PubMed Health⌕ Search

Biomedical subjects

H Reichenspurner

Publications and source records attributed to H Reichenspurner.

At least 37 records · Page 2Linked to original sources

Effect of cardiopulmonary bypass on myocardial function, damage and inflammation after cardiac surgery in newborns and children.

UNLABELLED: Postoperative measurement of cardiac troponin I, creatine kinase and procalcitonin reflects myocardial damage and systemic inflammatory response after cardiac surgery with cardiopulmonary bypass in children. Pulse-contour cardiac output technique is a less invasive tool for determining postoperative cardiac function. OBJECTIVE: The aim of our study was to investigate myocardial lesions and systemic inflammatory response after cardiac surgery with cardiopulmonary bypass in children suffering from congenital heart defects. METHODS: The elevation of cardiac troponin I (cTnI), creatine kinase (CK) and procalcitonin (PCT) was evaluated in relationship to duration of aortic cross-clamping, incisional trauma and cardiac bypass temperature in 37 paediatric patients. To assess postoperative cardiac function, the cardiac index was measured in 7 children using the PiCCO (pulse contour cardiac output) technique. RESULTS: CTnI and PCT both peaked on the day of surgery and slowly decreased postoperatively in case of an uncomplicated course. The median values of both parameters differed significantly from the day of surgery until the fourth postoperative day in children with an aortic cross-clamping time (CCT) longer than 80 minutes or after ventriculotomy in comparison to patients with shorter clamping times or atriotomy only. CK values showed similar results, but were less significant than cTnI. A relationship between cTnI, CK or PCT and the body temperature during cardiopulmonary bypass was not found. The cardiac indices (CI) measured by the PiCCO technique in the first 48 hours after surgery showed normal values. CONCLUSION: In summary, perioperative measurement of cTnI, CK and PCT reflects myocardial damage and systemic inflammatory response and allows an improved peri- and postoperative management. PiCCO technique is an excellent, less invasive tool to determine postoperative cardiac function.

Biomarkers↗

Pseudoaneurysm complicating homograft aortic valve replacement--two different--courses and strategies.

The courses of two patients with pseudoaneurysm formation following aortic valve replacement using homografts are reported. Both patients had aortic valve replacement due to acute infective endocarditis with paravalvular abscess formation. The first case had an uneventful postoperative course; but on routine echocardiography, a pseudoaneurysm located at the left coronary commissure was found at one year follow-up. As the pseudoaneurysm was completely asymptomatic, the patient was followed up carefully at six months intervals. The second patient also had pseudoaneurysm formation postoperatively, but he presented one year after surgery with fever and elevated leucocyte count. He had surgical revision of the pseudoaneurysm because no other reason for an infection could be found. Four months later he presented again with infection signs and pseudoaneurysm formation. This time, the homograft was completely excised and another homograft was implanted. One year after the final operation, he is now free from re-infection. The two presented courses show that pseudoaneurysms complicating aortic valve replacement should be managed according to attendant circumstances and symptoms.

Adult↗

A multicenter initial clinical experience with right heart support and beating heart coronary surgery.

BACKGROUND: During coronary surgery without CPB, exposure of posterior vessel via sternotomy can cause deterioration of cardiac hemodynamics requiring inotrope drugs support. Recent animal experiments demonstrate hemodynamic benefit of right heart support (RHS) with the AMED system. The purpose of this study was to evaluate the hemodynamic effects during cardiac manipulation to expose the posterior coronary arteries, and determine the effect of RHS in restoring hemodynamics, increasing anastomotic exposure and reducing inotropic requirements. MATERIAL AND METHODS: From July 28 to December 29, 32 patients (25 men/7 women), mean age of 63.4 (+/- 6.2 years, ages: 49-78) received coronary revascularization with the A-Med RHS device. They were divided into two groups of 16 patients, A and B. Group A patients had at least one circumflex branch bypassed. The anterior wall was systematically bypassed off-pump without RHS. The right coronary artery (RCA) and the obtuse coronary artery (OM) were completed utilizing RHS. In group B patients, all vessels including anterior vessels were bypassed with the RHS. Mean arterial pressure (MAP), mean pulmonary arterial pressure (PAP), cardiac output (CO) and the average pump flow (APF) were recorded during the OM and RCA bypass for group A, and for group B LAD data was also recorded. RESULTS: Elective beating heart coronary artery bypass graft (CABG) was successfully accomplished in 32 patients with RHS. Data measurements recorded in Group A showed the improved hemodynamic recovery for OM and RCA bypass with RHS. The MAP increased from 44 to 68 mmHg (OM) and from 63 to 81 mmHg (RCA); the CO from 2.1 to 4.4 L/min (OM) and from 3.3 to 4.7 L/min (RCA). In group B, the data recorded showed the stability of the MAP in all vessels bypassed (LAD, OM and RCA). No device-related patient incidents occurred. All 32 patients were discharged to their homes. CONCLUSIONS: The AMED system, as RHS support, facilitated coronary bypass without CPB to posterior vessels, restoring hemodynamics, providing better exposure to anastomotic sites and apparently reducing inotropes need. Prospective randomize trials are necessary to confirm this initial experience.

