PubMed Health⌕ Search

Biomedical subjects

H Ratiney

Publications and source records attributed to H Ratiney.

3 recordsLinked to original sources

Time-domain semi-parametric estimation based on a metabolite basis set.

A novel and fast time-domain quantitation algorithm--quantitation based on semi-parametric quantum estimation (QUEST)--invoking optimal prior knowledge is proposed and tested. This nonlinear least-squares algorithm fits a time-domain model function, made up from a basis set of quantum-mechanically simulated whole-metabolite signals, to low-SNR in vivo data. A basis set of in vitro measured signals can be used too. The simulated basis set was created with the software package NMR-SCOPE which can invoke various experimental protocols. Quantitation of 1H short echo-time signals is often hampered by a background signal originating mainly from macromolecules and lipids. Here, we propose and compare three novel semi-parametric approaches to handle such signals in terms of bias-variance trade-off. The performances of our methods are evaluated through extensive Monte-Carlo studies. Uncertainty caused by the background is accounted for in the Cramér-Rao lower bounds calculation. Valuable insight about quantitation precision is obtained from the correlation matrices. Quantitation with QUEST of 1H in vitro data, 1H in vivo short echo-time and 31P human brain signals at 1.5 T, as well as 1H spectroscopic imaging data of human brain at 1.5 T, is demonstrated.

Algorithms↗

Time-domain quantitation of 1H short echo-time signals: background accommodation.

Quantitation of 1H short echo-time signals is often hampered by a background signal originating mainly from macromolecules and lipids. While the model function of the metabolite signal is known, that of the macromolecules is only partially known. We present time-domain semi-parametric estimation approaches based on the QUEST quantitation algorithm (QUantitation based on QUantum ESTimation) and encompassing Cramér-Rao bounds that handle the influence of 'nuisance' parameters related to the background. Three novel methods for background accommodation are presented. They are based on the fast decay of the background signal in the time domain. After automatic estimation, the background signal can be automatically (1) subtracted from the raw data, (2) included in the basis set as multiple components, or (3) included in the basis set as a single entity. The performances of these methods combined with QUEST are evaluated through extensive Monte Carlo studies. They are compared in terms of bias-variance trade-off. Because error bars on the amplitudes are of paramount importance for diagnostic reliability, Cramér-Rao bounds accounting for the uncertainty caused by the background are proposed. Quantitation with QUEST of in vivo short echo-time (1)H human brain with estimation of the background is demonstrated.

Brain↗

Dynamic magnetic resonance imaging paragraph sign with radial scanning: a post-acquisition paragraph sign keyhole approach.

A method - PA-keyhole - for 2D/3D dynamic magnetic resonance imaging with radial scanning is proposed. PA-keyhole exploits the inherent strong oversampling in the center of k-space, which contains crucial temporal information regarding contrast evolution. The method is based on: (1). a rearrangement of the temporal order of 2D/3D isotropic distributions of trajectories during the scan into subdistributions according to the desired time resolution, (2). a new post-acquisition keyhole approach based on the replacement of the central disk/sphere in k-space using data solely from a subdistribution, and (3). reconstruction of 2D/3D dynamic (time-resolved) images using 2D/3D-gridding with Pipe's approach to the sampling density compensation and 2D/3D-IFFT. The scan time is not increased with respect to a conventional 2D/3D radial scan of the same spatial resolution; in addition, one benefits from the dynamic information. The abilities of PA-keyhole and the sliding window techniques to restore simulated dynamic contrast changes are compared. Results are shown both for 2D and 3D dynamic imaging using experimental data. An application to in-vivo ventilation of rat lungs using hyperpolarized helium is demonstrated.

Algorithms↗