PubMed Health⌕ Search

Biomedical subjects

H Olschewski

Publications and source records attributed to H Olschewski.

At least 37 records · Page 2Linked to original sources

Atrial natriuretic peptide in severe primary and nonprimary pulmonary hypertension: response to iloprost inhalation.

OBJECTIVES: The goal of this study was to assess atrial natriuretic peptide (ANP) levels during inhalation of iloprost in severe primary (PPH) and nonprimary pulmonary hypertension (NPPH). BACKGROUND: The ANP system is activated in pulmonary hypertension and may help protect from right ventricular (RV) decompensation. It is unknown if ANP regulation is the same in severe PPH and NPPH and if the dynamic regulation is intact in a highly activated ANP system. METHODS: In 11 patients with PPH and seven patients with NPPH, right heart catheter investigations were performed. Pulmonary and systemic artery ANP and cyclic guanosine monophosphate (cGMP) levels as well as hemodynamics were measured before and after iloprost inhalation. RESULTS: The baseline hemodynamics of patients with PPH and patients with NPPH were comparable (mean pulmonary artery pressure [mPAP]: 61 +/- 5 mm Hg vs. 52 +/- 5 mm Hg, pulmonary vascular resistance [PVR]: 1,504 +/- 153 dyne.s.cm(-5) vs. 1,219 +/- 270 dyne.s.cm(-5). Atrial natriuretic peptide and cGMP levels were increased about tenfold and fivefold compared with controls in both PPH and NPPH. Iloprost inhalation significantly decreased mPAP (-9.1 +/- 2.5 mm Hg vs. -7.9 +/- 1.5 mm Hg), PVR (-453 +/- 103 dyne.s.cm(-5) vs. -381 +/- 114 dyne.s.cm(-5)), ANP (-99 +/- 63 pg/ml vs. -108 +/- 47 pg/ml) and cGMP (-4.6 +/- 0.9 nM vs. -4.2 +/- 1.6 nM). Baseline ANP including all patients significantly correlated with PVR, right atrial pressure, cardiac index, RV ejection fraction, mixed venous oxygen saturation and cGMP. CONCLUSIONS: The ANP system is highly activated in patients with severe PPH and NPPH. Atrial natriuretic peptide levels are significantly correlated with parameters of RV function and pre- and afterload. Iloprost inhalation causes a rapid decrease in ANP and cGMP in parallel with pulmonary vasodilation and hemodynamic improvement.

Administration, Inhalation↗

Cellular pathophysiology and therapy of pulmonary hypertension.

The identification of several mutations of the bone morphogenetic protein receptor 2 (BMPR2) gene, a member of the transforming growth factor beta receptor family, gives hope for new insights into the pathophysiology of pulmonary hypertension. Genetic predisposition might dictate the responses of pulmonary artery fibroblasts, smooth muscle cells, and endothelial cells, as well as platelets and leukocytes, or their specific interactions with different extrinsic factors. These cells possess distinct subtypes and interact with each other. Pulmonary hypertension is associated with vasoconstriction, remodeling, and in situ thrombosis of the pulmonary arteries, but the initial events and their relationship to the genetic background are presently unknown. Current therapeutic approaches are based on our knowledge of the physiologic regulation of pulmonary artery tone, pathophysiologic changes, and our clinical experience with different treatment strategies. Beyond diuretics and anticoagulants, prostaglandins are generally accepted therapeutic agents for primary pulmonary hypertension and related diseases, whereas high-dose calcium-channel blockers are reserved for a small subset of patients, those who respond favorably to vasodilators in an acute test. Long-term intravenous prostacyclin infusion has become the most important specific therapy for primary pulmonary hypertension and associated diseases. However, this therapy is hampered by catheter complications and systemic side effects. Alternative application routes of prostacyclin or its stable analogs may avoid these problems. Inhaled application of the prostacyclin analog iloprost results in predominant pulmonary vasodilation with few systemic side effects and may possess clinical efficacy similar to that of intravenous prostacyclin. Inhaled nitric oxide is widely accepted as a screening agent for active responders to vasodilators and has a similar hemodynamic profile as inhaled iloprost, although the percentage of responders is considerably lower. However, there are unsolved toxicologic questions and practical difficulties concerning the safe long-term application of nitric oxide. Combining inhaled vasodilators with phosphodiesterase inhibitors may prolong the duration of the effects and improve the convenience of inhaled therapy for pulmonary hypertension. Therapeutic approaches in the future may aim at the transforming growth factor beta pathway and at the identification of early stages of the disease to prevent further disease progression.