Aged↗

Elevated levels of interleukin-8 and transforming growth factor-beta in bronchoalveolar lavage fluid from patients with bronchiolitis obliterans syndrome: proinflammatory role of bronchial epithelial cells. Munich Lung Transplant Group.

BACKGROUND: Obliterative bronchiolitis (OB), the most important long-term complication after lung transplantation, is thought to be a manifestation of chronic rejection within the airways, with the hallmarks inflammation and fibroproliferation. METHODS: To characterize the inflammatory process in the context of OB we quantified tumor necrosis factor-alpha, interleukin (IL)-8, IL-10, and transforming growth factor (TGF)-beta on the protein and mRNA level in bronchoalveolar lavage fluid samples obtained from patients with bronchiolitis obliterans syndrome (BOS) and without BOS. In addition, bronchial cells sampled by bronchial brushing were analyzed for mRNA expression. RESULTS: In respiratory epithelial lining fluid (ELF) from BOS patients the protein levels of IL-8 (52.4+/-22.2 vs. 4.4+/-0.9 pg/ml ELF, P<0.005) and TGF-beta (5.6+/-1.9 vs. 0.9+/-0.2 ng/ml ELF, P<0.005) were significantly elevated. In addition, bronchoalveolar lavage fluid cells of BOS patients showed increased expression of TGF-beta (1.13+/-0.44 vs. 0.45+/-0.16, optical density [O.D.]/O.D. glyceraldehyde-3-phosphate dehydrogenase [GAPDH], P=0.11) and IL-8 (0.25+/-0.13 vs. 0.09+/-0.03 O.D/O.D. GAPDH, P=0.53) without the differences reaching statistical significance. In contrast, IL-8 mRNA expression of bronchial cells was significantly higher in the BOS group (0.85+/-0.40 vs. 0.22+/-0.10 O.D./O.D. GAPDH, P<0.05). CONCLUSIONS: We assume that IL-8 and TGF-beta may act as key mediators for airway inflammation and fibroproliferation in the pathogenesis of OB, with bronchial epithelial cells serving as a relevant source of IL-8.

Adult↗

Reduced myocardial cellular damage and lipid peroxidation in off-pump versus conventional coronary artery bypass grafting.

BACKGROUND: The development of new surgical devices and techniques allows off pump coronary artery bypass grafting (OPCAB) without the use of CPB and cardioplegia. This study tested whether OPCAB reduces myocardial cell damage, lipid peroxidation and systemic endothelin release when compared to conventional coronary artery bypass grafting. METHODS: Twenty-six patients were assigned to either the OPCAB procedure using a suction device and regular sternotomy (n = 13) or were treated conventionally using extracorporeal circulation, blood cardioplegia and hypothermic arrest (29-31 degrees C; n = 13). Troponin I and creatine kinase - MB were determined for cardiac specific cell damage. Myocardial and systemic malondialdhyde levels were measured to account for oxyradical mediated lipid peroxidation. Systemic big-endothelin levels were determined as a marker for endothelial cell activation. RESULTS: A significant reduction of the cardiac specific cell damage was observed in the OPCAB group vs. the CABG group over time in the absence of acute myocardial ischemia or infarction. In addition, systemic and myocardial lipid peroxidation as measured by the malondialdehyde (MDA) levels were lower in the OPCAB group when compared to CABG. Finally, plasma levels of big-Endothelin (big-ET) significantly rose in the CABG but not in the OPCAB group. CONCLUSIONS: The data of the present study indicate that OPCAB revascularization without the use of CPB and cardioplegic arrest reduces myocardial cell damage and lipid peroxidation. It is also associated with a reduced activation of the potent vasoconstrictor peptide endothelin. All of this may contribute to improved myocardial function and faster postoperative recovery from surgical revascularization procedures, particularly in critically ill patients.

Aged↗

IG-therasorb immunoapheresis in orthotopic xenotransplantation of baboons with landrace pig hearts.

