related quantitative left ventricular angiograms, and left ventricular pressure studies performed on 256 patients is presented. The sensitivity, speficity, predictive value and accuracy of six previously described plain film measurements of left ventricular size together with determinations of the extent of left ventricular volume change necessary to produce a perceptible change in the plain film radiographic appearance of the left ventricle are reported. The performance of each of these measurements proved to be disappointing. A sensitivity of 75% was not possible using any of the methods unless the left ventricular chamber volume was more than 66% above the upper limit of normal.

Cardiac Volume↗

Dying of ignorance.

Explore the source record for details and available documents.

Evidence-Based Medicine↗