Animals↗

Basic electrical properties of in situ endothelial cells of small pulmonary arteries during postnatal development.

Small pulmonary arteries are the major determinants of pulmonary artery pressure and vascular resistance. Their endothelium modulates pulmonary resistance, remodeling, and blood fluidity. We developed a method that provides access to the luminal surface of small pulmonary arteries of rat and allows the patch-clamp study of electrical properties of in situ endothelium. At birth, the membrane was predominantly permeable for K(+), showing a resting potential of -70 mV. This conductance was not voltage-dependent and was insensitive to standard blockers of K(+) channels such as tetraethylammonium, charybdotoxin, and 4-aminopyridine. The first 22 d of development were accompanied by an additional expression of a Cl(-) conductance, increasing membrane potential to -45 mV. Acidosis reduced K(+) conductance and depolarized the membrane, whereas alkalosis resulted in hyperpolarization. Two-electrode recordings revealed tight electrical coupling (83%) between neighboring cells in the circumferential direction of the artery. The electrotonic length constant for endothelium was 13.3 microm, indicating that most cells in one cross section of a small artery are well coupled. Thus, the resting membrane conductances in small pulmonary artery endothelial cells change with postnatal development and are modulated by pH.

Age Factors↗

Ultrasonic versus jet nebulization of iloprost in severe pulmonary hypertension.

Inhalation of iloprost, a stable prostacyclin analogue, is a promising perspective in the treatment of pulmonary hypertension. In initial clinical studies, a conventional jet nebulizer system was successfully used to decrease pulmonary vascular resistance and pressure, requiring however, up to twelve inhalations of 12-15 min per day. The aim of this study was to investigate if the application of an equal dose of iloprost at a drastically reduced duration of inhalation with the use of a more efficient ultrasonic nebulizer, leads to comparable haemodynamic effects, without escalation of side effects. The physical features of the jet nebulizer system (Ilo-Neb) and the ultrasonic nebulizer (Multisonic Compact) were characterized by laser diffractometry and a Tc99m-tracer technique. Mass median aerodynamic diameters were 3.2 microm for the jet and 3.9 microm for the ultrasonic nebulizer. Total output (mean+/-SD) was 60+/-7 microL.min(-1) (jet) and 163+/-15 microL.min(-1)(ultrasonic), and efficiency of the devices was 39+/-3% (jet) and 86+/-5% (ultrasonic). Based on these data, a total inhalative dose of 2.8 microg iloprost was delivered by jet nebulization within 12 min and by ultrasonic nebulization within 4 min, in 18 patients with severe primary and secondary pulmonary hypertension (New York Heart Association class III and IV), in a randomized crossover design. Haemodynamics were assessed by right heart catheterization. Inhalation with the ultrasonic device and jet nebulizer, reduced mean+/-SEM pulmonary artery pressure from 54.3+/-2.1 to 47.1+/-2.0 and from 53.5+/-2.2 to 47.0+/-2.2 mmHg, respectively, and mean+/-SEM pulmonary vascular resistance from 1,073+/-109 to 804+/-87 and from 1,069+/-125 to 810+/-83 dyn.s.cm(-5), respectively. Both modes of aerosolization were well tolerated. In conclusion, due to the markedly higher efficiency and output of the ultrasonic device, wastage of drug is largely avoided and the duration of inhalation can be shortened to one-third, with comparable haemodynamic effects and without enforcing side effects.

Administration, Inhalation↗

Abnormal pulmonary artery pressure response in asymptomatic carriers of primary pulmonary hypertension gene.