BACKGROUND: The major problem of xenotransplantation is, that hyperacute xenograft rejection (HXR) causes graft failure within minutes or a few hours because of natural antibodies and activation of the complement system. As a preclinical model we transplanted pig hearts orthotopically into baboons. To prevent HXR after orthotopic xenotransplantation (oXHTx), the immunoglobulins (Ig) and natural antibodies were adsorbed to reusable Ig-Therasorb immunoadsorption (IA) columns. METHODS: We performed three oXHTx of landrace pig hearts into baboons (19+/-6.8 kg), using extracorporeal circulation (ECC) connected to the IA unit. After separating the recipient's blood into plasma and cellular fraction by a plasma filter, plasma flow was directed to the Ig-Therasorb column coated with polyclonal sheep-antibodies against human IgG, IgM, and IgA. Intraoperative treatment consisted of 4 cycles of IA. For a control, we transplanted one pig heart into a baboon (16.9 kg) without applying IA. Perioperatively, serum concentrations of Ig, anti-pig-antibodies, complement and cardiac enzymes were determined. Tissue samples of myocardium were collected at the end of the study for immunohistochemical examinations, light microscopic examination (LM) and electron microscopic examination (EM). For cardiac monitoring after oXHTx, we used ECG, echocardiography, and invasive measurement of cardiac output. To prevent a mismatch of donor and recipient heart size, the donor pig had a 30-40% lower body weight than the recipient baboon. RESULTS: Four cycles of IA removed >80% of IgG, IgM, and IgA from plasma. The graft of the control animal failed after 29 min. The first oXHTx with IA was intentionally terminated after 100 min, the second oXHTx after 11 hr and the third oXHTx after 21 hr. All xenografts showed no histological signs of HXR. After weaning off ECC, these donor hearts worked in sinus rhythm without electrocardiographic ST-segment elevation. An excellent cardiac output was measured by echocardiography and thermodilution (2 L/min). Serological parameters indicating cardiac damage were significantly lower after IA if compared with the control experiment. Macroscopically, the xenograft of the control animal showed massive hemorrhage in comparison with the almost inconspicuous grafts after IA. The myocardium of the IA group demonstrated fewer deposits of Ig and complement components compared with the control animal. CONCLUSION: Baboons do not hyperacutely reject a porcine xenograft after antibody depletion by the Ig-Therasorb column. In our experiment only 4 cycles of immunoapheresis effectively prevented HXR after oXHTx of baboons. The Ig-Therasorb column is a reusable device, which can be handled easily in combination with the ECC. IA must be tested in oXHTx longterm survival experiments, especially in combination with transgenic pig organs, which could be a reliable preclinical approach for future clinical xenotransplantation.

Animals↗

Influence of ischemic time on hyperacute xenograft rejection of pig hearts in a working heart perfusion model with human blood.

In xenotransplantation long ischemic time of grafts is supposed to have a marked influence on hyperacute rejection (HXR). We investigated the influence of different cold ischemic times on HXR of ex vivo "working pig hearts" perfused with human blood. Xenoreactive natural antibodies (XNAb) as a trigger of HXR were eliminated by Ig-Therasorb immunoadsorption (IA). Explanted Landrace pig hearts of group G1 and group G3 (with additional IA) underwent 4 h of cold ischemia prior to xenoperfusion. Control groups G2 and G4 (with IA) were kept ischemic for only 46.6 +/- 15.8 and 51.2 +/- 4.2 min, respectively. Ischemic time prolonged the perfusion time in our working heart model (G1: 356 +/- 46.1 min; G2: 125 +/- 31 min; P < 0.05). IA had no additional impact on perfusion time but was effective by itself. The heart weight increased fourfold more in G2 as compared to the other groups. IA without ischemia significantly improved cardiac output in G4 (G3: 198.8 +/- 15.4 mL/min; G4: 338.5 +/- 16.0 mL/min). Coronary flow in G2 was significantly lower than in G1 (G1: 157.9 +/- 9.15 mL/min; G2: 59.4 +/- 20.1 mL/min). Histological signs of HXR (light and electron microscopy) could be found in G2 in contrast to the other groups. Parameters of serological damage showed a minimum in G4 and the maximum in G2. In G1 XNAb were nearly equally eliminated immediately after the start of xenoperfusion as in IA groups G4 and G3. Four hours of ischemic time showed beneficial effects in preventing HXR, possibly caused by changes of the endothelial cell surface (for example, glycosylation or loss of alpha1-3Gal epitopes with a hapten effect).

Acute Disease↗

Prevention of hyperacute xenograft rejection in orthotopic xenotransplantation of pig hearts into baboons using immunoadsorption of antibodies and complement factors.

