H Parsaei

Publications and source records attributed to H Parsaei.

3 recordsLinked to original sources

Dynamic and omni wedge implementation on an Elekta SL linac.

The concommitant use of a multileaf collimator (MLC) and a wedge can result in conflicts in the optimal collimator angle if both MLC and wedge are fixed relative to one another. This is particularly true of linacs in which a single wedge orientation is provided. In this paper, a solution is provided that makes use of two orthogonal universal wedges (omni wedge). Although this technique can be applied regardless of the means by which the wedged fields are implemented, the measurements reported in this paper were performed using a fixed, internal mechanical wedge coupled with a dynamic wedge, formed by the motion of one of the backup jaws. An implementation of a dynamic wedge for the Elekta SL series of linear accelerators is presented. Results of measurements of the dosimetric characteristics of both the particular implementation of the dynamic wedge and of the omni field are presented. For the dynamic wedge, measurements were made of the wedge factor and dose profile as a function of field size and depth. In addition, the effects of variables, such as dynamic delivery technique and direction of diaphragm motion, on the dynamic wedge profiles were studied and discussed. For the omni wedge, measurements were made of the degree to which the mathematical formalism for describing an omni wedge matches the measured isodose distributions. Comparisons between mechanical wedge dose distributions and the omni wedge were also made.

Dose-Response Relationship, Radiation↗

Lung compensator design using an electronic portal imaging device.

Using a liquid filled electronic portal imaging device (EPID) installed on a linear accelerator and a composite chest phantom, exit dose measurements were carried out to establish an empirical relationship between the pixel values of the imaging detector and the corresponding equivalent thickness of the overlying phantom material. Results for 6 and 10 MV photons show that the relationship depends on the so-called input/output characteristics of the imaging device for a particular photon energy. For a chest irradiation, an EPID image obtained under treatment geometry provides the pixel value information that is used to calculate the tissue deficit over the lung region. The compensators are made of lead whose thickness is calculated from the established empirical relationship to replace the tissue deficit over lungs. The effectiveness of the method is demonstrated with thermoluminescent dosimetry (TLD) for 6 and 10 MV beams. With compensators in place, the dose uniformity was found to be within +/- 5%.

Humans↗

The use of an electronic portal imaging system to measure portal dose and portal dose profiles.

The dosimetric characteristics of a scanning liquid-filled ionization chamber (SLIC) electronic portal imaging device have been investigated. To assess the system's response in relation to incident radiation beam intensity, a series of characteristic curves are obtained for various field sizes and nominal energies of 6 and 10 MV photons. The response of the imaging system is dependent on incident radiation intensity and can be described to within 1% accuracy on central axis using a square root function. Portal dose measurements with the SLIC at the plane of the detector, on central axis of the beam using homogeneous attenuating phantom materials show that the imaging system is capable of measuring the portal (transmission) dose to within 3% of the ionization chamber results for homogeneous material. For two-dimensional dosimetry applications, the system is calibrated with a 10 cm Perspex block used as beam flattening material on the detector cassette to correct for variations in individual ion chamber sensitivity and the effect of nonuniform beam profiles produced by the flattening filter. Open and wedged dose profiles measured with the SLIC agreed with ion chamber measured profiles to within 3.5% accuracy.

Biophysical Phenomena↗