BACKGROUND: Familial primary pulmonary hypertension (PPH) is an autosomal-dominant inherited disease with incomplete penetrance and poor prognosis. This study was performed to examine whether asymptomatic carriers of a mutated PPH gene can be identified at an early stage by their pulmonary artery systolic pressure (PASP) response to exercise. METHODS AND RESULTS: Stress Doppler echocardiography during supine bicycle exercise and genetic linkage analysis were performed on 52 members of 2 families with PPH. In 4 PPH patients, the mean PASP was increased at rest (73+/-16 mm Hg). Fourteen additional family members with normal PASP at rest revealed an abnormal PASP response to exercise (from 23+/-4 to 56+/-11 mm Hg) without secondary cause (abnormal response [AR] group). Twenty-seven other members (NR group) revealed a normal PASP response (maximal pressure <40 mm Hg) to exercise (from 24+/-4 to 37+/-3 mm Hg, P<0. 0001). All 14 AR but only 2 NR members shared the risk haplotype with the PPH patients. The molecular genetic analysis supported linkage to chromosome 2q31-32 with a logarithm of the odds score of 4.4 when the 4 patients and the 14 AR members were classified as affected. CONCLUSIONS: We conclude that the pathological rise of PASP in asymptomatic family members is linked to chromosome 2q31-32 and is probably an early sign of PPH. Therefore, stress Doppler echocardiography may be a useful tool to identify persons at risk for PPH even before pulmonary artery pressures at rest are elevated.

Adolescent↗

Screen-printed enzyme sensors for l-lysine determination.

Sensors for the determination of L-lysine in samples of fermentation broth have been developed. Low-cost screen-printed sensors comprising a platinum working electrode, an Ag/AgCl pseudo reference and a carbon counter electrode were used as transducers for the enzyme sensors. L-lysine-(alpha)-oxidase from Trichoderma viride has been immobilized by entrapment into a polyurethane hydrogel. Sensors were characterized for L-lysine with respect to pH value, linear range, reproducibility, repeatability, storage and working stability. The sensitivities to other amino acids were also determined. A batch system with two working electrodes, one with immobilized enzyme and one without was adapted for the determination of L-lysine by differential measurements. Good agreement was found between L-lysine concentrations measured by the enzyme sensors and by a conventional amino acid analyzer.

Journal Article↗

Inhaled iloprost to treat severe pulmonary hypertension. An uncontrolled trial. German PPH Study Group.

BACKGROUND: Inhaled aerosolized iloprost, a stable prostacyclin analogue, has been considered a selective pulmonary vasodilator in the management of pulmonary hypertension. OBJECTIVE: To assess the efficacy of inhaled iloprost in the treatment of life-threatening pulmonary hypertension. DESIGN: Open, uncontrolled, multicenter study. SETTING: Intensive care units and pulmonary hypertension clinics at six university hospitals in Germany. PATIENTS: 19 patients who had progressive right-heart failure despite receiving maximum conventional therapy (12 with primary pulmonary hypertension, 3 with pulmonary hypertension related to collagen vascular disease without lung fibrosis, and 4 with secondary pulmonary hypertension). INTERVENTION: Inhaled iloprost, 6 to 12 times daily (50 to 200 microg/d). MEASUREMENTS: Right-heart catheterization and distance walked in 6 minutes at baseline and after 3 months of therapy. RESULTS: During the first 3 months of therapy, New York Heart Association functional class improved in 8 patients and was unchanged in 7 patients. Four patients died, 3 of right-heart failure and 1 of sepsis. The acute hemodynamic response to inhaled iloprost was predominant pulmonary vasodilatation with little systemic effect at baseline and at 3 months (data available for 12 patients). Hemodynamic variables were improved at 3 months, and the distance walked in 6 minutes improved by 148 m (95% CI, 4.5 to 282 m; P = 0.048). Of the 15 patients who continued to use inhaled iloprost, 8 stopped: Four had lung transplantation, 1 switched to intravenous prostacyclin therapy, and 3 died. Seven patients are still receiving inhaled iloprost (mean +/-SD) duration of therapy, 536 +/- 309 days; mean dosage, 164 +/- 38 microg/d). CONCLUSIONS: Inhaled iloprost may offer a new therapeutic option for improvement of hemodynamics and physical function in patients with life-threatening pulmonary hypertension and progressive right-heart failure that is refractory to conventional therapy.

Administration, Inhalation↗

[Inhalative strategies for improvement of pulmonary hemodynamics and gas exchange in sepsis and severe pulmonary hypertension].