To prevent hyperacute xenograft rejection (HXR) caused by preformed natural antibodies (XNAb) after orthotopic heart xenotransplantation (oXHTx) of landrace pig hearts into baboons, we used immunoadsorption of immunoglobulins IgG, IgM and IgA and complement with the reusable Ig-Therasorb column. In addition to functional data, tissue was sampled for histological, immunohistochemical and electron microscopical analysis. We performed three oXHTx of landrace pig hearts to baboons using extracorporeal circulation (ECC) connected to the immunoadsorption unit. Intraoperative treatment consisted of four cycles of immunoabsorption (IA). One oXHTx of a baboon without IA served as a control. A mismatch of donor and recipient heart size was prevented by selecting a 30-40% lower body weight of donor pigs than recipients. Four cycles of IA removed more than 80% of IgG, IgM and IgA, 86% of antipig antibodies and 66% of complement factors C3 and C4 from plasma. The graft of the control animal failed after 29 min. Orthotopic xenotransplantation with IA was selectively terminated after 100 min, 11 h and 21 h, respectively without any histological signs of HXR in light and electron microscopy. After weaning off from ECC these donor xenografts showed sufficient function with normal ECG and excellent cardiac output in echocardiography and invasive measurement (1.93 +/- 0.035 l/min). The myocardium of the control xenograft demonstrated more deposits of Ig and complement components (C3, C4) than in the IA group. Baboons survive HXR after orthotopic pig heart xenotransplantation due to antibody depletion by reusable Ig-Therasorb column treatment. Long-term survival in an orthotopic baboon xenotransplantation model after IA, especially in combination with transgenic pig organs, could be a reliable preclinical trial for future clinical xenotransplantation programs.

Acute Disease↗

[Pseudoaneurysm after Bentall's procedure in acute aortic dissection type A: diagnosis using electron beam tomography].

Pseudoaneurysms are a rare complication following replacement of the ascending aorta or aorto-coronary bypass surgery. We report a case with replacement of the aorta ascendens, the aortic valve, and venous aorto-coronary bypass grafting, in whom a pseudoaneurysm developed at the site of one proximal bypass anastomosis. For the preoperative diagnosis, an ultrafast-CT (Electron Beam Tomography, EBT) was done, as neither the pseudoaneurysm, nor the venous graft could be visualized by selective coronary angiography.

Adult↗

Right heart circulatory support facilities coronary artery bypass without cardiopulmonary bypass.

BACKGROUND: Revascularization of the posterior wall often causes hemodynamic instability in beating heart coronary artery bypass (CAB). Our previous clinical studies have shown that tilting the heart primarily alters right-heart hemodynamics. The purpose of this study was to evaluate right-heart support in clinical cases. METHODS: Seventeen patients underwent beating heart CAB with right-heart support. The right-heart support system (A-Med Systems, West Sacramento, CA) consisted of a coaxial cannula placed through the right atrium and the tip of the cannula positioned in main pulmonary artery. Blood was removed from the right atrium and returned to the main pulmonary artery. RESULTS: Elective beating heart CAB was accomplished successfully in 17 patients with right-heart support. Anastomoses performed were left anterior descending coronary artery (11), diagonal (3), circumflex (5), obtuse marginal artery (11), and right coronary artery (10). Right-heart support between 1 and 3 L/min improved hemodynamics especially in the circumflex position. No device-related patient incidents occurred, nor were there incidents of infection or air embolism. All 17 patients were discharged to their homes. CONCLUSIONS: The right-heart support system was safe without complications. Exposure of the posterior wall was possible in all cases without hemodynamic compromise.

Aged↗

Three-dimensional video and robot-assisted port-access mitral valve operation.

BACKGROUND: In order to minimize surgical trauma, video-assisted mitral valve operation has been started using the Port-Access technique with the addition of a three-dimensional visualization system (Vista Cardiothoracic Systems Inc, Westborough, MA) and a voice-controlled camera-holding robotic arm (Aesop; Computer Motion Inc, Goleta, CA). METHODS: Port-Access mitral valve replacement or repair (PAMVR) was undertaken using an endovascular cardiopulmonary bypass (CPB) system. Fifty patients underwent Port-Access mitral valve replacement or repair. A three-dimensional thoracoscope was inserted allowing complete three-dimensional projection of the mitral valve (Vista). In the last 20 patients, the camera was attached to a robotic arm (Aesop), which allowed stabilization and voice-activated movement of the camera. Mitral valve repair was performed in 26 patients, and the valve was replaced in 24 patients with a mechanical valve prosthesis. RESULTS: Median time of operation was 4.2 hours, aortic cross-clamp time 83 minutes, CPB time 125 minutes, intensive care unit stay 1.5 days and hospitalization 9.0 days. Three months follow-up was complete in 40 patients, with 34 patients (85%) in New York Heart Association class I and 6 patients in class II. Mortality was 0% and rate of reoperation was 2%, with a follow-up time up to 1.5 years postoperatively. CONCLUSIONS: Using three-dimensional video and robotic assistance, it was possible to minimize the length of skin incision, but at the same time to optimally visualize the whole mitral valve apparatus in order to perform true Port-Access mitral valve operation, including various repair techniques.

