Monolithic microfabricated valves and pumps by multilayer soft lithography.

Soft lithography is an alternative to silicon-based micromachining that uses replica molding of nontraditional elastomeric materials to fabricate stamps and microfluidic channels. We describe here an extension to the soft lithography paradigm, multilayer soft lithography, with which devices consisting of multiple layers may be fabricated from soft materials. We used this technique to build active microfluidic systems containing on-off valves, switching valves, and pumps entirely out of elastomer. The softness of these materials allows the device areas to be reduced by more than two orders of magnitude compared with silicon-based devices. The other advantages of soft lithography, such as rapid prototyping, ease of fabrication, and biocompatibility, are retained.

Adhesiveness↗

A microfabricated device for sizing and sorting DNA molecules.

We have demonstrated a microfabricated single-molecule DNA sizing device. This device does not depend on mobility to measure molecule size, is 100 times faster than pulsed-field gel electrophoresis, and has a resolution that improves with increasing DNA length. It also requires a million times less sample than pulsed-field gel electrophoresis and has comparable resolution for large molecules. Here we describe the fabrication and use of the single-molecule DNA sizing device for sizing and sorting DNA restriction digests and ladders spanning 2-200 kbp.

Bacteriophage lambda↗

A microcomputer-based whole-body counter for personnel routine monitoring.

The paper describes a cost-effective NaI(Tl) whole-body counter developed for routine examinations of worker intakes at an isotope production facility. Signal processing, data analysis and system operation are microcomputer-controlled for minimum human interactions. The pulse height analyzer is developed as an microcomputer add-on card for easy manipulation. The scheme for radionuclide analysis is aimed for fast running according to a knowledge base established from background samples and phantom experiments in conjunction with a multivariate regression analysis. Long-term stability and calibration with standards and in vivo measurements are reported.

Humans↗

Evaluation of high density DRAMs as a nuclear radiation detector.

The research is based on the nuclear radiation induced soft error phenomenon associated with dynamic random access memory devices (DRAMs). Samples of 256 kbit and 1 Mbit decapped DRAMs from several manufactures were exposed to standard alpha sources and showed a linear response with an intrinsic detection efficiency approaching 10%. Sensitivity studies were performed to evaluate the effects of DRAM operating voltage, refresh frequency and the data pattern stored prior to irradiation. The associated mechanism of soft error phenomenon is discussed. Samples were also exposed to gamma rays up to 10(5) rad to examine the total dose effect. The annealing phenomenon after gamma exposure is also presented.

Alpha Particles↗