Chronic pulmonary hypertension and septic lung failure display different clinical features resulting in severe disturbances in the pulmonary circulation. In these diseases, the pulmonary bloodflow is impaired by a pathologic constriction of blood vessels that may lead to right ventricular overloading as well as serious worsening of gas exchange mainly caused by ventilation/perfusion mismatch. Various mechanisms deteriorating the vascular function may induce both an irreversible and a reversible contraction of pulmonary vessels, respectively. Two pharmacological approaches exist to reduce the vascular resistance: Reduction of the increased vascular tone by relaxation of vascular smooth muscle cells (effect of vasodilators). Inhibition of thrombus-mediated obliteration of the lung perfusion by use of anticoagulant and fibrinolytic drugs. Prevention of the structural reorganization of pulmonary vessels (vascular remodeling) by use of vasodilators with anti-inflammatory and anti-proliferative potency such as prostanoids. The systemic (intravenous or oral) application of vasodilative agents in sepsis and chronic pulmonary hypertension has, however, important side effects: Antagonism of the hypoxic pulmonary vasoconstriction aggravates the ventilation/perfusion mismatch (decrease in arterial oxygenation). Side effects of these vasodilators (systemic hypotension). The inhalative route of application is superior because of the pulmonary enrichment of the applied agent (pulmonary selectivity). Furthermore, a preferential deposition in the well-ventilated areas of the lung is achieved (intrapulmonary selectivity). Thus, the decrease in pulmonary-vascular resistance is paralleled by both optimized ventilation-perfusion matching and subsequently improved gas exchange. First clinical studies with inhaled nitric oxide and aerosolized prostacyclin have been performed in intubated and mechanically ventilated patients with septic lung failure. At present, the use of the long-acting prostacyclin analogue ilomedin for ambulant treatment of patients with chronic pulmonary hypertension is under investigation.

Acute Disease↗

A comparison of the acute hemodynamic effects of inhaled nitric oxide and aerosolized iloprost in primary pulmonary hypertension. German PPH study group.

OBJECTIVE: We sought to compare the acute hemodynamic effects of inhaled nitric oxide (NO) and aerosolized iloprost in primary pulmonary hypertension (PPH). BACKGROUND: Inhalation of the stable prostacyclin analogue iloprost has recently been described as a novel therapeutic strategy for PPH and may offer an alternative to continuous intravenous infusion of prostacyclin or inhalation of NO. METHODS: During right heart catheterization, 35 patients with PPH sequentially inhaled 40 ppm of NO and 14 to 17 microg of iloprost, and the effects on hemodynamics and blood gases were monitored. RESULTS: Both NO and iloprost caused significant increases in cardiac output, mixed-venous oxygen saturation and stroke volume as well as significant decreases in pulmonary artery pressure and pulmonary vascular resistance, whereas only inhaled iloprost significantly increased the arterial PO2 (p = 0.01). Compared with inhaled NO, aerosolized iloprost was more effective in reducing pulmonary artery pressure (-8.3 +/- 7.5 mm Hg vs. -4.3 +/- 8.8 mm Hg; p = 0.0001) and the pulmonary vascular resistance (-447 +/- 340 dynes x s x cm(-5) vs. -183 +/- 305 dyne x s x cm(-5); p < 0.0001). Furthermore, aerosolized iloprost caused a significantly greater increase of the cardiac output compared with NO (+0.7 +/- 0.6 liter/min vs. +0.3 +/- 0.4 liter/min; p = 0.0002) and had a more pronounced effect on the mixed-venous oxygen saturation (p = 0.003). CONCLUSIONS: During acute drug testing, aerosolized iloprost was more potent than inhaled NO as a pulmonary vasodilator in PPH at the doses used in this study.

Administration, Inhalation↗

[Inhaled prostacyclin and iloprost in severe pulmonary hypertension secondary to pulmonary fibrosis].