Adult↗

Particulate emboli capture by an intra-aortic filter device during cardiac surgery.

OBJECTIVE: Particulate embolization is associated with neurologic morbidity after cardiac surgery. Crossclamp manipulation has been identified as the single most significant cause of particulate emboli release during cardiac surgery. A new intra-aortic filtration method has been assessed with regard to its safety and its ability to capture particulate emboli before they enter the central circulation. METHODS: Patients undergoing cardiac surgery with cardiopulmonary bypass through standard median sternotomy were selected for emboli management by means of intra-aortic filtration. A novel intra-aortic filter device was inserted through a modified 24F arterial cannula immediately before releasing the crossclamp in 77 patients. Filters remained in the aorta until cardiopulmonary bypass was discontinued and the heart was fully ejecting. The procedure was assessed for facility, safety, and effect on routine cardiopulmonary bypass operation and function. RESULTS: The insertion and removal of the intra-aortic filter were safe, easy, and uneventful in most patients. Patient hemodynamics and bypass flow rates remained normal throughout the filter dwell period. No strokes or gross neurologic defects were noted. Electron microscopic analysis of 12 filters revealed an insignificant degree of platelet adhesion on filter surfaces. Histology samples (n = 44) were examined, and 66% (n = 29) showed evidence of atheromatous material, 36% (n = 16) with platelet-fibrin, 25% (n = 11) with true thrombus and/or blood clot, 7% (n = 3) with normal vessel wall, and 2% (n = 1) with aggregates of cholesterol or grumous portion of atheromatous plaque. CONCLUSION: The intra-aortic filter can be safely deployed and captures particulate emboli, the predominant origin of which is atheromatous. The beneficial effects of this device on neurologic outcomes have yet to be determined.

Adult↗

Intermittent atrial level right-to-left shunt with temporary hypoxemia in a patient during support with a left ventricular assist device.

We report a 56-year-old male patient developing hypoxemia after surgical replacement of infected valves of a left ventricular assist device (LVAD, Novacor) which had supported him during the previous 15 months. Contrast transesophageal echocardiography (TEE) revealed an atrial septal defect with intermittent right-to-left shunt across a patent foramen ovale. We postulate that the shunt detected in this patient occurred as a consequence of reduced pulmonary vascular compliance due to positive end-expiratory pressure (PEEP) and an increase of mean intrathoracic pressure. Furthermore, we hypothesize that synchronized LVAD operation exacerbates any potential right-to-left shunt due to the profound left ventricular unloading which occurs during LVAD support. In this first report of a right-to-left shunt from a previously unrecognized patent foramen ovale in a Novacor patient, the subsequent transient hypoxemia could be managed by avoiding PEEP of more than 3 mmHg, and mean airway pressure of more than 11 mmHg and by careful volume replacement in order to prevent the pump from completely emptying the left ventricle (LV) and the left atrium (LA). Thus, prior to every LVAD implantation a transesophageal contrast echocardiography with Valsalva maneuver should be performed to identify intracardiac right-to-left shunt.

Heart Septal Defects, Atrial↗

Clinical use of a computer-enhanced surgical robotic system for endoscopic coronary artery bypass grafting on the beating heart.

The aim of the study was to perform endoscopic coronary artery bypass grafting on the beating heart using a surgical robotic system. In the study, the surgical system ZEUS was used in combination with 3D visualization for endoscopic coronary artery bypass grafting in 25 patients. In a total of 10 cases, the coronary artery anastomosis was done on the beating heart using endoscopic stabilizers without cardiopulmonary bypass. In all cases, total OR time ranged from 4.0 to 8.0 hours (median 5.5 h); the times for endoscopic coronary artery anastomoses ranged from 14 to 50 minutes (median 25 minutes) with no difference between arrested-heart or beating-heart procedures. All patients had an uneventful angiographic control result. An endoscopic coronary artery anastomosis is possible on the arrested as well as on the beating heart.

Cardiopulmonary Bypass↗