Publications and source records attributed to H Obstfeld.

11 recordsLinked to original sources

A study of the accuracy of corneal reflection pupillometers.

We studied the accuracy of nine corneal reflection pupillometers made by three manufacturers, because, at the time of investigation, we could not find any information about their accuracy. For this purpose two steel balls separated by spacer bars, were positioned to simulate nominal inter-pupillary distance (PD) measurements of 55, 60, 65 and 70 mm. Ten measurements of each 'PD' for distance vision, were made by two experienced observers, with each instrument. We found that interobserver differences in measurement were clinically insignificant most of the time, although some data sets were significantly different statistically. The most consistent and accurate measurements of PD were achieved with PD 65 mm. The average error in mean value of the measurements for all PD's, was 2.3 mm, and the average of the standard deviation in our measurements, was 0.26 mm. Significant sources of error were poor eye relief in all instruments evaluated, as well as friction in the scale adjustment mechanism in some instruments. Our findings show that while a given pupillometer may be relied upon to give consistent readings (within the limits of clinically acceptable error), its accuracy should be checked periodically, especially for very small and very large PD measurements.

Humans↗

A study of the accuracy of lens measures.

The accuracy of 26 aged and three new lens measures was investigated. Instruments were applied to surfaces of known curvature employing the conventional, hand-held method as well as while rigged on an optical bench. In addition, using the latter method, a controlled amount of surface tilt was introduced. A large inter-instrument variation in accuracy was encountered. In general, hand-held lens measures were found to provide equally accurate measurements on convex and concave surfaces, with the exception of the -20 D surface, and inclinations from 0 degree to 5 degrees did not result in erroneous measurements. Results for inclinations of 15 degrees became unreliable. The different usages of the instrument are discussed.

Equipment Design↗

Prescribing for presbyopes who use VDUs.

It has been widely assumed that VDU users position their paperwork closer than the screen to their eyes by an amount which may exceed their depth of field. The design and prescription of spectacles for the presbyopic VDU user must take these working distances into account. From theoretical considerations, the focal characteristics of occupational spectacles are matched to combinations of working distances. Measurement of these distances was carried out on a sample of 243 VDU users, 101 of whom were presbyopic and 53 nearing presbyopia. The results were analysed in terms of type of work and accommodative reserve, and compared with previous studies. Contrary to the views of several previous workers, it was found that paperwork did not tend to be positioned closer than the screen to the eyes. This finding was little affected by the type of VDU use or the accommodative reserve of the subject. Special occupational spectacle lens forms are thus not generally indicated for presbyopes at the VDU workstation.

Accommodation, Ocular↗

Weight of edged spectacle lenses.

Uncut spectacle lenses of various powers and materials were edged to three different eye shapes and three box eye sizes. Their weights were measured. This demonstrated that the eye shape has very little effect on the weight of edged lenses and that there is very little difference in weight for neighbouring eye sizes. The density of the lens material is of major importance, but other characteristics also influence the edged lens weight.

Eyeglasses↗

Crystalline lens accommodation and anterior chamber depth.

Using paraxial equations, the change in dioptric power of the crystalline lens required to image objects at given distances from the eye, on the retina, is calculated. This shows that the depth of the anterior chamber affects crystalline lens accommodation more than other variables. The relationship between anterior chamber depth and presbyopia, and a possible geographical aspect, are discussed.

Accommodation, Ocular↗

Anthropometry for children's spectacle frames.

Facial measurements of 154 Caucasian children aged 5-14 were taken, to provide statistical information for spectacle frame manufacturers. The main differences compared with adult measurements were in the following dimensions: temple width, head width, bridge height, projection, splay angle and front to bend. The range of the 'distance between rims' measurement of adults, was similar to that of children. A number of differences between this group and a small group of Afro-Caribbean children was encountered.

Adolescent↗

The effect of prismatic spectacle and contact lens corrections on ocular rotation.

The effect of prismatic spectacle corrections on ocular rotation for different object distances is determined and evaluated. The same principles are applied for a correction fitted on the eye, that is, a contact lens correction. The latter must be considered as a thick lens system. The effects of different types of prismatic contact lenses on ocular rotation are considered. Assuming the contact lens to remain stationary and the eye behind the lens to rotate, it is shown that the theoretical effect on ocular rotation of prismatic contact lenses is practically equal to their prismatic effect in air. The effect for high-powered contact lenses is discussed.

Contact Lenses↗