Pulmonary hypertension is a life-threatening complication of lung fibrosis. Vasodilator therapy is difficult owing to systemic side effects and pulmonary ventilation-perfusion mismatch. We compared the effects of intravenous prostacyclin and inhaled NO and aerosolized prostacyclin in randomized order and, in addition, tested for effects of oxygen and systemic calcium antagonists (CAAs) in eight patients with lung fibrosis and pulmonary hypertension. Aerosolized prostaglandin (PG)I2 caused preferential pulmonary vasodilatation with a decrease in mean pulmonary arterial pressure from 44.1 +/- 4.2 to 31.6 +/- 3.1 mmHg, and pulmonary vascular resistance (RL) from 810 +/- 226 to 386 +/- 69 dyn.s.cm-5 (p < 0.005, respectively). Systemic arterial pressure, arterial oxygen saturation, and pulmonary right-to-left-shunt flow, measured by multiple inert gas analysis, were not significantly changed. Inhaled NO similarly resulted in selective pulmonary vasodilatation, with RL decreasing from 726 +/- 217 to 458 +/- 81 dyn.s.cm-5. In contrast, both intravenous PGI2 and CAAs were not pulmonary selective, resulting in a significant drop in arterial pressure. In addition PGI2 infusion caused a marked increase in shunt flow. Long-term therapy with aerosolized iloprost (long-acting PGI2 analog) resulted in unequivocal clinical improvement from a state of immobilization and severe resting dyspnea in a patient with decompensated right heart failure. We concluded that, in pulmonary hypertension secondary to lung fibrosis, aerosolization of PGI2 or iloprost causes marked pulmonary vasodilatation with maintenance of gas exchange and systemic arterial pressure. Long-term therapy with inhaled iloprost may be life saving in decompensated right heart failure from pulmonary hypertension secondary to lung fibrosis.

Administration, Inhalation↗

[Prevalence of stroke and transitory ischemic attacks in obstructive sleep apnea: a retrospective analyis so f 187 consecutive patients].

BACKGROUND: Obstructive sleep apnea (OSA) is presumed to be significantly associated with cerebrovascular disease; however, there are no consistent epidemiological data providing proof of such a link. Hence, the aim of the present study was to determine the prevalence of stroke and transient ischemic attack (TIA) in patients with OSA. PATIENTS AND METHODS: 187 consecutive patients with a polysomnographically verified diagnosis of OSA who had been admitted to our sleep laboratory during 1/98-3/00 were retrospectively analysed. RESULTS: The prevalence of stroke and TIA was 7%. This rate was lower if compared with those for coronary artery disease and arterial hypertension in the same study cohort (14% and 53% respectively). The 13 OSA patients with stroke were elderly overweight men (age: 64 +/- 1.7 years, BMI: 31.4 +/- 1.1 kg/m2). They had quite severe OSA (AHI: 43 +/- 5/h) and almost all of them suffered from arterial hypertension. In all cases, the insult was caused by cerebral or brain stem ischemia. None of the patients presented with persistent neurological deficits. The mean latency period between the occurrence of stroke or TIA and the diagnosis of OSA was 41.9 +/- 11.3 months. CONCLUSION: In summary, the prevalence of stroke or TIA in our series of 187 consecutive OSA patients was 7%. Further prospective studies controlling for confounding factors such as age, body weight and arterial hypertension are needed to clarify the risk potential of OSA for the development of cerebrovascular disorders.

Aged↗

Decreased plasma levels of nitric oxide derivatives in obstructive sleep apnoea: response to CPAP therapy.

BACKGROUND: Reduced endothelium dependent vasodilation has been reported in patients with obstructive sleep apnoea (OSA) but direct measurements of the most potent naturally occurring vasodilator, nitric oxide (NO) or its derivatives (nitrate and nitrite, NO(x)), have not yet been performed in these patients. METHODS: In 21 patients with OSA of mean (SE) age 54 (2) years, body mass index (BMI) 30.9 (1.1) kg/m(2), and apnoea-hypopnoea index (AHI) 37 (4)/h, NO(x) levels were measured in peripheral venous blood samples by chemiluminescence. Blood samples were obtained before and after two nights of continuous positive airway pressure (CPAP) and after 5.5 (1.5) months of follow up. Thirteen age matched, healthy volunteers and 18 patients without OSA but with a similar spectrum of comorbidity served as controls (control groups 1 and 2). RESULTS: Before CPAP NO(x) levels were 21.7 (1.5) microM in patients with OSA compared with 42.6 (2.2) microM and 36.7 (1.7) microM in control groups 1 and 2, respectively (p<0.01 for each comparison). NO(x) concentrations increased to 32.1 (2.7) microM after two nights of CPAP and remained constant at 32.9 (2.3) microM at follow up (p<0.01 compared with levels before CPAP). CONCLUSIONS: Plasma NO(x) levels are reduced in OSA and can be increased by short and long term CPAP therapy. Although the precise mechanism underlying this observation remains to be clarified, it may have important implications for the development of cardiovascular disease in patients with OSA and for the life saving effect of CPAP.

Case-Control Studies↗